Efficacy and safety of transvenous lead extraction in the Chinese octogenarian patients

被引:2
|
作者
Zhou, Xu [1 ]
Ze, Feng [2 ]
Li, Xuebin [2 ]
Wang, Bin [1 ]
机构
[1] Shantou Univ, Med Coll, Affiliated Hosp 1, Dept Cardiol, Shantou, Guangdong, Peoples R China
[2] Peking Univ, Dept Cardiac Electrophysiol, Peoples Hosp, Beijing, Peoples R China
关键词
octogenarians; pacemaker; procedure outcomes; transvenous lead extraction; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; PACEMAKER; EXPERIENCE; OUTCOMES; TRENDS;
D O I
10.1002/clc.23629
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Managing elderly patients with infection or malfunction deriving from a cardiac implantable electronic device (CIED) may be challenging. We report the safety and effectiveness of transvenous lead extraction in Chinese octogenarian patients. Hypothesis Transvenous lead extraction can be performed safely and successfully in the Chinese octogenarians. Methods We retrospectively identified all patients who underwent TLE at our institution between March 2013 and January 2021. This population was divided into the following two groups based solely on age: octogenarians and non-octogenarians. These two groups were compared on the basis of several characteristics and clinical outcomes. Results Consecutive 1106 patients were analyzed, including 184 (16.6%) octogenarians and 922(83.4%) non-octogenarians. The octogenarians presented more comorbidities. A total of 378 leads and 2004 leads were removed from the patients in the octogenarian group and non-octogenarian group, respectively. The mean lead implant duration was 6.1 +/- 5.1 and 5.8 +/- 4.6 years for octogenarians and non-octogenarians (p = 0.296). The majority of the patients in both groups underwent TLE through the femoral approach (67.5% vs 61.6%, p = 0.14). The complete procedure success rate was similar between the octogenarian and non-octogenarian group (96.7% vs.95.3%, p = 0.39). There were no differences with respect to the proportion of minor, major complications and deaths. Long-term mortality (median time 3.3 years) after TLE in octogenarians was significantly higher compared with younger individuals. Conclusions At experienced centers, transvenous lead extraction can be performed safely in Chinese octogenarians with procedural success rate and complication rate comparable to younger individuals.
引用
收藏
页码:971 / 977
页数:7
相关论文
共 50 条
  • [21] Initial experience with the Tightrail rotating mechanical dilator sheath for transvenous lead extraction: safety and efficacy
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Sahiner, M. L.
    Kaya, E. B.
    Evranos, B.
    Ozer, N.
    EUROPEAN HEART JOURNAL, 2015, 36 : 821 - 822
  • [22] Transvenous lead extraction
    Tofield, A.
    EUROPEAN HEART JOURNAL, 2017, 38 (32) : 2457 - 2458
  • [23] SAFETY OF SAME DAY DISCHARGE AFTER TRANSVENOUS LEAD EXTRACTION
    Van Hon, Logan
    Latanich, Chris
    Catherine, Benziger
    Groth, Nicole
    Ross, Lauren
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 220 - 220
  • [24] Safety and Efficacy of Transvenous Lead Extraction With a High-Frequency Excimer Laser - A Single Center Experience -
    Yoshitake, Takakatsu
    Goya, Masahiko
    Sasaki, Takeshi
    Shiohira, Shinya
    Sekigawa, Masahiro
    Shirai, Yasuhiro
    Lee, Kiko
    Yagishita, Atsuhiko
    Maeda, Shingo
    Takahashi, Yoshihide
    Kawabata, Mihoko
    Hirao, Kenzo
    CIRCULATION JOURNAL, 2018, 82 (12) : 2992 - 2997
  • [25] How adequate are the current methods of lead extraction? A review of the efficiency and safety of transvenous lead extraction methods
    Buiten, Maurits S.
    van der Heijden, Aafke C.
    Schalij, Martin J.
    van Erven, Lieselot
    EUROPACE, 2015, 17 (05): : 689 - 700
  • [26] Transvenous lead extraction clinically successful in 98% of patients
    Tofield, Andros
    EUROPEAN HEART JOURNAL, 2015, 36 (02) : 68 - 68
  • [27] Laser Lead Extraction in the Octogenarian Patient
    Rodriguez, Yasser
    Garisto, Juan D.
    Carrillo, Roger G.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (05): : 719 - 723
  • [28] Efficacy and safety of the new TightRail (TM) mechanical sheath for transvenous lead extraction: Results of a French multicenter study
    Artus, Adrien
    Mansourati, Jacques
    Fatemi, Marjaneh
    Pierre, Bertrand
    Schatz, Alexandre
    Badoz, Marc
    Laurent, Gabriel
    Guenancia, Charles
    Garnier, Fabien
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (04) : 731 - 737
  • [29] Efficacy and Safety of Transvenous Lead Extraction in the Device Laboratory and Operating Room Guided by a Novel Risk Stratification Scheme
    Kancharla, Krishna
    Acker, Nancy G.
    Li, Zhuo
    Samineni, Swetha
    Cai, Cheng
    Espinosa, Raul E.
    Osborn, Michael
    Mulpuru, Siva K.
    Asirvatham, Samuel J.
    Friedman, Paul A.
    Cha, Yong-Mei
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (02) : 174 - 182
  • [30] The challenges of transvenous lead extraction
    Maytin, Melanie
    Epstein, Laurence M.
    HEART, 2011, 97 (05) : 425 - 434