Parameter back-analysis of hardening soil model for granite residual soil and its engineering applications

被引:0
|
作者
Zhu Min [1 ,2 ]
Chen Xiang-sheng [1 ,2 ]
Zhang Guo-tao [1 ,2 ]
Pang Xiao-chao [3 ]
Su Dong [1 ,2 ]
Liu Ji-qiang [4 ]
机构
[1] Shenzhen Univ, Coll Civil & Transportat Engn, Shenzhen 518060, Guangdong, Peoples R China
[2] Shenzhen Univ, Minist Educ, Key Lab Coastal Urban Resilient Infrastruct, Shenzhen 518060, Guangdong, Peoples R China
[3] China Acad Railway Sci Shenzhen Res & Design Inst, Shenzhen 518060, Guangdong, Peoples R China
[4] China Railway Southern Investment Grp Co Ltd, Shenzhen 518060, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
granite residual soil; self-boring pressure meter test; hardening soil model; parameter back-analysis; foundation excavation; shield tunnel; SMALL-STRAIN STIFFNESS; NUMERICAL-ANALYSIS; HSS MODEL; EXCAVATION;
D O I
10.16285/j.rsm.2021.1062
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In recent years, construction works near the operating metro tunnel in granite residual soil have been gradually increasing, and the impact of these construction works on the safety of shield tunnel should not be ignored. Finite element method is an effective method to evaluate the influence of adjacent construction on shield tunnel, but its reliability highly depends on the reasonable selection of soil constitutive model and parameters. In this paper, the current situation of parameter selection of hardening soil model for granite residual soil is firstly reviewed. Then a back-analysis method for determining the parameters of granite residual soil based on the self-boring pressure meter test (SBPT) is proposed. Finally, the obtained back-analysis parameters are applied to the engineering case of foundation pit excavated overpass existing shield tunnel for method verification, and more reasonable values of parameters of hardening soil model for granite residual soil are determined. The results show that the strength parameters of hardening soil model for granite residual soil can be determined by laboratory tests, and the stiffness parameters of E-50(ref ), E-oed(ref) and E-ur(ref) are the key parameters for the back-analysis. The ratio of E-50(ref ): E-oed(ref) : E-ur(ref) is suitable for engineering practice, and the value of E-50(ref ) ranges from 36 MPa to 43 MPa according to different ratios.
引用
收藏
页码:1061 / 1072
页数:12
相关论文
共 36 条
  • [31] [尹松 Yin Song], 2017, [岩土工程学报, Chinese Journal of Geotechnical Engineering], V39, P743
  • [32] YU Gang, 2019, STRUCTURAL CHARACTER
  • [33] FINITE CAVITY EXPANSION IN DILATANT SOILS - LOADING ANALYSIS
    YU, HS
    HOULSBY, GT
    [J]. GEOTECHNIQUE, 1991, 41 (02): : 173 - 183
  • [34] Variability in unsaturated hydraulic properties of residual soil in Singapore
    Zhai, Qian
    Rahardjo, Harianto
    Satyanaga, Alfrendo
    [J]. ENGINEERING GEOLOGY, 2016, 209 : 21 - 29
  • [35] Zheng G, 2013, ROCK SOIL MECH, V34, P1459
  • [36] Remediation of Damaged Shield Tunnel Using Grouting Technique: Serviceability Improvements and Prevention of Potential Risks
    Zhu, Min
    Gong, Xiaonan
    Gao, Xiang
    Liu, Shiming
    Yan, Jiajia
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2019, 33 (06)