Nickel-functionalized reduced graphene oxide with polyaniline for non-enzymatic glucose sensing

被引:47
|
作者
Zhang, Bing [1 ]
He, Yu [1 ]
Liu, Bingqian [1 ]
Tang, Dianping [1 ]
机构
[1] Fuzhou Univ, Inst Nanomed & Nanobiosensing, Dept Chem, Fuzhou 350108, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-enzymatic sensing; Glucose; Reduced graphene oxide; Polyaniline; Nickel metal nanostructure; NANOSTRUCTURES; NANOCOMPOSITE; SENSORS;
D O I
10.1007/s00604-014-1366-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a new class of organic-inorganic hybrid nanostructures based on the use of reduced graphene oxide (rGO), polyaniline, and a nickel metal nanostructure. It was applied to efficient non-enzymatic sensing of glucose based on its electrocatalytic oxidation. Scanning electron microscopy and energy-dispersive X-Ray were employed to characterize the material. It is shown that the doped polyaniline plays an important role in the formation of the hybrid nanostructures. Improved analytical performance is found when the hybrid nanostructures were placed on a glassy carbon electrode and used for non-enzymatic sensing of glucose at a typical working potential of +450 mV and a pH value of 13. Features include a fast response (similar to 2 s), high sensitivity (6,050 mu A mM(-1) cm(-2)), a linear range from 0.1 mu M to 1.0 mM, and a low detection limit (0.08 mu M). The response to glucose follows a Michaelis-Menten kinetic behavior, and the K (M) value was determined to be 0.241 mu M. Reproducibility and specificity are acceptable. Fructose and maltose do not interfere significantly. Importantly, the methodology was validated and evaluated for the analysis of 15 spiked human serum specimens, receiving in a good accordance with the results obtained by the non-enzymatic glucose sensing and the commercialized personal glucose meter.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [31] Palladium–Nickel nanoparticles decorated on Functionalized-MWCNT for high precision non-enzymatic glucose sensing
    Karimi-Maleh, Hassan
    Cellat, Kemal
    Arıkan, Kubilay
    Savk, Aysun
    Karimi, Fatemeh
    Şen, Fatih
    Materials Chemistry and Physics, 2020, 250
  • [32] Non-enzymatic Amperometric Glucose Sensor Based on Copper Nanowires Decorated Reduced Graphene Oxide
    Ju, Lele
    Wu, Guosong
    Lu, Biao
    Li, Xiaoyun
    Wu, Huaping
    Liu, Aiping
    ELECTROANALYSIS, 2016, 28 (10) : 2543 - 2551
  • [33] A non-enzymatic glucose sensor based on the CuS nanoflakes-reduced graphene oxide nanocomposite
    Yan, Xiaoyi
    Gu, Yue
    Li, Cong
    Zheng, Bo
    Li, Yaru
    Zhang, Tingting
    Zhang, Zhiquan
    Yang, Ming
    ANALYTICAL METHODS, 2018, 10 (03) : 381 - 388
  • [34] Palladium nanoparticles on electrochemically reduced chemically modified graphene oxide for non-enzymatic bimolecular sensing
    Hossain, M. F.
    Park, Jae Y.
    RSC ADVANCES, 2013, 3 (36): : 16109 - 16115
  • [35] Preparation of reduced graphene oxide-Ni(OH)2 composites by electrophoretic deposition: application for non-enzymatic glucose sensing
    Subramanian, Palaniappan
    Niedziolka-Jonsson, Joanna
    Lesniewski, Adam
    Wang, Qian
    Li, Musen
    Boukherroub, Rabah
    Szunerits, Sabine
    JOURNAL OF MATERIALS CHEMISTRY A, 2014, 2 (15) : 5525 - 5533
  • [36] Preparation of reduced graphene oxide-Ni(OH)2 composites by electrophoretic deposition: application for non-enzymatic glucose sensing
    Subramanian, Palaniappan
    Niedziolka-Jonsson, Joanna
    Lesniewski, Adam
    Wang, Qian
    Li, Musen
    Boukherroub, Rabah
    Szunerits, Sabine
    JOURNAL OF MATERIALS CHEMISTRY A, 2024,
  • [37] Nitrogen-Enriched Sulfur-Functionalized Reduced Graphene Oxide Nanosheets for Non-Enzymatic Uric Acid Sensing and Supercapacitor Application
    Lavanya, J.
    Aakash, M.
    Srinivasan, R.
    Sankar, A. Ravi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (01)
  • [38] Non-enzymatic electrochemical sensing of glucose
    Guangfeng Wang
    Xiuping He
    Lingling Wang
    Aixia Gu
    Yan Huang
    Bin Fang
    Baoyou Geng
    Xiaojun Zhang
    Microchimica Acta, 2013, 180 : 161 - 186
  • [39] Non-enzymatic electrochemical sensing of glucose
    Wang, Guangfeng
    He, Xiuping
    Wang, Lingling
    Gu, Aixia
    Huang, Yan
    Fang, Bin
    Geng, Baoyou
    Zhang, Xiaojun
    MICROCHIMICA ACTA, 2013, 180 (3-4) : 161 - 186
  • [40] Highly sensitive and reusable Cu+2/polyaniline/reduced graphene oxide nanocomposite ink-based non-enzymatic glucose sensor
    Anand, Vijay Kumar
    Bukke, Archana
    Bhatt, Kapil
    Kumar, Sandeep
    Sharma, Sandeep
    Goyal, Rakesh
    Virdi, G. S.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2020, 126 (07):