A calculation of relative efficiencies of a GEM-based neutron detector using different solid neutron converters

被引:0
|
作者
Rittirong, A. [1 ]
Sripreeprem, S. [1 ]
Saenboonruang, K. [1 ]
机构
[1] Kasetsart Univ, Dept Appl Radiat & Isotopes, Fac Sci, Bangkok 10900, Thailand
来源
INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE 2016 | 2017年 / 860卷
关键词
D O I
10.1088/1742-6596/860/1/012018
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A Gas Electron Multiplier (GEM) detector is one of the most promising particle detectors nowadays due to its excellences in high rates of detection capability, good spatial resolution, and flexibility in designs. In addition to typical applications of ionizing particle detection, the GEM detector could also be modified to detect thermal neutrons by coating suitable solid neutron converters to its GEM drift cathode. Although, wide selections of materials are available to be used as neutron converters, most suitable ones must have high neutron-absorption-cross-section properties as more chances of nuclear interactions between thermal neutrons and their nuclei are desirable. Another factor that plays important roles to detection efficiencies in addition to types of materials is thicknesses of coating layers. Although thicker layers mean higher numbers of nuclei available for interactions with neutrons, ionizing particles produced after the interactions have less chances of successfully penetrate thick layers to ionize gas molecules for detection. Consequently, an optimum thickness for each material is crucial for GEM-based thermal neutron detector and must be carefully determined. This article aims to illustrate in-depth calculations to find these optimum thicknesses and their corresponding relative efficiencies for different solid neutron converters including Li-6, Li-nat, B-10, B-nat, Cd-113, Cd-nat, Sm-149, and Sm-nat, using a simulation and actual data of GEM's properties. Basic information of GEM detector and neutron detection, simulations, efficiency calculations, results, and discussion will be thoroughly reported in this article.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] TPC-like readout for thermal neutron detection using a GEM-detector
    Flierl, B.
    Hertenberger, R.
    Biebel, O.
    Zeitelhack, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 528 - 531
  • [32] Properties of the neutron detector based on ionisation chamber with 6Li converters
    Engels, R
    Clemens, U
    Kemmerling, G
    Schelten, J
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 485 - 488
  • [33] Concept of a compact high-resolution neutron spectrometer based on GEM detector for fusion plasmas
    Schotz, M.
    Wiqcek, U.
    Drozdowicz, K.
    Jardin, A.
    Woznicka, U.
    Kurowski, A.
    Kulinska, A.
    Dabrowski, W.
    Lach, B.
    Mazon, D.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (05)
  • [34] Comparison of the performance of different converters for neutron radiography and tomography using fission neutrons
    Guo, Jimei
    Buecherl, Thomas
    Zou, Yubin
    Guo, Zhiyu
    Tang, Guoyou
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 605 (1-2): : 69 - 72
  • [35] Thermal neutron detection using a silicon pad detector and 6LiF removable converters
    Barbagallo, Massimo
    Cosentino, Luigi
    Forcina, Vittorio
    Marchetta, Carmelo
    Pappalardo, Alfio
    Peerani, Paolo
    Scire, Carlotta
    Scire, Sergio
    Schillaci, Maria
    Vaccaro, Stefano
    Vecchio, Gianfranco
    Finocchiaro, Paolo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (03):
  • [36] Application of fluorine-based threshold activation detector for neutron flux calculation from D-T neutron generator
    Sibczynski, Pawel
    Broslawski, Andrzej
    Burakowski, Szymon
    Chlopik, Arkadiusz
    Dryll, Marek
    Dziedzic, Andrzej
    Gierlik, Michal
    Grodzicki, Krystian
    Kazmierczak, Lukasz
    Krakowski, Tomasz
    Niechcielski, Kamil
    Rzadkiewicz, Jacek
    Sliphukin, Ivan
    Trela, Krystian
    Urban, Arkadiusz
    Zezulinski, Kacper
    Iovene, Alessandro
    Tintori, Carlo
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2019), 2020, 225
  • [37] A proposed boron-carbide-based solid-state neutron detector
    Emin, D
    Aselage, TL
    JOURNAL OF APPLIED PHYSICS, 2005, 97 (01)
  • [38] A proposed boron-carbide-based solid-state neutron detector
    Emin, David
    Aselage, T.L.
    Journal of Applied Physics, 2005, 97 (01):
  • [39] Neutron diffraction measurements on a reference metallic sample with a high-efficiency GEM side-on 10B-based thermal neutron detector
    Pietropaolo, A.
    Claps, G.
    Fedrigo, A.
    Grazzi, F.
    Hoglund, C.
    Murtas, F.
    Scherillo, A.
    Schmidt, S.
    Schooneveld, E. M.
    EPL, 2018, 121 (06)
  • [40] Physical-chemical characterization of a GEM side-on 10B-based thermal neutron detector and analysis of its neutron diffraction performances
    Santoni, A.
    Celentano, G.
    Claps, G.
    Fedrigo, A.
    Hoglund, C.
    Murtas, F.
    Rondino, F.
    Rufoloni, A.
    Scherillo, A.
    Schmidt, S.
    Vannozzi, A.
    Pietropaolo, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 906 : 83 - 87