Operational behavior characteristics and energy saving potential of vertical closed loop ground source heat pump system combined with storage tank in an office building

被引:22
|
作者
Kim, Min Ji [1 ]
Seo, Byeong Mo [2 ]
Lee, Jong Man [1 ]
Choi, Jong Min [3 ]
Lee, Kwang Ho [4 ]
机构
[1] Hanbat Natl Univ, Grad Sch, San 16-1, Daejeon 305719, South Korea
[2] North Carolina State Univ, Coll Design, 50 Pullen Rd,Campus Box 7701, Raleigh, NC 27695 USA
[3] Hanbat Natl Univ, Dept Mech Engn, San 16-1, Daejeon 305719, South Korea
[4] Hanbat Natl Univ, Dept Architectural Engn, San 16-1, Daejeon 305719, South Korea
关键词
Vertical Closed Loop Ground Source Heat; Pump (VGSHP); Part Load Ratio (PLR); Energyplus; Heat storage tank; Coefficient of Performance (COP); Performance curve;
D O I
10.1016/j.enbuild.2018.09.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A ground source heat pump (GSHP) system utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. Among various types of GSHP systems, Vertical Closed Loop Ground Source Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, in order to improve the system performance of a VGSHP, a VGSHP system coupled with heat storage tank was evaluated. For this purpose, the detailed analysis on the operational behavior of heat storage tank and the variations of heat pump energy performance due to the connection with heat storage tank was performed, and characteristics of heat pump part load ratios (PLRs) and the corresponding energy requirements, compared to chiller and boiler based conventional system, were analyzed in detail, using dynamic energy simulation after comprehensive validation process of heat pump performance curves. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 20% for cooling and about 77% for heating compared to the conventional air conditioning system, and an energy saving effect of about 2% for cooling and about 15% for heating compared to the VGSHP system without heat storage tank, mainly due to the fact that the operational pattern of heat pump such as PLR and COP characteristics was changed by the operation of heat storage tank. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 252
页数:14
相关论文
共 50 条
  • [41] The energy saving analysis of coupled water source heat pump system applied in campus building
    Zhao, Jing
    Zhu, Neng
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 348 - 354
  • [42] Integration of a Photovoltaic System with an Electric Heat Pump and Electrical Energy Storage Serving an Office Building
    Roselli, Carlo
    Tariello, Francesco
    Sasso, Maurizio
    JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2019, 7 (02): : 213 - 228
  • [43] INFLUENCES OF OPERATIONAL IMPROVEMENT ON GROUND TEMPERATURE AND ENERGY PERFORMANCE IN GROUND SOURCE HEAT PUMP SYSTEM IN WARM REGION
    Ide T.
    Kindaichi S.
    Nishina D.
    AIJ Journal of Technology and Design, 2023, 29 (71) : 280 - 285
  • [44] Discussion of a combined solar thermal and ground source heat pump system operation strategy for office heating
    Li, Huai
    Xu, Wei
    Yu, Zhen
    Wu, Jianlin
    Yu, Zhenyu
    ENERGY AND BUILDINGS, 2018, 162 : 42 - 53
  • [45] Performance and Potential Applications of Direct Expansion Ground Source Heat Pump Systems for Building Energy
    Omer, A.
    NANOTECHNOLOGY 2012, VOL 3: BIO SENSORS, INSTRUMENTS, MEDICAL, ENVIRONMENT AND ENERGY, 2012, : 665 - 668
  • [46] Long-Term Monitoring and Simulation of a Vertical Closed-Loop Ground Source Heat Pump System Used in the Cold Climate of the US
    Miao, Rui
    Yu, Yao
    Hu, Xiaoou
    Sirotiak, Todd
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 2, 2019, 125 : 347 - 355
  • [47] Demand Response Potential of an Educational Building Heated by a Hybrid Ground Source Heat Pump System
    Xue, Tianchen
    Jokisalo, Juha
    Kosonen, Risto
    ENERGIES, 2024, 17 (21)
  • [48] Energy pile-based ground source heat pump system with seasonal solar energy storage
    Ma, Qijie
    Fan, Jianhua
    Liu, Hantao
    RENEWABLE ENERGY, 2023, 206 : 1132 - 1146
  • [49] Influence of Intermittent Operation on Soil Temperature and Energy Storage Duration of Ground-Source Heat Pump System for Residential Building
    Yu, Tao
    Liu, Zhimei
    Chu, Guangming
    Qu, Yunxia
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 203 - 213
  • [50] Characteristics on energy saving and environmental protection in the direct urban sewage source heat pump system
    Qian Jianfeng
    Zhang Jili
    Sun Dexing
    6TH INTERNATIONAL SYMPOSIUM OF ASIA INSTITUTE OF URBAN ENVIRONMENT: ENERGY CONSERVATION AND CARBON OFF IN ASIA CITY, 2009, : 285 - 290