Fab fragments imprinted SPR biosensor for real-time human immunoglobulin G detection

被引:87
|
作者
Erturk, Gizem [2 ]
Uzun, Lokman [1 ]
Tumer, M. Askin [2 ]
Say, Ridvan [3 ]
Denizli, Adil
机构
[1] Hacettepe Univ, Dept Chem, Fac Sci, Div Biochem, TR-06532 Ankara, Turkey
[2] Hacettepe Univ, Dept Biol, TR-06532 Ankara, Turkey
[3] Anadolu Univ, Dept Chem, Eskisehir, Turkey
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 28卷 / 01期
关键词
F-ab fragment; F-c fragment; Molecular imprinted polymers; Surface plasmon resonance sensors; Immunoglobulin G detection; ADSORPTION; AUTOANTIBODIES; PURIFICATION; SEPARATION; POLYMERS; MONOLITH; ANTIBODY; REMOVAL; SENSORS; PLASMA;
D O I
10.1016/j.bios.2011.07.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
F-ab fragments imprinted surface plasmon resonance (SPR) chip was prepared for the real-time detection of human immunoglobulin G (IgG). In order to attach polymerization precursor on SPR chip, the SPR chip surface was modified with allyl mercaptan. F-ab fragments of the IgG molecules were prepared by papain digestion procedure and collected by fast protein liquid chromatography (FPLC) system using Hi-Trap_r Protein A FF column. The collected Fab fragments were complexed with histidine containing specific monomer, N-methacryloyl-L-histidine methyl ester (MAH). Molecular imprinted polymeric nanofilm was prepared on SPR chip in the presence of ethylene glycol dimethacrylate and 2-hydroxyethylmethacrylate. The template molecules, F-ab fragments, were removed from the polymeric nanofilm using 1 M NaCl solution (pH: 7.4, phosphate buffer system). The molecular imprinted SPR chip was characterized by contact angle, atomic force microscopy and Fourier transform infrared spectroscopy. By the real-time IgG detection studies carried out using aqueous IgG solutions in different concentrations, the kinetics and isotherm parameters of the molecular imprinted SPR chip-IgG system were calculated. To show selectivity and specificity of the molecular imprinted SPR chip, competitive kinetic analyses were performed using bovine serum albumin (BSA), IgG, F-ab and F-c fragments in singular and competitive manner. As last step. IgG detection studies from human plasma were performed and the measured IgG concentrations were well matched with the results determined by enzyme-linked immunosorbent assay (ELISA). The results obtained with the molecular imprinted SPR chip were well fitted to Langmuir isotherm and the detection limit was found as 56 ng/mL. In the light of the results, we can conclude that the proposed molecular imprinted SPR chip can detect IgG molecules from both aqueous solutions and complex natural samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [41] A Real-Time Human Detection System for Video
    Zeng, Bobo
    Wang, Guijin
    Lin, Xinggang
    Liu, Chunxiao
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2012, E95D (07): : 1979 - 1988
  • [42] Real-time Detection of Human Body in Videos
    Smirg, Ondrej
    Smekal, Zdenek
    2012 35TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2012, : 784 - 788
  • [43] Real-time human motion detection and classification
    Khan, FS
    Baset, SA
    ISCON 2002: IEEE STUDENTS CONFERENCE ON EMERGING TECHNOLOGIES, PROCEEDINGS, 2002, : 135 - 138
  • [44] Real-time Detection of α-Thrombin Binding to Single-Strand DNA Aptamers by a Highly Sensitive Si-Based Waveguide SPR Biosensor
    Huang, Chi-Chieh
    Hsu, Hsin-Feng
    Chen, Sz-Hau
    Tsai, Kun-Yu
    Huang, Yang-Tung
    Lin, Chih-Sheng
    Hsu, Shih-Hsin
    THIRD ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2012, 8351
  • [45] REAL-TIME BIOSPECIFIC INTERACTION ANALYSIS OF A NATURAL HUMAN POLYREACTIVE MONOCLONAL IGM ANTIBODY AND ITS FAB AND SCFV FRAGMENTS WITH SEVERAL ANTIGENS
    ROGGENBUCK, D
    KONIG, H
    NIEMANN, B
    SCHOENHERR, G
    JAHN, S
    PORSTMANN, T
    SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1994, 40 (01) : 64 - 70
  • [46] An antibody-free bio-layer interferometry biosensor for immunoglobulin G1 detection in human serum by using molecularly imprinted polynorepinephrine
    Ventisette, S.
    Ferruzzi, T.
    Sestaioni, D.
    Palladino, P.
    Minunni, M.
    Scarano, S.
    BIOSENSORS & BIOELECTRONICS, 2025, 271
  • [47] Real-Time Ultralow Bacterial Detection With A Gap-Method Microcantilever Biosensor
    Fathy, Jino
    Jia, Zongchao
    Lai, Yongjun
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 1313 - 1321
  • [48] Love wave biosensor for real-time detection of okadaic acid as DSP phycotoxin
    Fournel, F.
    Baco, E.
    Mamani-Matsuda, M.
    Degueil, M.
    Bennetau, B.
    Moynet, D.
    Mossalayi, D.
    Vellutini, L.
    Pillot, J. -P.
    Dejous, C.
    Rebiere, D.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 831 - 834
  • [49] Real-time detection of plasma ferritin by electrochemical biosensor developed for biomedical analysis
    Gautam, Neha
    Chattopadhyay, Sudip
    Kar, Shantimoy
    Sarkar, Arnab
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 235
  • [50] Real-Time Biomolecular Binding Detection Using a Sensitive Photonic Crystal Biosensor
    Guo, Yunbo
    Ye, Jing Yong
    Divin, Charles
    Huang, Baohua
    Thomas, Thommey P.
    Baker, James R., Jr.
    Norris, Theodore B.
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5211 - 5218