Air source heat pump with water heater based on a bypass-cycle defrosting system using compressor casing thermal storage

被引:35
|
作者
Liu, Zhongbao [1 ,2 ]
Fan, Pengyan [1 ]
Wang, Qinghua [3 ]
Chi, Ying [1 ]
Zhao, Zhongqian [1 ]
Chi, Yuanying [2 ]
机构
[1] Beijing Univ Technol, Dept Refrigerat & Cryogen Engn, Coll Environm & Energy Engn, 100 Pingleyuan Rd, Beijing 100124, Peoples R China
[2] Being Univ Technol, Beijing Adv Innovat Ctr Future Internet Technol, 100 Pingleyuan Rd, Beijing 100124, Peoples R China
[3] Beijing Univ Technol, Sch Econ & Management, 100 Pingleyuan Rd, Beijing 100124, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Defrosting; Compressor casing; Heat storage; Phase change material; Heat pump; Bypass cycle; HOT GAS BYPASS; OUTDOOR COIL; PERFORMANCE; ENERGY; IMPROVEMENT; SIMULATION; UNIT;
D O I
10.1016/j.applthermaleng.2017.09.131
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the defrosting system of an air source heat pump utilizing compressor casing heat storage combined with a hot gas bypass cycle (ASHP-CCHS-HGBC) was designed. The phase change material for defrosting was selected, the phase change heat storage exchanger was devised, and the ASHP-CCHS-HGBC test system was established. The power consumption, defrosting time, and the influence of the indoor exchanger outlet on the air temperature in the ASHP-CCHS-HGBC method were then compared with those of the reverse-cycle defrosting (RCD) and electric heating defrosting (EHD) methods. Experimental results reveal that the total defrosting time and consumption of the ASHP-CCHS-HGBC method was 100 s and 43.6 kJ, respectively. These values were lower by 10 s (9%) and 12.1 kJ (21.7%) relative to those of RCD. Moreover, the compressor suction temperature was increased by 10.1 degrees C during defrosting by ASHP-CCHS-HGBC. Under the normal heating operation for 2.5 h, 10 L hot water with a temperature of 30 degrees C was obtained, the compressor casing temperature was reduced by 4.6 degrees C. While defrosting, the air temperature of the indoor heat exchanger outlet declined to only 3.3 degrees C and exerted the least influence on the indoor temperature among those of the three defrosting methods. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1420 / 1429
页数:10
相关论文
共 50 条
  • [1] Performance of bypass cycle defrosting system using compressor casing thermal storage for air-cooled household refrigerators
    Liu, Zhongbao
    Zhao, Fei
    Zhang, Lingfei
    Zhang, Ran
    Yuan, Meng
    Chi, Yuanying
    APPLIED THERMAL ENGINEERING, 2018, 130 : 1215 - 1223
  • [2] Improving defrosting performance of cascade air source heat pump using thermal energy storage based reverse cycle defrosting method
    Qu Minglu
    Li Tianrui
    Deng Shiming
    Fan Yanan
    Li Zhao
    APPLIED THERMAL ENGINEERING, 2017, 121 : 728 - 736
  • [3] An Experimental Study on the Improvement of Reverse Cycle Defrosting Performances for a Cascade Air Source Heat Pump using Thermal Energy Storage Based Defrosting Method
    Qu, Minglu
    Qin, Ruifeng
    Tang, Yongbo
    Fan, Yanan
    Li, Tianrui
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 818 - 825
  • [4] Analysis of Air-Source Heat Pump System Based on Energy Storage for Defrosting
    Liu, Xuelai
    Zhang, Hongrui
    Wang, Lei
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [5] A novel defrosting method using heat energy dissipated by the compressor of an air source heat pump
    Long, Zhang
    Dong Jiankai
    Jiang Yiqiang
    Yang, Yao
    APPLIED ENERGY, 2014, 133 : 101 - 111
  • [6] Experimental investigation on the hot gas bypass defrosting in air source transcritical CO2 heat pump water heater
    Wang, Yikai
    Ye, Zuliang
    Song, Yulong
    Yin, Xiang
    Cao, Feng
    APPLIED THERMAL ENGINEERING, 2020, 178
  • [7] Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump
    Dong Jian-kai
    Jiang Yi-qiang
    Yao Yang
    Zhang Xue-dan
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2011, 18 (06): : 2163 - 2169
  • [8] Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump
    Jian-kai Dong
    Yi-qiang Jiang
    Yang Yao
    Xue-dan Zhang
    Journal of Central South University of Technology, 2011, 18 : 2163 - 2169
  • [9] Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump
    董建锴
    姜益强
    姚杨
    张雪丹
    Journal of Central South University of Technology, 2011, 18 (06) : 2163 - 2169
  • [10] Experimental analysis of an air-source transcritical CO2 heat pump water heater using the hot gas bypass defrosting method
    Hu, Bin
    Wang, Xiaolin
    Cao, Feng
    He, Zhilong
    Xing, Ziwen
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 528 - 535