Characterizing a proton beam scanning system for Monte Carlo dose calculation in patients

被引:50
|
作者
Grassberger, C. [1 ,2 ]
Lomax, Anthony [2 ]
Paganetti, H. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 02期
关键词
active scanning proton therapy; Monte Carlo simulation; patient dose calculation; RANGE UNCERTAINTIES; THERAPY; TOPAS;
D O I
10.1088/0031-9155/60/2/633
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The presented work has two goals. First, to demonstrate the feasibility of accurately characterizing a proton radiation field at treatment head exit for Monte Carlo dose calculation of active scanning patient treatments. Second, to show that this characterization can be done based on measured depth dose curves and spot size alone, without consideration of the exact treatment head delivery system. This is demonstrated through calibration of a Monte Carlo code to the specific beam lines of two institutions, Massachusetts General Hospital (MGH) and Paul Scherrer Institute (PSI). Comparison of simulations modeling the full treatment head at MGH to ones employing a parameterized phase space of protons at treatment head exit reveals the adequacy of the method for patient simulations. The secondary particle production in the treatment head is typically below 0.2% of primary fluence, except for low-energy electrons (<0.6 MeV for 230 MeV protons), whose contribution to skin dose is negligible. However, there is significant difference between the two methods in the low-dose penumbra, making full treatment head simulations necessary to study out-of-field effects such as secondary cancer induction. To calibrate the Monte Carlo code to measurements in a water phantom, we use an analytical Bragg peak model to extract the range-dependent energy spread at the two institutions, as this quantity is usually not available through measurements. Comparison of the measured with the simulated depth dose curves demonstrates agreement within 0.5 mm over the entire energy range. Subsequently, we simulate three patient treatments with varying anatomical complexity (liver, head and neck and lung) to give an example how this approach can be employed to investigate site-specific discrepancies between treatment planning system and Monte Carlo simulations.
引用
收藏
页码:633 / 645
页数:13
相关论文
共 50 条
  • [31] Dosimetric Evaluation of a Commercial Proton Spot Scanning Monte Carlo (MC) Dose Calculation for Small Fields
    Regmi, R.
    Maes, D.
    Nevitt, Z.
    Leuro, E.
    Wong, T.
    Saini, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E262 - E262
  • [32] Experimental Validation and Calculation Benchmark for a Commercial Monte Carlo Pencil Beam Scanning Proton Therapy Treatment Planning System in Water
    Lin, L.
    Huang, S.
    Kang, M.
    Ainsley, C.
    Hiltunen, P.
    Vanderstraeten, R.
    Lindberg, J.
    Siljamaki, S.
    Wareing, T.
    Davis, I.
    Barnett, A.
    McGhee, J.
    Solberg, T.
    McDonough, J.
    Simone, C., II
    MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [33] A Monte Carlo Study on Fetal Dose from Craniospinal Irradiation with Proton Pencil Beam Scanning Treatment
    Yeom, Y.
    Griffin, K.
    Mille, M.
    Lee, C.
    O'Reilly, S.
    Dong, L.
    Jung, J.
    Lee, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [34] Dosimetric Accuracy of RayStation Monte Carlo for Dose Perturbation by Implanted Markers in Proton Pencil Beam Scanning
    Parham, M.
    Ahmad, S.
    Jin, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E450 - E450
  • [35] Searching for optimized selection of Monte Carlo dose calculation parameters for scanned beam proton therapy in RayStation
    Kim, Heejung
    Chung, Kwangzoo
    Han, Youngyih
    Park, Won
    Park, Hee Chul
    Lim, Do Hoon
    Choi, Doo Ho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 83 (07) : 572 - 580
  • [36] Searching for optimized selection of Monte Carlo dose calculation parameters for scanned beam proton therapy in RayStation
    Heejung Kim
    Kwangzoo Chung
    Youngyih Han
    Won Park
    Hee Chul Park
    Do Hoon Lim
    Doo Ho Choi
    Journal of the Korean Physical Society, 2023, 83 : 572 - 580
  • [37] Comparison of pencil beam algorithm and Monte Carlo dose calculation for proton therapy of paranasal sinus cancer
    Jiang, H
    Adams, J
    Rosenthal, S
    Kollipara, S
    Paganetti, H
    MEDICAL PHYSICS, 2005, 32 (06) : 2028 - 2028
  • [38] Monte Carlo vs. pencil-beam dose calculation for uncertainty estimation in proton therapy
    Wahl, N.
    Wieser, H.
    Burigo, L.
    Bangert, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S731 - S731
  • [39] Validation and Application of a Commercial Proton Monte Carlo Pencil Beam Scanning Treatment Planning System
    Huang, S.
    Maslowski, A.
    Hiltunen, P.
    Lin, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E589 - E589
  • [40] Monte Carlo dose calculation algorithm on a distributed system
    Chauvie, S
    Dominoni, M
    Marini, P
    Stasi, M
    Pia, MG
    Scielzo, G