Corneal iron deposits after laser in situ keratomileusis

被引:13
|
作者
Vongthongsri, A [1 ]
Chuck, RS [1 ]
Pepose, JS [1 ]
机构
[1] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
关键词
D O I
10.1016/S0002-9394(98)00301-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To report the occurrence and features of corneal iron line deposition after laser in situ keratomileusis (LASIK). METHODS: We evaluated 83 eyes undergoing LASIK. Corneal iron line deposition was analyzed with respect to preoperative spherical equivalent, attempted correction, and postoperative time interval. RESULTS: Thirty-five (42.2%) of 83 eyes displayed a distinctive brown-colored corneal iron line of variable density in a ring or patch configuration near the margin of the ablated zone in the overlying corneal flap epithelium, The appearance of this iron line correlated positively with time after surgery (>3 months) and preoperative spherical equivalent (>-4.5 diopters). CONCLUSIONS: Corneal iron line deposition in a ring or patch can be associated with previous LASIK surgery. This iron deposition within the margin of the ablated zone may offer insights into the dynamics of epithelial cell hyperplasia as well as basal cell proliferation. differentiation, and migration after LASIK. (C) 1999 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:85 / 86
页数:2
相关论文
共 50 条
  • [41] Posterior corneal surface changes after hyperopic laser in situ keratomileusis
    Ueda, T
    Nawa, Y
    Masuda, K
    Ishibashi, H
    Hara, Y
    Uozato, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11): : 2084 - 2087
  • [42] Slitlamp stretching of the corneal flap after laser in situ keratomileusis to reduce corneal striae
    Solomon, R
    Donnenfeld, ED
    Perry, HD
    Doshi, S
    Biser, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1292 - 1296
  • [43] Changes in posterior corneal elevation after laser in situ keratomileusis enhancement
    Vicente, Diego
    Clinch, Thomas E.
    Kang, Paul C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05): : 785 - 788
  • [44] Interface bonding with corneal crosslinking after laser in situ keratomileusis (LASIK)
    Kochevar, Irene E.
    Engler, Marleen
    Beck, Eric
    Seiler, Theo Gunther
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [45] Intracorneal rings to correct corneal ectasia after laser in situ keratomileusis
    Alió, L
    Salem, TF
    Artola, A
    Osman, AA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09): : 1568 - 1574
  • [46] Corneal changes after laser in situ keratomileusis: Measurement of corneal polarization magnitude and axis
    Angeles, R
    Abunto, T
    Bowd, C
    Zangwill, LM
    Schanzlin, DJ
    Weinreb, RN
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (04) : 697 - 703
  • [47] Correcting the Corneal Power Measurements after Myopic Laser In Situ Keratomileusis
    刘磊
    董洁玉
    李新宇
    华中科技大学学报(医学英德文版), 2006, (04) : 472 - 474
  • [48] Posterior corneal surface changes after laser in situ keratomileusis.
    Bruno, CR
    Roberts, CJ
    Castellano, D
    Mahmoud, A
    Birnbaum, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S605 - S605
  • [49] Time Course of Corneal Biomechanical Parameters after Laser in situ Keratomileusis
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Ohmoto, Fumiko
    OPHTHALMIC RESEARCH, 2009, 42 (03) : 167 - 171
  • [50] Corneal pharmacodynamics after photorefractive keratectomy and laser in situ keratomileusis in rabbits
    Maitchouk, D
    Smirennaia, E
    Kourenkov, V
    JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (03) : S382 - S384