COMPUTER SIMULATIONS FOR INTERNAL DOSIMETRY USING VOXEL MODELS

被引:3
|
作者
Kinase, Sakae [1 ]
Mohammadi, Akram [1 ]
Takahashi, Masa [1 ]
Saito, Kimiaki [1 ]
Zankl, Maria [2 ]
Kramer, Richard [3 ]
机构
[1] Japan Atom Energy Agcy, Tokai, Ibaraki 3191195, Japan
[2] Helmholtz Zentrum Munchen, D-85764 Neuherberg, Germany
[3] Univ Fed Pernambuco, BR-50740540 Recife, PE, Brazil
关键词
PHANTOMS; ADULT; MOUSE;
D O I
10.1093/rpd/ncr145
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the Japan Atomic Energy Agency, several studies have been conducted on the use of voxel models for internal dosimetry. Absorbed fractions (AFs) and S values have been evaluated for preclinical assessments of radiopharmaceuticals using human voxel models and a mouse voxel model. Computational calibration of in vivo measurement system has been also made using Japanese and Caucasian voxel models. In addition, for radiation protection of the environment, AFs have been evaluated using a frog voxel model. Each study was performed by using Monte Carlo simulations. Consequently, it was concluded that these data of Monte Carlo simulations and voxel models could adequately reproduce measurement results. Voxel models were found to be a significant tool for internal dosimetry since the models are anatomically realistic. This fact indicates that several studies on correction of the in vivo measurement efficiency for the variability of human subjects and interspecies scaling of organ doses will succeed.
引用
收藏
页码:191 / 194
页数:4
相关论文
共 50 条
  • [31] Japanese voxel-based computational models and their applications for electromagnetic dosimetry
    Electromagnetic Compatibility Group, Applied Electromagnetic Research Center, National Institute of Information and Communications Technology, 4-2-1, Nukuikitamachi, Koganei, Tokyo 184-8795, Japan
    URSI Gen. Assem. Sci. Symp., URSIGASS, 1600,
  • [32] IMIE computer codes: 10 y in the internal dosimetry
    Berkovski, V.
    Ratia, G.
    Bonchuk, Y.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 205 - 208
  • [33] COMPUTER SIMULATIONS AS PSYCHOLOGICAL MODELS
    STELZL, I
    PSYCHOLOGISCHE BEITRAGE, 1971, 13 (03): : 391 - 430
  • [34] Layers of Models in Computer Simulations
    Boyer-Kassem, Thomas
    INTERNATIONAL STUDIES IN THE PHILOSOPHY OF SCIENCE, 2014, 28 (04) : 417 - 436
  • [35] GENERAL-MODELS FOR USE IN INTERNAL DOSIMETRY
    JOHNSON, JR
    HEALTH PHYSICS, 1979, 37 (06): : 851 - 851
  • [36] Developing brain models of human aggression using computer simulations
    Reynolds, DV
    Masri, R
    Underwood, N
    AGGRESSIVE BEHAVIOR, 1999, 25 (01) : 57 - 58
  • [37] Mouse models for internal radiation dosimetry - Reply
    Muthuswamy, MS
    Roberson, PL
    Buchsbaum, DJ
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (11) : 1970 - 1970
  • [38] Models of ICRP for internal dosimetry - Status and perspectives
    Nosske, D
    RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 253 - 259
  • [39] Internal Dosimetry of Ellipsoidal Targets: Models and Applications
    Amato, E.
    Lizio, D.
    Campenni, A.
    Ruggeri, R. M.
    Herberg, A.
    Baldari, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S315 - S315
  • [40] Voxel-based mouse model for internal dose calculations using Monte Carlo simulations (MCNP)
    Bitar, A.
    Lisbona, A.
    Thedrez, P.
    Maurel, C. Sai
    Le Forestier, D.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S110 - S110