A Study on the Optimization of Control Strategy of a Thermal Energy Storage System for Building Air-Conditioning

被引:3
|
作者
Khushairi, M. M. [1 ]
Abdullah, H. [2 ]
Hazran, H. [3 ]
机构
[1] Univ Teknol MARA, Facil Management Dept, Kampus Puncak Alam, Selangor, Malaysia
[2] Univ Tech Malaysia, Fac Mech Engn, Skudai, Malaysia
[3] Univ Teknol MARA, Fac Mech Engn, Shah Alam, Malaysia
关键词
Attributions: Thermal energy storage; control; chiller;
D O I
10.1016/j.proeng.2011.11.146
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many new buildings in Malaysia are installed with a centralized air-conditioning system integrated with thermal energy storage system. Building owners are motivated to reduce the operational costs and are being encouraged by the attractive tariff offered by the utility power provider. However, without proper control the operational costs can be even more than the conventional system due to the higher maximum demand charge. This paper describes the results of an investigation on the actual operating data of a centralized air-conditioning plant integrated with thermal energy storage system operated under two different control strategies. Comparisons on the electrical power consumption, overall plant efficiency and chiller coefficient of performance were carried out by using two identical building load profiles. The results show that the supply pressure control is better than delta-temperature control. The electrical power consumption, overall plant efficiency and chiller coefficient of performance for supply pressure control are 30.1%, 33.4% and 33.5% better than the delta-temperature control, respectively. Also from the general observation on the data it was found out that the storage tank is under utilised. The charging capacity is usually less than the nominal storage capacity. In order to further increase the performance characteristic the plant operation schedule need to be revised. (C) 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of Universiti Teknologi Mara Perak and Instituition of Surveyors Malaysia (ISM).
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Fundamental Study of a Thermal Storage Unit Using Light Weight Soil for a Green Roof Building Air-Conditioning System
    Otaka, Toshio
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 369 - 372
  • [32] A real-time experimental investigation of building integrated thermal energy storage with air-conditioning system for indoor temperature regulation
    Chinnasamy, Veerakumar
    Appukuttan, Sreekumar
    ENERGY STORAGE, 2019, 1 (03)
  • [33] OPTIMIZATION OF ENERGY COMSUPTION IN AN INTELLIGENT CONTROL SYSTEM OF HEATING AND AIR-CONDITIONING LABORATORY MODEL
    Nowak, Mariusz
    Urbaniak, Andrzej
    RYNEK ENERGII, 2010, (03): : 137 - 142
  • [34] Application of improved particle swarm optimization in the energy saving strategy for a central air-conditioning system
    Li, Jianwei
    Wang, Mengying
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (15) : 3512 - 3523
  • [35] THE USE OF A THERMAL IMAGING-SYSTEM IN BUILDING AND AIR-CONDITIONING APPLICATIONS
    WARD, IC
    INSIGHT, 1994, 36 (07) : 511 - 513
  • [36] Effects of external weather on the water consumption of Thermal-Energy-Storage Air-Conditioning system
    Sanzana, Mirza Rayana
    Abdulrazic, Mostafa Osama Mostafa
    Wong, Jing Ying
    Maul, Tomas
    Yip, Chun-Chieh
    ENERGY NEXUS, 2023, 10
  • [37] Exergonomic optimization of an air-conditioning system
    Cammarata, G
    Fichera, A
    Mammino, L
    Marletta, L
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1997, 119 (01): : 62 - 69
  • [38] Optimization of the operation of an air-conditioning system by means of a distributed control system
    Batista, Ana Paula
    de Almeida Freitas, Maria Eugenia
    Martins, Euler Cunha
    Jota, Fabio Goncalves
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 457 - +
  • [39] Application of thermal battery in the ice storage air-conditioning system as a subcooler
    Huang, Ming-Chao
    Chen, Bo-Ren
    Hsiao, Ming-Jer
    Chen, Sih-Li
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (02): : 245 - 253
  • [40] THERMAL STORAGE HVAC SYSTEM RETROFIT PROVIDES ECONOMICAL AIR-CONDITIONING
    SMITH, SF
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1993, 35 (03): : 28 - 30