Automated counting of phytoplankton by pattern recognition: a comparison with a manual counting method

被引:72
|
作者
Embleton, KV [1 ]
Gibson, CE [1 ]
Heaney, SI [1 ]
机构
[1] Queens Univ Belfast, Aquat Syst Grp, Belfast BT9 5PX, Antrim, North Ireland
关键词
D O I
10.1093/plankt/25.6.669
中图分类号
Q17 [水生生物学];
学科分类号
071004 ;
摘要
Computer-based image analysis and pattern recognition methods were used to construct a system able automatically to identify, count and measure selected groups of phytoplankton. An image analysis algorithm was employed to isolate and measure objects from digitized images of a phytoplankton sample. The measurements obtained were used to identify selected groups of phytoplankton by a combination of artificial neural networks and simple rule-based procedures. The system was trained and tested using samples of lake water covering an annual growth cycle from Lough Neagh in Northern Ireland. Total volume estimates were obtained for the four major phytoplankton species, using both the automated system and a manual counting method. Estimates of total cell volume obtained from the automated system were within 10% of those derived by manual analysis of the same cells. The automated system produced total cell volume estimates close to those obtained from manual analysis of different aliquots of the same water sample. Variation between successive counts of the same water sample was higher with the automated system than with the manual counting method. Limitations and possible improvements to the technology are discussed.
引用
收藏
页码:669 / 681
页数:13
相关论文
共 50 条
  • [41] MEASUREMENT OF PHYTOPLANKTON GROWTH BY PARTICLE COUNTING
    SHELDON, RW
    LIMNOLOGY AND OCEANOGRAPHY, 1979, 24 (04) : 760 - 767
  • [42] The stability of phytoplankton counting with inverted microscope
    Chen M.
    Shi K.
    Li Z.
    Cai F.
    Zhang H.
    Zhang J.
    Hu W.
    Chen, Minghua (chenminghua@ncu.edu.cn), 1600, Science Press (32): : 1564 - 1574
  • [43] Microfluidic biochip for phytoplankton cell counting
    Machado, Leandro Matiolli
    Mattiello, Izadora
    Lopes, Rubens Mendes
    Carreno, M. N. P.
    2013 28TH SYMPOSIUM ON MICROELECTRONICS TECHNOLOGY AND DEVICES (SBMICRO 2013), 2013,
  • [44] An accurate automated speaker counting architecture based on James Webb Pattern
    Barua, Prabal Datta
    Yildiz, Arif Metehan
    Canpolat, Nida
    Keles, Tugce
    Dogan, Sengul
    Baygin, Mehmet
    Tuncer, Ilknur
    Tuncer, Turker
    Tan, Ru-San
    Fujita, Hamido
    Acharya, U. Rajendra
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 119
  • [45] A METHOD FOR PREPARING PERMANENT MOUNTS OF PHYTOPLANKTON FOR CRITICAL MICROSCOPY AND CELL COUNTING
    CRUMPTON, WG
    WETZEL, RG
    LIMNOLOGY AND OCEANOGRAPHY, 1981, 26 (05) : 976 - 980
  • [46] Comparison of manual and digital microvascular density counting of RECK expression in glioma
    Rahmah, Nunung Nur
    Sakai, Keiichi
    Li, Yuhui
    Sano, Kenji
    Hongo, Kazuhiro
    NEUROPATHOLOGY, 2012, 32 (03) : 245 - 251
  • [47] A Human Action Counting and Recognition Method Based on CSI
    Liu X.-W.
    Chen H.-M.
    Beijing Youdian Daxue Xuebao/Journal of Beijing University of Posts and Telecommunications, 2020, 43 (05): : 105 - 111
  • [48] Accuracy and precision comparison of the hemocytometer and automated cell counting methods
    Stone, Laurel Rebecca
    Gray, Diane R.
    Remple, Krissy
    Beaudet, Matthew P.
    FASEB JOURNAL, 2009, 23
  • [49] Framework Comparison of Neural Networks for Automated Counting of Vehicles and Pedestrians
    Lalangui, Galo
    Cordero, Jorge
    Ruiz-Vivanco, Omar
    Barba-Guaman, Luis
    Guerrero, Jessica
    Farias, Fatima
    Rivas, Wilmer
    Loja, Nancy
    Heredia, Andres
    Barros-Gavilanes, Gabriel
    APPLICATIONS OF COMPUTATIONAL INTELLIGENCE, COLCACI 2019, 2019, 1096 : 16 - 28
  • [50] Evaluation of the monocyte counting by the ABX Vega. Comparison with the manual method and fluoro-flow cytometry
    Morillon, M
    Maslin, J
    De Pina, JJ
    Louis, FJ
    Martet, G
    HEMATOLOGY AND CELL THERAPY, 1999, 41 (02) : 47 - 50