Contribution of power Doppler blood flow mapping to gray-scale ultrasound for predicting malignancy of adnexal masses in symptomatic and asymptomatic women

被引:11
|
作者
Luis Alcazar, Juan [1 ]
Guerriero, Stefano [2 ]
Laparte, Carmen [1 ]
Ajossa, Silvia [2 ]
Jurado, Matias [1 ]
机构
[1] Univ Navarra, Univ Navarra Clin, Dept Obstet & Gynecol, Pamplona 31008, Spain
[2] Univ Cagliari, Osped San Giovanni di Dio, Dept Obstet & Gynecol, Cagliari, Italy
关键词
Adnexal mass; Patients' symptoms; Ultrasound; Doppler; Sensitivity; Specificity; COLOR DOPPLER; OVARIAN-CANCER; CARCINOMA; DIAGNOSIS; ULTRASONOGRAPHY; SONOGRAPHY; ACCURACY; TRIAGE; TUMOR;
D O I
10.1016/j.ejogrb.2010.11.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine the contribution of power Doppler blood flow mapping to gray-scale ultrasound for predicting malignancy of adnexal masses in symptomatic and asymptomatic women. Study design: One thousand and ninety-four women with adnexal mass were included. Patients were divided into three groups according to clinical complaints: asymptomatic (group A), patients with symptoms non-suspicious of ovarian cancer (group B) and patients with symptoms suspicious of ovarian cancer (group C). All patients underwent transvaginal power Doppler ultrasound prior to surgery. Any mass in which the echo architecture at B-mode ultrasound was not highly suggestive of benign histology was categorized as questionable. In these cases power Doppler was performed as the second step. Definitive histological diagnosis was used as the standard reference. Sensitivity, specificity, positive likelihood ratio (+LR) and negative likelihood ratio (-LR) were calculated for B-mode diagnosis and B-mode plus Doppler in each group. Results: In group A, B-mode was significantly more sensitive (98.1%) than Doppler ultrasound (91.3%) (p < 0.01). In group B Doppler ultrasound (97.0%) was more specific than B-mode ultrasound (92.2%) (p < 0.001). In group C Doppler ultrasound (84.0%) was more specific than B-mode ultrasound (68.0%) (p < 0.001). Positive LR was significantly higher after Doppler evaluation in all groups (30.5 vs 12.8 in group A, 33.2 vs 12.8 in group B and 6.0 vs 3.1 in group C). Conclusions: The diagnostic performance of B-mode and power Doppler ultrasound is different depending on patients' complaints. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 49 条
  • [41] Power doppler ultrasound assessment of the relationship between age and ovarian perifollicular blood flow in women undergoing in vitro fertilization treatment
    Costello, Michael F.
    Shrestha, Sanu M.
    Sjoblom, Peter
    McNally, Glen
    Bennett, Michael J.
    Steigrad, Stephen J.
    Hughes, Graeme J.
    JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 2006, 23 (9-10) : 359 - 365
  • [42] Power doppler ultrasound assessment of the relationship between age and ovarian perifollicular blood flow in women undergoing in vitro fertilization treatment
    Michael F. Costello
    Sanu M. Shrestha
    Peter Sjoblom
    Glen McNally
    Michael J. Bennett
    Stephen J. Steigrad
    Graeme J. Hughes
    Journal of Assisted Reproduction and Genetics, 2006, 23 : 359 - 365
  • [43] Power Doppler ultrasound studies of ovarian, uterine, and endometrial blood flow in regularly menstruating women with respect to luteal phase defects
    Dal, J
    Vural, B
    Caliskan, E
    Ozkan, S
    Yucesoy, I
    FERTILITY AND STERILITY, 2005, 84 (01) : 224 - 227
  • [44] Power Doppler ultrasound assessment of ovarian perifollicular blood flow women with polycystic ovaries and normal ovaries during in vitro fertilaztion treatment
    Costello, MF
    Shrestha, SM
    Sjoblom, P
    McNally, G
    Bennett, MJ
    Steigrad, SJ
    Hughes, GJ
    FERTILITY AND STERILITY, 2005, 83 (04) : 945 - 954
  • [45] Value of Power Doppler and Gray-Scale US in the Diagnosis of Carpal Tunnel Syndrome: Contribution of Cross-Sectional Area just before the Tunnel Inlet as Compared with the Cross-Sectional Area at the Tunnel
    Akcar, Nevbahar
    Ozkan, Serhat
    Mehmetoglu, Ozlem
    Calisir, Cuneyt
    Adapinar, Baki
    KOREAN JOURNAL OF RADIOLOGY, 2010, 11 (06) : 632 - 639
  • [46] Multivariate feature analysis of sonographic findings of metastatic cervical lymph nodes: Contribution of blood flow features revealed by power Doppler sonography for predicting metastasis
    Chikui, T
    Yonetsu, K
    Nakamura, T
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (03) : 561 - 567
  • [47] RE: Value of Power Doppler and Gray-Scale US in the Diagnosis of Carpal Tunnel Syndrome: Contribution of Cross-Sectional Area just before the Tunnel Inlet as Compared with the Cross-Sectional Area at the Tunnel
    Sonmez, Guner
    Ozturk, Ersin
    KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (02) : 267 - 267
  • [48] Ablation of High Intensity Focused Ultrasound Combined with SonoVue on Rabbit VX2 Liver Tumors: Assessment with Conventional Gray-Scale US, Conventional Color/Power Doppler US, Contrast-Enhanced Color Doppler US, and Contrast-Enhanced Pulse-Inversion Harmonic US
    Wen Luo
    Xiaodong Zhou
    Guangbin He
    Qiuyang Li
    Xiaoying Zheng
    Zhiyong Fan
    Qing Liu
    Ming Yu
    Zenghui Han
    Jun Zhang
    Yunqiu Qian
    Annals of Surgical Oncology, 2008, 15
  • [49] Ablation of high intensity focused ultrasound combined with SonoVue on rabbit VX2 liver tumors: Assessment with conventional gray-scale US, conventional color/power Doppler US, contrast-enhanced color Doppler US, and contrast-enhanced pulse-inversion harmonic US
    Luo, Wen
    Zhou, Xiaodong
    He, Guangbin
    Li, Qiuyang
    Zheng, Xiaoying
    Fan, Zhiyong
    Liu, Qing
    Yu, Ming
    Han, Zenghui
    Zhang, Jun
    Qian, Yunqiu
    ANNALS OF SURGICAL ONCOLOGY, 2008, 15 (10) : 2943 - 2953