Development and evaluation of isothermal amplification assay for the rapid and sensitive detection of Clostridium perfringens from chevon

被引:21
|
作者
Priya, Govindarajan Bhuvana [1 ]
Agrawal, Ravi Kant [2 ]
Milton, Arockiasamy Arun Prince [3 ]
Mishra, Madhu [1 ]
Mendiratta, Sanjod Kumar [2 ]
Agarwal, Rajesh Kumar [1 ]
Luke, Ashish [2 ]
Singh, Bhoj Raj [4 ]
Kumar, Deepak [5 ]
机构
[1] ICAR Indian Vet Res Inst, Div Bacteriol & Mycol, Izatnagar, Uttar Pradesh, India
[2] ICAR Indian Vet Res Inst, Div Livestock Prod Technol, Bareilly, Uttar Pradesh, India
[3] ICAR Res Complex North Eastern Hill Reg, Div Anim Hlth, Umiam, Meghalaya, India
[4] ICAR Indian Vet Res Inst, Div Vet Publ Hlth, Bareilly, Uttar Pradesh, India
[5] ICAR Indian Vet Res Inst, Div Vet Biotechnol, Bareilly, Uttar Pradesh, India
关键词
Clostridium perfringens diagnostics cpa; Loop-mediated isothermal amplification; Chevon; LAMP; PREVALENCE; ACCURATE; GENE; LAMP;
D O I
10.1016/j.anaerobe.2018.09.005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Loop-mediated isothermal amplification (LAMP) is a promising, simple, rapid and sensitive molecular detection method. In the present study, LAMP assay was developed for detecting Clostridium perfringens in chevon. Primers were designed to detect the cpa gene of C. perfringens. A panel of 19 bacterial strains, including 3 C. perfringens and 16 other strains, were included in this study to standardize and evaluate the LAMP assay. No false positive amplification was observed indicating 100% specificity of the assay. The detection limit of LAMP and conventional PCR in the DNA extracted from pure C perfringens was 0.34 pg and 3.4 pg, respectively. This revealed that LAMP assay is 10 times more sensitive than conventional PCR. The sensitivity of the LAMP assay for the detection of C perfringens in raw chevon was found to be 1.2 x 10(2) CFU/g after 6-h enrichment and 1.2 x 10(5) CFU/g without enrichment in artificial spiking studies. Improved C perfringens detection of 12 CFU/g within 12 h was obtained proving that LAMP assay is significantly faster than traditional methods that take >2 d. The developed LAMP assay also detected the targeted organism in clinical and environmental samples with the sensitivity and specificity of 97% and 84%, respectively with Kappa agreement of 0.824 respects to PCR assay. This method shows immense potential for routine diagnosis and monitoring of C perfringens in food, environment and clinical samples. This is the first report in which the LAMP assay was optimized for the detection of C perfringens in chevon. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:178 / 187
页数:10
相关论文
共 50 条
  • [21] Development of a Loop-Mediated Isothermal Amplification Assay for Rapid, Sensitive and Specific Detection of a Campylobacter jejuni Clone
    Luo, Yan
    Sahin, Orhan
    Dai, Lei
    Sippy, Rachel
    Wu, Zuowei
    Zhang, Qijing
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2012, 74 (05): : 591 - 596
  • [22] Development of a loop-mediated isothermal amplification assay for rapid and sensitive detection of ostreid herpesvirus 1 DNA
    Ren, Weicheng
    Renault, Tristan
    Cai, Yuyong
    Wang, Chongming
    JOURNAL OF VIROLOGICAL METHODS, 2010, 170 (1-2) : 30 - 36
  • [23] Loop-mediated isothermal amplification assay for sensitive and rapid detection of Phytophthora capsici
    Dong, Zhongmei
    Liu, Peiqing
    Li, Benjin
    Chen, Guoliang
    Weng, Qiyong
    Chen, Qinghe
    CANADIAN JOURNAL OF PLANT PATHOLOGY, 2015, 37 (04) : 485 - 494
  • [24] Development of a loop-mediated isothermal amplification assay for rapid and sensitive detection of Hemileia vastatrix in coffee plantations
    Wu, Weihuai
    Wang, Guihua
    Wang, Han
    Gbokie, Thomas
    He, Chunping
    Huang, Xing
    Liang, Yanqiong
    Li, Rui
    Yi, Kexian
    TROPICAL PLANT PATHOLOGY, 2024, 49 (04) : 515 - 524
  • [25] Development of a rapid, specific and sensitive isothermal assay for the detection of Verticillium alfalfae
    Gaige, A. J. Reyes
    Dung, J. K. S.
    Weiland, J. E.
    PHYTOPATHOLOGY, 2017, 107 (12) : 53 - 53
  • [26] Sensitive and Rapid Detection of ermB Gene in Clostridium difficile by Loop-Mediated Isothermal Amplification
    Lin, Minyi
    Liu, Wei
    Wang, Pu
    Zhou, Youlian
    Tan, Jiasheng
    Wu, Peiqun
    Mo, ZhiHui
    Zhang, Ting
    Xie, Shan
    Wang, Zhongqiu
    Fei, Jiaxi
    Yuan, Jing
    Chen, Ye
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S113 - S113
  • [27] Development and evaluation of a loop-mediated isothermal amplification assay for the rapid detection of Staphylococcus aureus in food
    Yang, Hong
    Ma, Xiaoyan
    Zhang, Xianzhou
    Wang, Yu
    Zhang, Wei
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2011, 232 (05) : 769 - 776
  • [28] Development and evaluation of a loop-mediated isothermal amplification assay for rapid detection and identification of Pectobacterium atrosepticum
    Li, Xiang
    Nie, Jingbai
    Ward, Leonard J.
    Nickerson, Jennifer
    De Boer, Solke H.
    CANADIAN JOURNAL OF PLANT PATHOLOGY, 2011, 33 (04) : 447 - 457
  • [29] Development and evaluation of a loop-mediated isothermal amplification assay for the rapid detection of Staphylococcus aureus in food
    Hong Yang
    Xiaoyan Ma
    Xianzhou Zhang
    Yu Wang
    Wei Zhang
    European Food Research and Technology, 2011, 232 : 769 - 776
  • [30] Development and evaluation of a loop-mediated isothermal amplification assay for rapid detection of lymphocystis disease virus
    Li, Qiong
    Yue, Zhiqin
    Liu, Hong
    Liang, Chengzhu
    Zheng, Xiaolong
    Zhao, Yuran
    Chen, Xiao
    Xiao, Xizhi
    Chen, Changfu
    JOURNAL OF VIROLOGICAL METHODS, 2010, 163 (02) : 378 - 384