DeepFHR: intelligent prediction of fetal Acidemia using fetal heart rate signals based on convolutional neural network

被引:56
|
作者
Zhao, Zhidong [1 ,2 ]
Deng, Yanjun [1 ]
Zhang, Yang [3 ]
Zhang, Yefei [1 ]
Zhang, Xiaohong [1 ]
Shao, Lihuan [1 ]
机构
[1] Hangzhou Dianzi Univ, Coll Elect & Informat, Hangzhou, Peoples R China
[2] Hangzhou Dianzi Univ, Hangdian Smart City Res Ctr Zhejiang Prov, Hangzhou, Peoples R China
[3] Hangzhou Dianzi Univ, Sch Commun Engn, Hangzhou, Peoples R China
关键词
Fetal acidemia; Computer aided diagnosis system; Continuous wavelet transform; Convolutional neural network; Fetal heart rate; RECORDINGS; AGREEMENT; CLASSIFICATION; FEATURES; MODEL;
D O I
10.1186/s12911-019-1007-5
中图分类号
R-058 [];
学科分类号
摘要
Background: Fetal heart rate (FHR) monitoring is a screening tool used by obstetricians to evaluate the fetal state. Because of the complexity and non-linearity, a visual interpretation of FHR signals using common guidelines usually results in significant subjective inter-observer and intra-observer variability. Objective: Therefore, computer aided diagnosis (CAD) systems based on advanced artificial intelligence (AI) technology have recently been developed to assist obstetricians in making objective medical decisions. Methods: In this work, we present an 8-layer deep convolutional neural network (CNN) framework to automatically predict fetal acidemia. After signal preprocessing, the input 2-dimensional (2D) images are obtained using the continuous wavelet transform (CWT), which provides a better way to observe and capture the hidden characteristic information of the FHR signals in both the time and frequency domains. Unlike the conventional machine learning (ML) approaches, this work does not require the execution of complex feature engineering, i.e., feature extraction and selection. In fact, 2D CNN model can self-learn useful features from the input data with the prerequisite of not losing informative features, representing the tremendous advantage of deep learning (DL) over ML. Results: Based on the test open-access database (CTU-UHB), after comprehensive experimentation, we achieved better classification performance using the optimal CNN configuration compared to other state-of-the-art methods: the averaged ten-fold cross-validation of the accuracy, sensitivity, specificity, quality index defined as the geometric mean of the sensitivity and specificity, and the area under the curve yielded results of 98.34, 98.22, 94.87, 96.53 and 97.82%, respectively Conclusions: Once the proposed CNN model is successfully trained, the corresponding CAD system can be served as an effective tool to predict fetal asphyxia objectively and accurately.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Detection of fetal heart rate in ultrosonic echo signals
    Nie, KB
    Fan, SZ
    Liu, J
    Hou, CX
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 137 - 138
  • [42] Multiparametric Investigation of Dynamics in Fetal Heart Rate Signals
    Ponsiglione, Alfonso Maria
    Amato, Francesco
    Romano, Maria
    BIOENGINEERING-BASEL, 2022, 9 (01):
  • [43] Automatic fetal biometry prediction using a novel deep convolutional network architecture
    Oghli, Mostafa Ghelich
    Shabanzadeh, Ali
    Moradi, Shakiba
    Sirjani, Nasim
    Gerami, Reza
    Ghaderi, Payam
    Taheri, Morteza Sanei
    Shiri, Isaac
    Arabi, Hossein
    Zaidi, Habib
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 127 - 137
  • [44] A Comprehensive Feature Analysis of the Fetal Heart Rate Signal for the Intelligent Assessment of Fetal State
    Zhao, Zhidong
    Zhang, Yang
    Deng, Yanjun
    JOURNAL OF CLINICAL MEDICINE, 2018, 7 (08):
  • [45] Fetal state assessment using fuzzy analysis of fetal heart rate signals-Agreement with the neonatal outcome
    Czabanski, Robert
    Jezewski, Janusz
    Horoba, Krzysztof
    Jezewski, Michal
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2013, 33 (03) : 145 - 155
  • [46] Rapid detection of fetal compromise using input length invariant deep learning on fetal heart rate signals
    Mendis, Lochana
    Palaniswami, Marimuthu
    Keenan, Emerson
    Brownfoot, Fiona
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [47] A Prospective Cohort Study of Fetal Heart Rate Monitoring: Deceleration Area Is Predictive of Fetal Acidemia EDITORIAL COMMENT
    Cahill, Alison G.
    Tuuli, Methodius G.
    Stout, Molly J.
    Lopez, Julia D.
    Macones, George A.
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2018, 73 (10) : 560 - 562
  • [48] ACIDEMIA STIMULATES ACTH, VASOPRESSIN, AND HEART-RATE RESPONSES IN FETAL SHEEP
    WOOD, CE
    CHEN, HG
    AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (02): : R344 - R349
  • [49] The limits of electronic fetal heart rate monitoring in the prevention of neonatal metabolic acidemia
    Clark, Steven L.
    Hamilton, Emily F.
    Garite, Thomas J.
    Timmins, Audra
    Warrick, Philip A.
    Smith, Samuel
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (02) : 163.e1 - 163.e6
  • [50] Fetal heart rate nadir during bradycardia and umbilical artery acidemia at birth
    Lepercq, Jacques
    Nghiem, My-Anh
    Goffinet, Francois
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2021, 100 (05) : 964 - 970