Magnetic resonance imaging in patients with pacemakers and implantable cardioverter-defibrillators: A systematic review

被引:4
|
作者
Martins, R. -P. [1 ,2 ,3 ,4 ]
Baruteau, A. -E. [1 ,2 ,3 ,4 ]
Treguer, F. [1 ,5 ]
Cesari, O. [1 ]
Carsin-Nicol, B. [6 ]
Langella, B. [6 ]
Leclercq, C. [1 ,2 ,3 ,4 ]
Daubert, J. -C. [1 ,2 ,3 ,4 ]
Mabo, P. [1 ,2 ,3 ,4 ]
机构
[1] CHU Rennes, Serv Cardiol & Malad Vasc, F-35033 Rennes, France
[2] Univ Rennes 1, LTSI, F-35000 Rennes, France
[3] INSERM, U642, F-35000 Rennes, France
[4] INSERM, CIC IT 804, F-35000 Rennes, France
[5] CHU Angers, Serv Cardiol, F-49000 Angers, France
[6] CHU Rennes, Dept Radiol & Imagerie Med, F-35000 Rennes, France
来源
关键词
Magnetic resonance imaging; Pacemaker; Implantable cardioverter defibrillator; Electromagnetic interference; Safety; CARDIAC-PACEMAKERS; IN-VITRO; PERMANENT PACEMAKERS; SAFE PERFORMANCE; 1.5; TESLA; DEPENDENT PATIENTS; MRI; ICDS; 1.5-TESLA; FIELDS;
D O I
10.1016/j.ancard.2009.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The presence of a pacemaker or an implantable cardioverter-defibrillator was historically considered a contraindication to magnetic resonance imaging (MRI), due to the risks for both patient and device: reed-switch closure responsible for asynchronous pacing, inhibition of pacing, rapid ventricular pacing, heating on the lead tip or even device displacement ... However, manies recent studies demonstrate that if MRI is crucial for the management of the patient, it can be performed under specific monitoring and scanning conditions and after device reprogramming. The growing implication of device constructors in constructing a MRI safety device will perhaps extend in the future the indications of this imaging modality in implanted patients. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 50 条
  • [1] Magnetic Resonance Imaging in Patients With Implantable Cardioverter-Defibrillators and Pacemakers
    Roguin, Ariel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (06) : 556 - 557
  • [2] Experiences of magnetic resonance imaging scanning in patients with pacemakers or implantable cardioverter-defibrillators
    Han, Donghoon
    Kang, Si-Hyuck
    Cho, Youngjin
    Oh, Il-Young
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2019, 34 (01): : 99 - +
  • [3] Quantitative Assessment of Artifacts on Cardiac Magnetic Resonance Imaging of Patients With Pacemakers and Implantable Cardioverter-Defibrillators
    Sasaki, Takeshi
    Hansford, Rozann
    Zviman, Menekhem M.
    Kolandaivelu, Aravindan
    Bluemke, David A.
    Berger, Ronald D.
    Calkins, Hugh
    Halperin, Henry R.
    Nazarian, Saman
    CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (06) : 662 - U104
  • [4] Magnetic resonance imaging in non-conditional pacemakers and implantable cardioverter-defibrillators: a systematic review and meta-analysis
    Munawar, Dian A.
    Chan, Joel E. Z.
    Emami, Mehrdad
    Kadhim, Kadhim
    Khokhar, Kashif
    O'Shea, Catherine
    Iwai, Shinsuke
    Pitman, Bradley
    Linz, Dominik
    Munawar, Muhammad
    Roberts-Thomson, Kurt
    Young, Glenn D.
    Mahajan, Rajiv
    Sanders, Prashanthan
    Lau, Dennis H.
    EUROPACE, 2020, 22 (02): : 288 - 298
  • [5] Magnetic resonance imaging, pacemakers and implantable cardioverter-defibrillators: current situation and clinical perspective
    Gotte, M. J. W.
    Russel, I. K.
    de Roest, G. J.
    Germans, T.
    Veldkamp, R. F.
    Knaapen, P.
    Allaart, C. P.
    van Rossum, A. C.
    NETHERLANDS HEART JOURNAL, 2010, 18 (01) : 31 - 37
  • [6] Recent innovations in the development of magnetic resonance imaging conditional pacemakers and implantable cardioverter-defibrillators
    Lobodzinski, S. Suave
    CARDIOLOGY JOURNAL, 2012, 19 (01) : 98 - 104
  • [7] Pacemakers and implantable cardioverter-defibrillators in pediatric patients
    Silka, Michael J.
    Bar-Cohen, Yaniv
    HEART RHYTHM, 2006, 3 (11) : 1360 - 1366
  • [8] Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions
    Mollerus, Michael
    Albin, Glenn
    Lipinski, Margaret
    Lucca, Jill
    EUROPACE, 2010, 12 (07): : 947 - 951
  • [9] Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restriction
    Mollerus, M.
    Albin, G.
    Lipinski, M.
    Lucca, J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 130 - 130
  • [10] Troubleshooting pacemakers and implantable cardioverter-defibrillators
    Scher, DL
    CURRENT OPINION IN CARDIOLOGY, 2004, 19 (01) : 36 - 46