Tamoxifen Metabolite Isomer Separation and Quantification by Liquid Chromatography-Tandem Mass Spectrometry

被引:25
|
作者
Jaremko, Malgorzata [1 ]
Kasai, Yumi [1 ]
Barginear, Myra F. [2 ]
Raptis, George [2 ]
Desnick, Robert J. [1 ]
Yu, Chunli [1 ]
机构
[1] Mt Sinai Sch Med, Dept Genet & Genom Sci, New York, NY 10029 USA
[2] Mt Sinai Sch Med, Dept Hematol & Med Oncol, New York, NY 10029 USA
关键词
BREAST-CANCER; CYP2D6; GENOTYPE; PLASMA; PHARMACOKINETICS; PHARMACOGENOMICS; IDENTIFICATION; ASSOCIATION; WOMEN; SERUM;
D O I
10.1021/ac102337d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tamoxifen (Tam), the antiestrogen used to treat estrogen receptor-positive breast cancer is a pro-drug that is converted to its major active metabolites, endoxifen and 4-hydroxy-tamoxifen (4-OH-Tam) by various biotransformation enzymes of which cytochrome P450-2D6 (CYP2D6) is key. The usual Tam dose is 20 mg daily; however, the plasma active metabolite concentrations vary due to common genetic variants encoding the biotransformation enzymes and environmental factors (e.g., concomitant drugs) that inhibit these enzymes. Effective treatment depends on adequate Tam conversion to its active isomers. To monitor metabolite plasma levels, a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to separate and quantitate Tam, N-desmethyl-tamoxifen (ND-Tam), and tamoxifen-N-oxide (Tam-N-oxide), and the E, Z, and Z isomers of endoxifen and 4-OH-Tam. Known standards were used to identify each metabolite/isomer. Quantitation of these metabolites in plasma was linear from 0.6 to 2000 nM. Intra- and inter-assay reproducibilities were 0.2-8.4% and 0.6-6.3%, respectively. Accuracy determined by spike experiments with known standards was 86-103%. Endoxifen, 4-OH-Tam, and their isomers were stable in fresh frozen plasma for >= 6 months. This method provides the first sensitive, specific, accurate, and reproducible quantitation of Tam and its metabolite isomers for monitoring Tam-treated breast cancer patients.
引用
收藏
页码:10186 / 10193
页数:8
相关论文
共 50 条
  • [41] Quantification of nimetazepam and its metabolite in human hair samples using liquid chromatography-tandem mass spectrometry: Case report
    Dai, Yinyin
    Han, Lifeng
    Wang, Yue
    Zhao, Kundi
    Gu, Jie
    Bai, Huiru
    Zheng, Lei
    Guo, Shu
    Liu, Lijiao
    Hasegawa, Koutaro
    Wurita, Amin
    LEGAL MEDICINE, 2023, 65
  • [42] Determination of trenbolone and its metabolite in bovine fluids by liquid chromatography-tandem mass spectrometry
    Buiarelli, F
    Cartoni, GP
    Coccioli, F
    De Rossi, A
    Neri, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (01): : 1 - 15
  • [43] A sensitive liquid chromatography-tandem mass spectrometry method for the quantification of valacyclovir and its metabolite acyclovir in mouse and human plasma
    Shi, Jian
    Hu, Yongjun
    Smith, David E.
    Zhu, Hao-Jie
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 447 - 452
  • [44] Quantification of Usaramine and its N-Oxide Metabolite in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Lin, Feifei
    Ma, Yan
    Pan, Anni
    Ye, Yang
    Liu, Jia
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2021, 46 (05) : 512 - 518
  • [45] Effect of liquid chromatography separation of complex matrices on liquid chromatography-tandem mass spectrometry signal suppression
    Choi, BK
    Hercules, DM
    Gusev, AI
    JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) : 337 - 342
  • [46] SUBCELLULAR QUANTIFICATION OF DOXORUBICIN AND ITS METABOLITE IN CULTURED HUMAN LEUKEMIA CELLS USING LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Xu, Jinhui
    Liu, Yuan
    Yu, Ying
    Ni, Qingjiang
    Chen, Yun
    ANALYTICAL LETTERS, 2012, 45 (14) : 1980 - 1994
  • [47] A novel method for quantification of sulfolane (a metabolite of busulfan) in plasma by gas chromatography-tandem mass spectrometry
    Versace, Francois
    Uppugunduri, Chakradhara Rao S.
    Krajinovic, Maja
    Theoret, Yves
    Gumy-Pause, Fabienne
    Mangin, Patrice
    Staub, Christian
    Ansari, Marc
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (6-7) : 1831 - 1838
  • [48] Ganglioside isomer analysis using ion polarity switching liquid chromatography-tandem mass spectrometry
    Li, Zhucui
    Zhang, Qibin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (12) : 3269 - 3279
  • [49] Ganglioside isomer analysis using ion polarity switching liquid chromatography-tandem mass spectrometry
    Zhucui Li
    Qibin Zhang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 3269 - 3279
  • [50] Analysis of acrylamide in different foodstuffs using liquid chromatography-tandem mass spectrometry and gas chromatography-tandem mass spectrometry
    Hoenicke, K
    Gatermann, R
    Harder, W
    Hartig, L
    ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 207 - 215