Effect of acetabular cup position on the contact mechanics of ceramic-on-ceramic hip joint replacements

被引:4
|
作者
Mak, MM [1 ]
Jin, ZM [1 ]
机构
[1] Univ Bradford, Sch Engn Design & Technol, Bradford BD7 1DP, W Yorkshire, England
来源
BIOCERAMICS 16 | 2004年 / 254-2卷
关键词
ceramic-on-ceramic; alumina; total hip arthroplasty; finite element analysis; contact mechanics;
D O I
10.4028/www.scientific.net/KEM.254-256.639
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The importance of the position of an alumina acetabular cup in close contact with an alumina femoral head was examined in this study using the finite element method. The effects of a wide range of inclination angles from 45degrees to 84degrees and anteversion angles from 0degrees to 25degrees were investigated on the predicted contact mechanics at the articulating surfaces. For the range of implantation angles considered in this study, no edge contact was observed at the rim of the acetabular cup, and the effect of the acetabular cup position on the predicted maximum contact pressure was found to be very small (less than 10%). These findings suggest that the edge contact and associated stripe wear observed clinically in ceramic-on-ceramic hip implants should be related to other mechanisms such as micro-separation, rather than to the position of the acetabular cup directly.
引用
收藏
页码:639 / 642
页数:4
相关论文
共 50 条
  • [21] Mid-term results of ceramic-on-ceramic total hip arthroplasty with sandwich cup
    Hasegawa, M
    Sudo, A
    Uchida, A
    BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 1357 - 1360
  • [22] FDA approves ceramic-on-ceramic hip
    不详
    AMERICAN CERAMIC SOCIETY BULLETIN, 2005, 84 (03): : 4 - 4
  • [23] Protrusion of acetabular screws as a cause of liner fracture in ceramic-on-ceramic total hip arthroplasty
    Natera Cisneros, L.
    Crusi, X.
    TRAUMA-SPAIN, 2014, 25 (01): : 37 - 39
  • [24] Ceramic-on-ceramic total hip replacement
    Riska, EB
    CURRENT ORTHOPAEDICS, 1999, 13 (04): : 320 - 324
  • [25] Delayed Diagnosis of Low-symptomatic Ceramic Acetabular Liner Fracture in Ceramic-on-Ceramic Total Hip Arthroplasty
    Regis, Dario
    Sandri, Andrea
    Bartolozzi, Pietro
    ORTHOPEDICS, 2008, 31 (10) : 1041 - 1041
  • [26] Functional orientation of the acetabular component in ceramic-on-ceramic total hip arthroplasty and its relevance to squeaking
    Pierrepont, J. W.
    Feyen, H.
    Miles, B. P.
    Young, D. A.
    Bare, J. V.
    Shimmin, A. J.
    BONE & JOINT JOURNAL, 2016, 98B (07): : 910 - 916
  • [27] Ceramic-on-ceramic total hip replacement system
    不详
    AMERICAN CERAMIC SOCIETY BULLETIN, 2003, 82 (04): : 23 - 23
  • [28] Design consideration to improve the acetabular cup of the ESKA-THR system by using the wear couple ceramic-on-ceramic
    Quack, G
    Willmann, G
    Krahl, H
    Grundei, H
    BIOMEDIZINISCHE TECHNIK, 1996, 41 (09): : 253 - 259
  • [29] Wear characteristics of ceramic-on-ceramic for hip endoprostheses
    Fruh, HJ
    Willmann, G
    Pfaff, HG
    BIOMATERIALS, 1997, 18 (12) : 873 - 876
  • [30] The Squeaking Hip: A Phenomenon of Ceramic-on-Ceramic Total Hip Arthroplasty
    Jarrett, Christopher A.
    Ranawat, Amar S.
    Bruzzone, Matteo
    Blum, Yossef C.
    Rodriguez, Jose A.
    Ranawat, Chitranjan S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06): : 1344 - 1349