Air source heat pump with water heater based on a bypass-cycle defrosting system using compressor casing thermal storage

被引:35
|
作者
Liu, Zhongbao [1 ,2 ]
Fan, Pengyan [1 ]
Wang, Qinghua [3 ]
Chi, Ying [1 ]
Zhao, Zhongqian [1 ]
Chi, Yuanying [2 ]
机构
[1] Beijing Univ Technol, Dept Refrigerat & Cryogen Engn, Coll Environm & Energy Engn, 100 Pingleyuan Rd, Beijing 100124, Peoples R China
[2] Being Univ Technol, Beijing Adv Innovat Ctr Future Internet Technol, 100 Pingleyuan Rd, Beijing 100124, Peoples R China
[3] Beijing Univ Technol, Sch Econ & Management, 100 Pingleyuan Rd, Beijing 100124, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Defrosting; Compressor casing; Heat storage; Phase change material; Heat pump; Bypass cycle; HOT GAS BYPASS; OUTDOOR COIL; PERFORMANCE; ENERGY; IMPROVEMENT; SIMULATION; UNIT;
D O I
10.1016/j.applthermaleng.2017.09.131
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the defrosting system of an air source heat pump utilizing compressor casing heat storage combined with a hot gas bypass cycle (ASHP-CCHS-HGBC) was designed. The phase change material for defrosting was selected, the phase change heat storage exchanger was devised, and the ASHP-CCHS-HGBC test system was established. The power consumption, defrosting time, and the influence of the indoor exchanger outlet on the air temperature in the ASHP-CCHS-HGBC method were then compared with those of the reverse-cycle defrosting (RCD) and electric heating defrosting (EHD) methods. Experimental results reveal that the total defrosting time and consumption of the ASHP-CCHS-HGBC method was 100 s and 43.6 kJ, respectively. These values were lower by 10 s (9%) and 12.1 kJ (21.7%) relative to those of RCD. Moreover, the compressor suction temperature was increased by 10.1 degrees C during defrosting by ASHP-CCHS-HGBC. Under the normal heating operation for 2.5 h, 10 L hot water with a temperature of 30 degrees C was obtained, the compressor casing temperature was reduced by 4.6 degrees C. While defrosting, the air temperature of the indoor heat exchanger outlet declined to only 3.3 degrees C and exerted the least influence on the indoor temperature among those of the three defrosting methods. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1420 / 1429
页数:10
相关论文
共 50 条
  • [31] Exergy Analysis of Air-source Heat Pump Water Heater
    Mi Bingjie
    Luo Qinghai
    Chen Guojie
    PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, 2016, 43 : 197 - 202
  • [32] Performance and defrosting effect study on the air-to-water heat pump with heat storage device
    Wang, Zhiyi
    Yang, Hongxing
    Huang, Hao
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2014, 9 (02) : 144 - 149
  • [33] Improving reverse cycle defrosting performance of air source heat pumps using thermal storage-based refrigerant sub-cooling energy
    Dong Jiankai
    Jiang Yiqiang
    Deng Shiming
    Yao Yang
    Qu Minglu
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2012, 33 (02): : 223 - 236
  • [34] The optimal defrosting condition of an air source heat pump based on entropy analysis
    Dong, Wei
    Li, Yongcun
    Zou, Shenghua
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 13176 - 13195
  • [35] Analysis On The Operating Characteristics Of Solar Water Heater In Combination With Air Source Heat Pump Water Heater
    Jiang Ai-guo
    Wang Xiao-zhong
    BIOTECHNOLOGY, CHEMICAL AND MATERIALS ENGINEERING, PTS 1-3, 2012, 393-395 : 601 - 603
  • [36] Performance analysis on parallel condensing air-source heat pump water heater system
    Wang, Shouchuan
    Wang, Qianxu
    Zhang, Huan
    Wang, Yuxuan
    Zhou, Junhai
    Zhao, Panpan
    Liu, Jiabao
    ENERGY REPORTS, 2022, 8 : 398 - 414
  • [37] A novel thermal energy storage based reversed-cycle defrosting technology for Air-to-air heat pumps
    Hu, W. J.
    Jiang, Y. Q.
    Han, Z. T.
    Yao, Y.
    Ma, Z. L.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 755 - 759
  • [38] Transient behavior and dynamic performance of cascade heat pump water heater with thermal storage system
    Wu, Jianghong
    Yang, Zhaoguang
    Wu, Qinghao
    Zhu, Yujuan
    APPLIED ENERGY, 2012, 91 (01) : 187 - 196
  • [39] Comparison of dynamic characteristics between the hot-gas bypass defrosting method and reverse-cycle defrosting method on an air-to-water heat pump
    Huang, Dong
    Yuan, Xiuling
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2006, 40 (05): : 539 - 543
  • [40] Defrosting characteristics and energy consumption of new air-water dual source composite heat pump system
    Xu J.
    Zhao Y.
    Quan Z.
    Wang H.
    Zhao H.
    Wang J.
    Zhao, Yaohua (yhzhao29@126.com), 2018, Materials China (69): : 2646 - 2654