High Capacity Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry: Coupling a Porous Sheathless Interface with Transient-Isotachophoresis

被引:145
|
作者
Busnel, Jean-Marc [1 ,2 ]
Schoenmaker, Bart [1 ]
Ramautar, Rawi [1 ]
Carrasco-Pancorbo, Alegria [1 ]
Ratnayake, Chitra [2 ]
Feitelson, Jerald S. [2 ]
Chapman, Jeff D. [2 ]
Deelder, Andre M. [1 ]
Mayboroda, Oleg A. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Parasitol, Biomol Mass Spectrometry Unit, Leiden, Netherlands
[2] Beckman Coulter Inc, Brea, CA 92822 USA
关键词
ZONE-ELECTROPHORESIS; FLOW; ESI; MS;
D O I
10.1021/ac102159d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sheathless interface making use of a porous tip has been used for coupling capillary electrophoresis and electrospray ionization mass spectrometry. First, effective flow rates using the interface have been characterized. It was found that the interface is capable of generating a stable spray with flow rates ranging from below 10 nL/min to >340 nL/min, enabling its use in either the mass or concentration-sensitive region of the electrospray process. Subsequently, by analyzing peptide mixtures of increasing complexity, we have demonstrated that this platform provides exquisite sensitivity enabling the detection of very low amounts of materials with very high resolving power. Transient isotachophoresis (t-ITP) can also be integrated with this setup to increase the mass loading of the system while maintaining peak efficiency and resolution. Concentration limits of detection in the subnanomolar or nanomolar range can be achieved with or without t-ITP, respectively. The application of a vacuum at the inlet of the separation capillary further allowed the peak capacity of the system to be improved while also enhancing its efficiency. As a final step in this study, it was demonstrated that the intrinsic properties of the interface allows the use of coated noncharged surfaces so that very high peak capacities can be achieved.
引用
收藏
页码:9476 / 9483
页数:8
相关论文
共 50 条
  • [21] Capillary electrophoresis mass spectrometry with sheathless electrospray ionization for high sensitivity analysis of underivatized amino acids
    Jeong, Ji-Seon
    Kim, Sook-Kyung
    Park, Sang-Ryoul
    ELECTROPHORESIS, 2012, 33 (14) : 2112 - 2121
  • [22] Development of a multiplexed interface for capillary electrophoresis-electrospray ion trap mass spectrometry
    Li, Fu-An
    Wu, Ming-Chi
    Her, Guor-Rong
    ANALYTICAL CHEMISTRY, 2006, 78 (15) : 5316 - 5321
  • [23] Microfabricated devices for capillary electrophoresis-electrospray mass spectrometry
    Zhang, B.
    Liu, H.
    Karger, B.L.
    Foret, F.
    Analytical Chemistry, 71 (15): : 3258 - 3264
  • [24] Microfabricated devices for capillary electrophoresis-electrospray mass spectrometry
    Zhang, B
    Liu, H
    Karger, BL
    Foret, F
    ANALYTICAL CHEMISTRY, 1999, 71 (15) : 3258 - 3264
  • [25] New sheathless interface for coupling capillary electrophoresis to electrospray mass spectrometry evaluated by the analysis of fatty acids and prostaglandins
    Petersson, MA
    Hulthe, G
    Fogelqvist, E
    JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) : 141 - 154
  • [26] Development and Application of Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry System Based on A Coaxial Sheath Flow Interface
    Zhu, Liu
    Zhang, Nai-Qian
    Fang, Pan
    Pan, Jian-Zhang
    Wong, Catherine
    Fang, Qun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (01) : 34 - 41
  • [27] Determination of yessotoxins and pectenotoxins in shellfish by capillary electrophoresis-electrospray ionization-mass spectrometry
    de la Iglesia, P.
    Gago-Martinez, A.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (02): : 221 - 228
  • [28] CAPILLARY ZONE ELECTROPHORESIS AND ISOTACHOPHORESIS MASS-SPECTROMETRY OF POLYPEPTIDES AND PROTEINS BASED UPON AN ELECTROSPRAY IONIZATION INTERFACE
    SMITH, RD
    LOO, JA
    BARINAGA, CJ
    EDMONDS, CG
    UDSETH, HR
    JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 211 - 232
  • [29] Ultrasensitive determination of organotin compounds in plastic food packaging and edible oils by sheathless capillary electrophoresis-electrospray ionization-mass spectrometry
    He, Huiyu
    Tian, Miaomiao
    Hu, Lihuan
    Yang, Li
    ANALYST, 2020, 145 (06) : 2286 - 2296
  • [30] Feasibility of nonvolatile buffers in capillary electrophoresis-electrospray ionization-mass spectrometry of proteins
    Eriksson, JHC
    Mol, R
    Somsen, GW
    Hinrichs, WLJ
    Frijlink, HW
    de Jong, GJ
    ELECTROPHORESIS, 2004, 25 (01) : 43 - 49