The influence of the thickness of an aluminium radiant sheet on the performance of the lightweight floor heating

被引:17
|
作者
Werner-Juszczuk, Anna Justyna [1 ]
机构
[1] Bialystok Tech Univ, Heating Ventilat, Air Conditioning Dept, Wiejska 45E, PL-15351 Bialystok, Poland
来源
关键词
Radiant floor; Aluminium radiant sheet; Dry floor heating system; Lightweight floor heating; Numerical study; SURFACE-TEMPERATURE; NUMERICAL-ANALYSIS; SYSTEM; UNDERFLOOR; BUILDINGS; MODEL; PUMP;
D O I
10.1016/j.jobe.2021.102896
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of this work is to determine the optimal thickness of aluminium radiant sheet in the lightweight floor heating, i.e. the smallest thickness of the aluminium, ensuring high efficiency and thermal comfort. The optimal operational and construction parameters are determined regards to the aluminium thickness. Finding the optimal aluminium thickness is important for economic and ecological reasons: less aluminium thickness, less aluminium consumption and less cost of construction. Numerical calculations were performed with ANSYS Steady-State Thermal Solver (Workbench 19.2) for floor heating with a dry screed, wood-like board and pipes embedded in the layer of tile adhesive. The influence of aluminium thickness changes in the range of 0.1-0.5 mm was analysed for variable water temperature, pipe spacing and constructions. The optimal aluminium radiant sheet thickness is 0.3 mm, 0.1 mm is not recommended. The optimal water temperature is 25-35 degrees C, 45 degrees C is not recommended. Constructions with a dry screed 25 mm thick should not be used. Constructions with pipes in tile adhesive should be used at a water temperature of 25-30 degrees C and an aluminium thickness of 0.3-0.5 mm. Constructions with wood-like board should be used at a water temperature of 25-35 degrees C and an aluminium of 0.3-0.4 mm. Results enable a conscious choice of such constructions and operational parameters of lightweight floor heating that ensure high efficiency, thermal comfort and low investment costs. The work includes the original specification of the lightweight floor heating efficiency depending on the radiant sheet thickness and specifies recommended radiant sheet thicknesses.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Thermal performance analysis of concrete embedded plastic radiant floor heating
    Zong, Lihua
    Zhongguo Jishui Paishui/China Water & Wastewater, 2000, 16 (02): : 6 - 8
  • [22] Investigation of thermal performance of a passive solar building with floor radiant heating
    Athienitis, AK
    SOLAR ENERGY, 1997, 61 (05) : 337 - 345
  • [23] Partition Heating Performance of Radiant Floor System in Railway Stations on Plateau
    Zheng J.
    Yu T.
    Lei B.
    Chen C.
    Lyu R.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2024, 59 (01): : 62 - 69
  • [24] Study on predicting the radiant heat flow rate of floor surface of radiant floor heating
    Lu, Lidi
    Luo, Lulin
    Chen, Jinhua
    ENERGY AND BUILDINGS, 2023, 301
  • [25] Thermal performance of a radiant floor heating system with different heat storage materials and heating pipes
    Zhou, Guobing
    He, Jing
    APPLIED ENERGY, 2015, 138 : 648 - 660
  • [26] Comfortable floor temperatures for radiant floor heating in Southern China
    Wu, Yuxin
    Liu, Hong
    Li, Baizhan
    Lu, Xingyu
    Chen, Lu
    Kosonen, Risto
    CHINESE SCIENCE BULLETIN-CHINESE, 2021, 66 (19): : 2476 - 2485
  • [27] Experimental Evaluation of the Thermal Performance of Raised Floor Integrated Radiant Heating Panels
    Kim, Dong-Woo
    Joe, Goo-Sang
    Park, Sang-Hoon
    Yeo, Myoung-Souk
    Kim, Kwang-Woo
    ENERGIES, 2017, 10 (10):
  • [28] Study on thermal performance of a PCM enhanced hydronic radiant floor heating system
    Larwa, Barbara
    Cesari, Silvia
    Bottarelli, Michele
    ENERGY, 2021, 225
  • [29] EXPERIMENTAL STUDY ON RADIANT FLOOR HEATING SYSTEM
    Ngo, C. C.
    Alhabeeb, B. A.
    Balestrieri, M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 8A, 2016,
  • [30] Numerical simulation of module radiant floor heating
    Zhang Zhi-hong
    Zhou Zhi-hua
    Pan Zhi-xin
    Ma Li-shan
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 245 - 248