Fab fragments imprinted SPR biosensor for real-time human immunoglobulin G detection

被引:87
|
作者
Erturk, Gizem [2 ]
Uzun, Lokman [1 ]
Tumer, M. Askin [2 ]
Say, Ridvan [3 ]
Denizli, Adil
机构
[1] Hacettepe Univ, Dept Chem, Fac Sci, Div Biochem, TR-06532 Ankara, Turkey
[2] Hacettepe Univ, Dept Biol, TR-06532 Ankara, Turkey
[3] Anadolu Univ, Dept Chem, Eskisehir, Turkey
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 28卷 / 01期
关键词
F-ab fragment; F-c fragment; Molecular imprinted polymers; Surface plasmon resonance sensors; Immunoglobulin G detection; ADSORPTION; AUTOANTIBODIES; PURIFICATION; SEPARATION; POLYMERS; MONOLITH; ANTIBODY; REMOVAL; SENSORS; PLASMA;
D O I
10.1016/j.bios.2011.07.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
F-ab fragments imprinted surface plasmon resonance (SPR) chip was prepared for the real-time detection of human immunoglobulin G (IgG). In order to attach polymerization precursor on SPR chip, the SPR chip surface was modified with allyl mercaptan. F-ab fragments of the IgG molecules were prepared by papain digestion procedure and collected by fast protein liquid chromatography (FPLC) system using Hi-Trap_r Protein A FF column. The collected Fab fragments were complexed with histidine containing specific monomer, N-methacryloyl-L-histidine methyl ester (MAH). Molecular imprinted polymeric nanofilm was prepared on SPR chip in the presence of ethylene glycol dimethacrylate and 2-hydroxyethylmethacrylate. The template molecules, F-ab fragments, were removed from the polymeric nanofilm using 1 M NaCl solution (pH: 7.4, phosphate buffer system). The molecular imprinted SPR chip was characterized by contact angle, atomic force microscopy and Fourier transform infrared spectroscopy. By the real-time IgG detection studies carried out using aqueous IgG solutions in different concentrations, the kinetics and isotherm parameters of the molecular imprinted SPR chip-IgG system were calculated. To show selectivity and specificity of the molecular imprinted SPR chip, competitive kinetic analyses were performed using bovine serum albumin (BSA), IgG, F-ab and F-c fragments in singular and competitive manner. As last step. IgG detection studies from human plasma were performed and the measured IgG concentrations were well matched with the results determined by enzyme-linked immunosorbent assay (ELISA). The results obtained with the molecular imprinted SPR chip were well fitted to Langmuir isotherm and the detection limit was found as 56 ng/mL. In the light of the results, we can conclude that the proposed molecular imprinted SPR chip can detect IgG molecules from both aqueous solutions and complex natural samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [1] A surface protein−imprinted biosensor based on boronate affinity for the detection of anti−human immunoglobulin G
    Zixuan Liu
    Zheng-Zhi Yin
    Wenrong Cai
    Datong Wu
    Junyao Li
    Yong Kong
    Microchimica Acta, 2022, 189
  • [2] Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor
    Sener, Gulsu
    Ozgur, Erdogan
    Rad, Abbas Yousefi
    Uzun, Lokman
    Say, Ridvan
    Denizli, Adil
    ANALYST, 2013, 138 (21) : 6422 - 6428
  • [3] A surface protein-imprinted biosensor based on boronate affinity for the detection of anti-human immunoglobulin G
    Liu, Zixuan
    Yin, Zheng-Zhi
    Cai, Wenrong
    Wu, Datong
    Li, Junyao
    Kong, Yong
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [4] Preparation and separation of Fab and Fc fragments from human immunoglobulin G with papain digestion
    Tang, Siyuan
    Lin, Dongqiang
    Tong, Hongfei
    Yao, Shanjing
    Huagong Xuebao/CIESC Journal, 2013, 64 (05): : 1750 - 1756
  • [5] Real-Time Detection of Protein Kinase A Activity by A Si-Based ARROW-B SPR Biosensor
    Hsu, Hsin-Feng
    Lin, Zheng-Wen
    Huang, Yang-Tung
    Yuan, Chiun-Jye
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2013,
  • [6] BINDING TO PROTEIN A OF IMMUNOGLOBULIN-G AND OF FAB AND FC FRAGMENTS
    ENDRESEN, C
    ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA SECTION C-IMMUNOLOGY, 1979, 87 (03): : 185 - 189
  • [7] An enzymatic electrochemical biosensor for real-time nicotine detection
    Kuzmanovic, Uros
    Chen, Mingfu
    Tararina, Margarita
    Shu, Nicholas
    Balijepalli, Anant
    Zamani, Marjon
    Fan, Andy
    Klapperich, Catherine
    Allen, Karen
    Grinstaff, Mark
    Galagan, James
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [8] Development of a microelectrochemical biosensor for the real-time detection of choline
    Baker, Keeley L.
    Bolger, Fiachra B.
    Lowry, John P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 412 - 420
  • [9] Performance enhancement of real-time detection of protozoan parasite, Cryptosporidium oocyst by a modified surface plasmon resonance (SPR) biosensor
    Kang, Chang Duk
    Lee, Sang Wook
    Park, Tai Hyun
    Sim, Sang Jun
    ENZYME AND MICROBIAL TECHNOLOGY, 2006, 39 (03) : 387 - 390
  • [10] BINDING OF RABBIT IMMUNOGLOBULIN-G FAB FRAGMENTS TO SUBTILISIN CARLSBERG
    STAUFFER, CE