摘要
SF6 is a greenhouse gas. Finding an alternative gas for SF6 has become an urgent problem in the switch field. In order to explore the feasibility of replacing SF6 gas with dry air directly, CO2 and C4F7N/CO2 mixed gas, based on the KYN28-12 medium voltage switchgear, the finite element method was used to solve the three-dimensional coupled multi-physics of the switchgear in this paper. From the angle of the temperature field and flow field, the temperature rise characteristics under different operation conditions were analyzed. The results showed that the temperature field and flow field distribution under the four gases were similar. Among them, the temperature rise of SF6 gas was the smallest, followed by the C4F7N/CO2 mixed gas, CO2 and dry air. The flow rate of SF6 gas was the lowest, about 0.11 m/s. The flow velocities of other gases were relatively close. When the switchgear was filled with the same gas, as the inflation pressure increased, the temperature rise of the switchgear decreased and the gas flow rate also dropped to a certain extent. The temperature field and flow field of the switchgear under the C4F7N/CO2 mixed gas at 0.2 Mpa were similar to those under the 0.1 Mpa SF6 gas. Under the C4F7N/CO2 mixed gas, the contact failure of the plum contact made the temperature rise of the switchgear increase overall. The maximum temperature rise point transferred to the contact failure. The temperature rise further rose with the increase of the contact failure degree. The gas flow rate also greatly increased with the failure degree elevated. From the perspective of temperature rise, the C4F7N/CO2 mixed gas has the possibility of being applied in the electrical equipment under the premise of meeting the insulation conditions. (c) 2022 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
引用
收藏
页码:654 / 664
页数:11
相关论文
共 50 条
  • [31] Experimental Investigation of Typical Partial Discharge Signals in Medium-voltage Switchgear
    Wang, L. J.
    Ning, W. J.
    Wu, C.
    Wang, L. H.
    Wang, H. J.
    Jia, S. L.
    Lu, H.
    PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 393 - 396
  • [32] Medium-Voltage Arc Flash in Switchgear and Live-Front Transformers
    Eblen, M. L.
    Short, T. A.
    Lee, W. -J.
    2016 IEEE IAS ELECTRICAL SAFETY WORKSHOP (ESW), 2016, : 100 - 109
  • [33] Medium-Voltage Arc Flash in Switchgear and Live-Front Transformers
    Eblen, Marcia L.
    Short, Tom A.
    Lee, Wei-Jen
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (06) : 5280 - 5288
  • [34] INDACTIC MASA FOR REMOTE-CONTROL OF SWITCHGEAR IN MEDIUM-VOLTAGE SYSTEMS
    PREMUR, K
    BROWN BOVERI REVIEW, 1978, 65 (05): : 334 - 336
  • [35] On-site Online Condition Monitoring of Medium-Voltage Switchgear Units
    Nicolaou, Christina
    Mansour, Ahmad
    Van Laerhoven, Kristof
    11TH INTERNATIONAL CONFERENCE ON THE INTERNET OF THINGS, IOT 2021, 2021, : 1 - 8
  • [36] MEDIUM-VOLTAGE SWITCHGEAR INSTALLATIONS USING AIRBLAST AND MAGNETBLAST CIRCUIT-BREAKERS
    POOLE, D
    MUNZINGER, K
    BROWN BOVERI REVIEW, 1975, 62 (04): : 160 - 164
  • [37] Thermal Analyses for a Simplified Medium-Voltage Switchgear: Numerical and Experimental Benchmark Studies
    Seker, Ahmet Efe
    Sakaci, Egemen Aslan
    Deniz, Arif
    Celik, Bayram
    Yildirim, Deniz
    2019 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO 2019), 2019, : 116 - 120
  • [38] IEC Versus IEEE/ANSI Medium-Voltage Switchgear: Matching the Standard to the Application
    Webb, John C.
    Neighbours, Terry
    Karandikar, Harshavardhan
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2022, 28 (01) : 65 - 75
  • [39] Sulphur hexafluoride in modern medium-voltage switchgear: Advantages, hazards and environmental impact
    Boskovic, Aleksandar
    Sremacki, Maja
    Vjestica, Suncica
    Cavic, Aleksandra
    Markovic, Nada
    Borovac, Branislav
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2024, 89 (05) : 693 - 704
  • [40] Estimate the Temperature Rise of Medium Voltage Metal Enclosed Switchgear by Simplified Heat Transfer Calculations
    Fjeld, Elin
    Rondeel, Wilhelm G. J.
    Attar, Elham
    Singh, Shailendra
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (02) : 853 - 860