A novel loop-mediated isothermal amplification method for efficient and robust detection of EGFR mutations

被引:9
|
作者
Horiuchi, Sho [1 ,2 ]
Saito, Yuichi [2 ,3 ]
Matsui, Atsuka [4 ]
Takahashi, Nobumasa [3 ]
Ikeya, Tomohiko [3 ]
Hoshi, Eishin [3 ]
Shimizu, Yoshihiko [5 ]
Yasuda, Masanori [1 ]
机构
[1] Saitama Med Univ, Dept Pathol, Int Med Ctr, Hidaka 3501298, Japan
[2] Saitama Cardiovasc & Resp Ctr, Dept Thorac Surg, 1696 Itai, Kumagaya, Saitama 3600197, Japan
[3] Teikyo Univ, Dept Surg, Sch Med, Tokyo 1738605, Japan
[4] Eiken Chem Co Ltd, Fundamental Technol Res Dept, Fundamental Res Lab, Otawara, Tochigi 3240036, Japan
[5] Saitama Cardiovasc & Resp Ctr, Dept Pathol, Kumagaya, Saitama 3600197, Japan
关键词
EGFR; LAMP; NSCLC; adenocarcinoma; PCR; CELL LUNG-CANCER; GROWTH-FACTOR RECEPTOR; SENSITIVE DETECTION; PCR KIT; CLASSIFICATION; GEFITINIB; DIAGNOSIS; SURVIVAL; ASSAY;
D O I
10.3892/ijo.2020.4961
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The activation of somatic mutations conferring sensitivity to epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors has been widely used in the development of advanced or metastatic primary lung cancer therapy. Therefore, identification of EGFR mutations is essential. In the present study, a loop-mediated isothermal amplification (LAMP) method was used to identify EGFR mutations, and its efficiency was compared with the Therascreen quantitative PCR assay. Using LAMP and Therascreen to analyze surgically resected tissue samples from patients with pulmonary adenocarcinoma, EGFR mutations were observed in 32/59 tumor samples (LAMP) and 33/59 tumor samples (Therascreen). Notably, the LAMP assay identified one tumor as wild-type, which had previously been identified as a deletion mutation in exon 19 via the Therascreen assay (Case X). However, the direct sequencing to confirm the EGFR status of the Case X adhered to the results of the LAMP assay. Further experiments using Case X DNA identified this exon 19 deletion mutation using both methods. In addition, a novel deletion mutation in exon 19 of the EGFR was identified. Overall, the present study shows that the LAMP method may serve as a valuable alternative for the identification oncogene mutations.
引用
收藏
页码:743 / 749
页数:7
相关论文
共 50 条
  • [31] Novel Application of Loop-mediated Isothermal Amplification for Rapid Detection of Gene Translocation
    Matsuzaki, Ibu
    Iguchi, Hideto
    Mikasa, Yurina
    Morishita, Hiromu
    Okuda, Katsuya
    Nakaguchi, Keita
    Mori, Yuki
    Iwahashi, Yoshifumi
    Warigaya, Kenji
    Fujimoto, Masakazu
    Kojima, Fumiyoshi
    Murata, Shin-ichi
    ACTA HISTOCHEMICA ET CYTOCHEMICA, 2017, 50 (06) : 169 - 176
  • [32] Loop-mediated isothermal amplification (LAMP): A novel rapid detection platform for pathogens
    Li, Yanmei
    Fan, Penghui
    Zhou, Shishui
    Zhang, Li
    MICROBIAL PATHOGENESIS, 2017, 107 : 54 - 61
  • [33] A Novel Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Yersinia pestis
    Bai, Ying
    Rizzo, Maria Rosales
    Parise, Christina
    Maes, Sarah
    Eisen, Rebecca J.
    FRONTIERS IN MICROBIOLOGY, 2022, 13
  • [34] Detection of capripoxvirus DNA using a novel loop-mediated isothermal amplification assay
    Murray, Lee
    Edwards, Lorraine
    Tuppurainen, Eeva S. M.
    Bachanek-Bankowska, Katarzyna
    Oura, Chris A. L.
    Mioulet, Valerie
    King, Donald P.
    BMC VETERINARY RESEARCH, 2013, 9
  • [35] Evaluation of loop-mediated isothermal amplification for the rapid, reliable, and robust detection of Salmonella in produce
    Yang, Qianru
    Wang, Fei
    Jones, Kelly L.
    Meng, Jianghong
    Prinyawiwatkul, Witoon
    Ge, Beilei
    FOOD MICROBIOLOGY, 2015, 46 : 485 - 493
  • [36] A simple and sensitive method for detection of Bacillus anthracis by loop-mediated isothermal amplification
    Kurosaki, Y.
    Sakuma, T.
    Fukuma, A.
    Fujinami, Y.
    Kawamoto, K.
    Kamo, N.
    Makino, S.-I.
    Yasuda, J.
    Journal of Applied Microbiology, 2009, 107 (06): : 1947 - 1956
  • [37] Sensitive and Rapid Detection of Edwardsiellosis in Fish by a Loop-Mediated Isothermal Amplification Method
    Savan, Ram
    Igarashi, Arisa
    Matsuoka, Satoru
    Sakai, Masahiro
    Appl. Environ. Microbiol., 1 (621-624):
  • [38] Detection of Mycobacteriosis in guppy, Poecilia reticulata, by loop-mediated isothermal amplification method
    Ponpornpisit, A.
    Areechon, N.
    Kono, T.
    Kitao, Y.
    Sakai, M.
    Katagiri, T.
    Endo, M.
    BULLETIN OF THE EUROPEAN ASSOCIATION OF FISH PATHOLOGISTS, 2009, 29 (01): : 3 - 9
  • [39] Rapid detection of mecA and spa by the loop-mediated isothermal amplification (LAMP) method
    Koide, Y.
    Maeda, H.
    Yamabe, K.
    Naruishi, K.
    Yamamoto, T.
    Kokeguchi, S.
    Takashiba, S.
    LETTERS IN APPLIED MICROBIOLOGY, 2010, 50 (04) : 386 - 392
  • [40] Development of a real time loop-mediated isothermal amplification method for detection of Senecavirus A
    Zeng, Fanwen
    Cong, Feng
    Liu, Xiangnan
    Lian, Yuexiao
    Wu, Miaoli
    Xiao, Li
    Yuan, Wen
    Huang, Ren
    Ma, Jingyun
    Guo, Pengju
    Luo, Manlin
    JOURNAL OF VIROLOGICAL METHODS, 2018, 261 : 98 - 103