摘要
Objective: To evaluate the safety of 3 Tesla (T) magnetic resonance imaging (MRI) in patients with auditory brainstem implants (ABI) with the magnet removed at implantation and report incidence of complications. Study Design: Retrospective chart review. Setting: Tertiary neurotology ambulatory practice. Patients: Patients with diagnosis of Neurofibromatosis, type 2 (NF2) with functional ABIs. Intervention(s): Observational recordings. Main Outcome Measure(s): Of the 89 patients meeting inclusion criteria, 7 patients underwent 3T MRI, with a total of 39 scans done. Three patients had 1 scan each, one patient had 4 scans, one patient had 5 scans, one patient had 6 scans, and one patient had 21 scans. The mean time between ABI placement and first 3 T scan was 118 +/- 73 months. The most common indication for imaging was surveillance of NF2 lesions. The most frequent scans were MRI brain (25.6%), followed by MRI of cervical (15%), thoracic (15%) and lumbar (15%) spine, and MRI IAC (8%). There were no reported complications for any of the scans. No scans were interrupted due to patient discomfort. There were no device malfunctions. Conclusions: 3 T MRIs are safe in patients with ABIs as long as the magnet is removed. It is recommended that the magnet be removed at the time of implantation in all NF2 patients, who require frequent surveillance.
引用
收藏
页码:E263 / E267
页数:5
相关论文
共 50 条
  • [21] Septal repair implants: evaluation of magnetic resonance imaging safety at 3 T
    Shellock, FG
    Valencerina, S
    MAGNETIC RESONANCE IMAGING, 2005, 23 (10) : 1021 - 1025
  • [22] 3 Tesla magnetic resonance imaging of the brain in newborns
    Gilmore, JH
    Zhai, GH
    Wilber, K
    Smith, JK
    Lin, WL
    Gerig, G
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2004, 132 (01) : 81 - 85
  • [23] Behaviour of Titanium Middle Ear Implants at 1.5 and 3 Tesla Field Strength in Magnetic Resonance Imaging
    Bauknecht, H. C.
    Jach, C.
    Krug, L.
    Schrom, T.
    LARYNGO-RHINO-OTOLOGIE, 2009, 88 (04) : 236 - 240
  • [24] Artefacts in 1.5 Tesla and 3 Tesla cardiovascular magnetic resonance imaging in patients with leadless cardiac pacemakers
    Daniel Kiblboeck
    Christian Reiter
    Juergen Kammler
    Pierre Schmit
    Hermann Blessberger
    Joerg Kellermair
    Franz Fellner
    Clemens Steinwender
    Journal of Cardiovascular Magnetic Resonance, 20
  • [25] Artefacts in 1.5 Tesla and 3 Tesla cardiac magnetic resonance imaging in patients with leadless cardiac pacemakers
    Kiblboeck, D.
    Reiter, C.
    Kammler, J.
    Schmit, P.
    Blessberger, H.
    Kellermair, J.
    Lukas, T.
    Kypta, A.
    Fellner, F.
    Steinwender, C.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 113 - 113
  • [26] Artefacts in 1.5 Tesla and 3 Tesla cardiovascular magnetic resonance imaging in patients with leadless cardiac pacemakers
    Kiblboeck, Daniel
    Reiter, Christian
    Kammler, Juergen
    Schmit, Pierre
    Blessberger, Hermann
    Kellermair, Joerg
    Fellner, Franz
    Steinwender, Clemens
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [27] Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla
    Martin, ET
    Coman, JA
    Shellock, FG
    Pulling, CC
    Fair, R
    Jenkins, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) : 1315 - 1324
  • [28] Auditory brainstem response and magnetic resonance imaging for acoustic neuromas - Costs by prevalence
    Robinette, MS
    Bauch, CD
    Olsen, WO
    Cevette, MJ
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2000, 126 (08) : 963 - 966
  • [29] Behavior of metal implants used in ENT surgery in 7 Tesla magnetic resonance imaging
    Thelen, Ariane
    Bauknecht, Hans-Christian
    Asbach, Patrick
    Schrom, Thomas
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2006, 263 (10) : 900 - 905
  • [30] Magnetic resonance imaging and cochlear implants: Compatibility and safety aspects
    Teissl, C
    Kremser, C
    Hochmair, ES
    Hochmair-Desoyer, IJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (01) : 26 - 38