Preconcentration and voltammetry of mercury on a functionalized sol-gel thin film modified glassy carbon electrode

被引:29
|
作者
Guo, YZ [1 ]
Guadalupe, AR [1 ]
机构
[1] Univ Puerto Rico, Dept Chem, San Juan, PR 00931 USA
关键词
chemically modified electrodes; sensors; sol-gel films; mercury; electroanalysis;
D O I
10.1016/S0731-7085(98)00133-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A functionalized sol-gel thin film modified glassy carbon electrode has been prepared for the determination of mercury. The tetrasulfide in the sol-gel matrix has a high affinity for mercury species. The chemically integrated functional groups in the sol-gel precursor ensure a high chemical and mechanical stability of the modified electrodes, and therefore a stable and reproducible analytical performance. By medium exchange anodic stripping voltammetry, this modified electrode allows reliable, low cost and interference-free determination of mercury. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 50 条
  • [31] Direct voltammetry of catalase immobilized on silica sol-gel and cysteine modified gold electrode and its application
    Di, Junwei
    Zhang, Min
    Yao, Kaian
    Bi, Shuping
    BIOSENSORS & BIOELECTRONICS, 2006, 22 (02): : 247 - 252
  • [32] Oxidation of a phospholipid at an electrode modified with an electrochemically formed sol-gel film doped with cyclodextrin
    Wandstrat, Michelle M.
    Spendel, Wolfgang U.
    Pacey, Gilbert E.
    Cox, James A.
    ELECTROANALYSIS, 2007, 19 (2-3) : 139 - 143
  • [33] Determination of Nanomolar Mercury(II) Concentration by Anodic-Stripping Voltammetry at a Carbon Paste Electrode Modified with Functionalized Nanoporous Silica Gel
    Javanbakht, Mehran
    Khoshsafar, Hamid
    Ganjali, Mohammad R.
    Badiei, Alireza
    Norouzi, Parviz
    Hasheminasab, Abed
    CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (01) : 35 - 41
  • [34] Determination of Cr(VI) at a sol-gel modified electrode
    Carrington, Nathan A.
    Yong, Li
    Xue, Zi-Ling
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [35] Formation of a molecular glue based on the electrochemical reduction of 4-hydroxyphenyldiazonium for the attachment of thin sol-gel film on glassy carbon
    Shapiro, Leora
    Mandler, Daniel
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2007, 221 (9-10): : 1237 - 1243
  • [36] Mercury-free detection of europium (III) at a glassy carbon electrode modified with carbon nanotubes by adsorptive stripping voltammetry
    Yuan, SA
    He, QO
    Yao, SJ
    Hu, SS
    ANALYTICAL LETTERS, 2006, 39 (02) : 373 - 385
  • [37] Use of Mercury Film Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes in Electrochemical Analysis of DNA
    Serpi, Constantina
    Voulgaropoulos, Anastasios
    Girousi, Stella
    ELECTROANALYSIS, 2013, 25 (05) : 1256 - 1262
  • [38] Determination of Creatinine in Urine by Voltammetry and Glassy Carbon Electrode Modified with Functionalized Multi-walled Carbon Nanotubes and Copper
    Pedrozo-Penafiel, Marlin J.
    Lopes, Thais
    Gutierrez-Beleno, Luis M.
    Miranda-Andrades, Jarol R.
    Maia Da Costa, Marcelo E. H.
    Larrude, Dunieskys G.
    Aucelio, Ricardo Q.
    ELECTROANALYSIS, 2023, 35 (02)
  • [39] Selective electrochemical sensor for theophylline based on an electrode modified with imprinted sol-gel film immobilized on carbon nanoparticle layer
    Guney, Sevgi
    Cebeci, Fevzi C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 307 - 314
  • [40] An electrochemical biosensor with cholesterol oxidase/sol-gel film on a nanoplatinum/carbon nanotube electrode
    Shi, QC
    Peng, TZ
    Zhu, YN
    Yang, CF
    ELECTROANALYSIS, 2005, 17 (10) : 857 - 861