Electroanalytical detection of pindolol: comparison of unmodified and reduced graphene oxide modified screen-printed graphite electrodes

被引:37
|
作者
Cumba, Loanda R. [1 ,2 ]
Smith, Jamie P. [1 ]
Brownson, Dale A. C. [1 ]
Iniesta, Jesus [3 ,4 ]
Metters, Jonathan P. [1 ]
do Carmo, Devaney R. [2 ]
Banks, Craig E. [1 ]
机构
[1] Manchester Metropolitan Univ, Div Chem & Environm Sci, Sch Chem & Environm, Fac Sci & Engn, Manchester M1 5GD, Lancs, England
[2] Univ Estadual Paulista, UNESP, Fac Engn Ilha Solteira, Dept Quim & Fis, BR-15385000 Solteira, SP, Brazil
[3] Univ Alicante, Dept Phys Chem, Alicante 03690, Spain
[4] Univ Alicante, Inst Electrochem, Alicante 03690, Spain
关键词
ABSORPTION SPECTROMETRIC DETERMINATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; SPECTROPHOTOMETRIC DETERMINATION; FORENSIC ELECTROCHEMISTRY; URIC-ACID; SOLUBILITY; PROPRANOLOL; ENANTIOMERS; SENSORS; SERUM;
D O I
10.1039/c4an02005g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent work has reported the first electroanalytical detection of pindolol using reduced graphene oxide (RGO) modified glassy carbon electrodes [S. Smarzewska and W. Ciesielski, Anal. Methods, 2014, 6, 5038] where it was reported that the use of RGO provided significant improvements in the electroanalytical signal in comparison to a bare (unmodified) glassy carbon electrode. We demonstrate, for the first time, that the electroanalytical quantification of pindolol is actually possible using bare (unmodified) screen-printed graphite electrodes (SPEs). This paper addresses the electroanalytical determination of pindolol utilising RGO modified SPEs. Surprisingly, it is found that bare (unmodified) SPEs provide superior electrochemical signatures over that of RGO modified SPEs. Consequently the electroanalytical sensing of pindolol is explored at bare unmodified SPEs where a linear range between 0.1 mu M-10.0 mu M is found to be possible whilst offering a limit of detection (3 sigma) corresponding to 0.097 mu M. This provides a convenient yet analytically sensitive method for sensing pindolol. The optimised electroanalytical protocol using the unmodified SPEs, which requires no pre-treatment (electrode polishing) or electrode modification step (such as with the use of RGO), was then further applied to the determination of pindolol in urine samples. This work demonstrates that the use of RGO modified SPEs have no significant benefits when compared to the bare (unmodified) alternative and that the RGO free electrode surface can provide electro-analytically useful performances.
引用
收藏
页码:1543 / 1550
页数:8
相关论文
共 50 条
  • [21] Screen-printed electrodes based on hybrids of poly(ortho-ethoxyaniline) and reduced graphene oxide
    Carnauba, Jose H. S.
    de Araujo, Gabriela M.
    Cardoso, Milton A.
    Yee, Marcio
    Brett, Christopher M. A.
    Simoes, Fabio R.
    DIAMOND AND RELATED MATERIALS, 2024, 144
  • [22] NH2 linker for femtomolar label-free detection with reduced graphene oxide screen-printed electrodes
    Sethi, Jagriti
    Suhail, Ahmed
    Safarzadeh, Mina
    Sattar, Anas
    Wei, Yinghui
    Pan, Genhua
    CARBON, 2021, 179 : 514 - 522
  • [23] Amperometric Biosensors for Tyramine Determination Based on Graphene Oxide and Polyvinylferrocene Modified Screen-printed Electrodes
    Erden, Pinar Esra
    Erdogan, Zehra Ozden
    Ozturk, Funda
    Kocoglu, Irem Okman
    Kilic, Esma
    ELECTROANALYSIS, 2019, 31 (12) : 2368 - 2378
  • [24] An electrochemical platform for the selective detection of azathioprine utilizing a screen-printed carbon electrode modified with manganese oxide/reduced graphene oxide
    Selvi, Subash Vetri
    Nataraj, Nandini
    Chen, Shen-Ming
    Prasannan, Adhimoorthy
    NEW JOURNAL OF CHEMISTRY, 2021, 45 (07) : 3640 - 3651
  • [25] Determination of sunset yellow and tartrazine in drinks using screen-printed carbon electrodes modified with reduced graphene oxide and NiBTC frameworks
    Wu, Jen-Han
    Lee, Hui-Ling
    MICROCHEMICAL JOURNAL, 2020, 158
  • [26] Sensitive Portable Electrochemical Sensors for Antibiotic Chloramphenicol by Tin/Reduced Graphene Oxide-Modified Screen-Printed Carbon Electrodes
    Bunnasit, Sirisupa
    Thamsirianunt, Kidakarn
    Rakthabut, Ratchapon
    Jeamjumnunja, Kannika
    Prasittichai, Chaiya
    Siriwatcharapiboon, Wilai
    ACS APPLIED NANO MATERIALS, 2024, 7 (01) : 267 - 278
  • [27] Nanosilver and Graphene Oxide Modified Screen-Printed Carbon Electrode for Electrochemical Detection of Bisphenol A
    Wan, H.
    Xie, X.
    Liu, H.
    Mahmud, S.
    Liu, H.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (11) : 1640 - 1648
  • [28] Electrochemical Detection of Diclofenac Using a Screen-Printed Electrode Modified with Graphene Oxide and Phenanthroline
    Maghinici, Ana-Raluca
    Bounegru, Alexandra-Virginia
    Apetrei, Constantin
    CHEMOSENSORS, 2025, 13 (02)
  • [29] Reduced Graphene Oxide/Gold Nanoparticles Modified Screen-Printed Electrode for the Determination of Palmitic Acid
    Ching, Chin Boon
    Abdullah, Jaafar
    Yusof, Nor Azah
    JOURNAL OF SENSORS, 2021, 2021
  • [30] α-Cyclodextrin modified screen printed graphite electrodes for detection of phenols
    Kim, HJ
    Chang, SC
    Shim, YB
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2002, 23 (03) : 427 - 431