Effect of acetabular cup position on the contact mechanics of ceramic-on-ceramic hip joint replacements

被引:4
|
作者
Mak, MM [1 ]
Jin, ZM [1 ]
机构
[1] Univ Bradford, Sch Engn Design & Technol, Bradford BD7 1DP, W Yorkshire, England
来源
BIOCERAMICS 16 | 2004年 / 254-2卷
关键词
ceramic-on-ceramic; alumina; total hip arthroplasty; finite element analysis; contact mechanics;
D O I
10.4028/www.scientific.net/KEM.254-256.639
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The importance of the position of an alumina acetabular cup in close contact with an alumina femoral head was examined in this study using the finite element method. The effects of a wide range of inclination angles from 45degrees to 84degrees and anteversion angles from 0degrees to 25degrees were investigated on the predicted contact mechanics at the articulating surfaces. For the range of implantation angles considered in this study, no edge contact was observed at the rim of the acetabular cup, and the effect of the acetabular cup position on the predicted maximum contact pressure was found to be very small (less than 10%). These findings suggest that the edge contact and associated stripe wear observed clinically in ceramic-on-ceramic hip implants should be related to other mechanisms such as micro-separation, rather than to the position of the acetabular cup directly.
引用
收藏
页码:639 / 642
页数:4
相关论文
共 50 条
  • [1] Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements
    Mak, MM
    Besong, AA
    Jin, ZM
    Fisher, J
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H6) : 403 - 408
  • [2] Analysis of contact mechanics in ceramic-on-ceramic hip joint replacements
    Mak, MM
    Jin, ZM
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H4) : 231 - 236
  • [3] Analysis of contact mechanics and lubrication in ceramic-on-ceramic hip joint replacements
    Mak, MM
    Jin, ZM
    BIOCERAMICS 14, 2002, 218-2 : 531 - 534
  • [4] Influence of Acetabular Cup Rim Design on the Contact Stress During Edge Loading in Ceramic-on-Ceramic Hip Prostheses
    Mak, Mathew
    Jin, Zhongmin
    Fisher, John
    Stewart, Todd D.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (01): : 131 - 136
  • [5] Total hip replacements with ceramic-on-ceramic bearings
    Milosev, Ingrid
    Trebse, Rihard
    Marjanovic, Benjamin
    Kovac, Simon
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2009, 78 : 41 - 48
  • [6] The role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip replacements
    Sexton, S. A.
    Yeung, E.
    Jackson, M. P.
    Rajaratnam, S.
    Martell, J. M.
    Walter, W. L.
    Zicat, B. A.
    Walter, W. K.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (04): : 439 - 442
  • [7] A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements
    Liu, Feng
    Feng, Li
    Wang, Junyuan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 83 : 135 - 142
  • [8] Finite Element Analysis of the Contact Mechanics of Ceramic-on-Ceramic Hip Resurfacing Prostheses
    Cilingir, Ahmet C.
    JOURNAL OF BIONIC ENGINEERING, 2010, 7 (03) : 244 - 253
  • [9] Finite element analysis of the contact mechanics of ceramic-on-ceramic hip resurfacing prostheses
    Ahmet C. Cilingir
    Journal of Bionic Engineering, 2010, 7 : 244 - 253
  • [10] Finite Element Analysis of the Contact Mechanics of Ceramic-on-Ceramic Hip Resurfacing Prostheses
    Ahmet C.Cilingir
    Journal of Bionic Engineering, 2010, 7 (03) : 244 - 253