Non-contact sensing technology can allow quantitative measurement of sleep beyond the hospital setting, in a user-friendly and cost-effective manner. Wrist actigraphy has been extensively validated as an alternative to polysomnography (PSG), the gold standard in sleep monitoring. Results reported in the literature indicate actigraphy-based devices to be highly sensitive but poorly specific to sleep, without providing a breakdown of sleep into different stages [1, 2]. In this study, the sleep staging performance of a novel non-contact sensing technology was compared to PSG on healthy subjects. Forty subjects were recruited for this study, and a single night of their sleep was monitored using PSG and the non-contact sensor. Three experts scored the PSG data, and a consensus scoring was derived using a voting mechanism across the three scorers. Data were split into training and testing sets and proprietary algorithms were developed using the training set. The analysis presented in this paper refers only to the independent testing set. Inter-scorer variability of each scorer was assessed against the consensus scoring and compared to values quoted in the literature. PSG scoring for this study compared favorably to the scientific literature. The non-contact device algorithm produced good performance compared to PSG. No statistically significant difference in total time for each sleep stage, in sleep onset or sleep efficiency was observed. Furthermore, performance of the non-contact device in detecting Wake, REM and N3 sleep stage was superior to that reported in the literature for wrist actigraphy. The non-contact sensor technology presented can provide a viable alternative to PSG in the home environment, allowing reliable monitoring of longterm sleep trends.
引用
收藏
页码:77 / 80
页数:4
相关论文
共 50 条
  • [31] Non-contact NDE
    Palmer, SB
    INSIGHT, 1995, 37 (05) : 366 - 367
  • [32] Non-contact tester
    Murray, Jerry
    Printed Circuit Fabrication, 1999, 22 (02):
  • [33] NON-CONTACT TONOMETER
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 1977, 19 (22): : 91 - 92
  • [34] Non-contact thermometers
    不详
    GAS ENGINEERING & MANAGEMENT, 1997, 37 (07): : 38 - 38
  • [35] Non-contact thermometer
    不详
    CHIMICA OGGI-CHEMISTRY TODAY, 1997, 15 (6-7) : 83 - 83
  • [36] Non-Contact Contact Force Estimation for Pantograph and Catenary System Based on Kalman Filter
    Chen, Hongming
    Zhou, Ning
    Zhang, Weihua
    ADVANCES IN DYNAMICS OF VEHICLES ON ROADS AND TRACKS III, VOL 1, IAVSD 2023, 2025, : 41 - 50
  • [37] Non-contact measurement of contact wire
    Yi Yaxing
    Ye Xuemei
    Li Zhongke
    Yue Kaiduan
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [38] CONTACT AND NON-CONTACT SPECULAR MICROSCOPY
    PRICE, NC
    CHENG, H
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1981, 65 (08) : 568 - 574
  • [39] A study on the position estimation of the steel plate in non-contact conveyance system
    Kueon, Y
    Yoon, HJ
    Choi, JS
    Jung, KS
    Baek, YS
    Proceedings of the Second IASTED International Multi-Conference on Automation, Control, and Information Technology - Automation, Control, and Applications, 2005, : 433 - 438
  • [40] A Non-Contact Vision-Based System for Respiratory Rate Estimation
    Li, Michael H.
    Yadollahi, Azadeh
    Taati, Babak
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2119 - 2122