Magnetic resonance imaging in patients with pacemakers and implantable cardioverter-defibrillators: A systematic review

被引:4
|
作者
Martins, R. -P. [1 ,2 ,3 ,4 ]
Baruteau, A. -E. [1 ,2 ,3 ,4 ]
Treguer, F. [1 ,5 ]
Cesari, O. [1 ]
Carsin-Nicol, B. [6 ]
Langella, B. [6 ]
Leclercq, C. [1 ,2 ,3 ,4 ]
Daubert, J. -C. [1 ,2 ,3 ,4 ]
Mabo, P. [1 ,2 ,3 ,4 ]
机构
[1] CHU Rennes, Serv Cardiol & Malad Vasc, F-35033 Rennes, France
[2] Univ Rennes 1, LTSI, F-35000 Rennes, France
[3] INSERM, U642, F-35000 Rennes, France
[4] INSERM, CIC IT 804, F-35000 Rennes, France
[5] CHU Angers, Serv Cardiol, F-49000 Angers, France
[6] CHU Rennes, Dept Radiol & Imagerie Med, F-35000 Rennes, France
来源
关键词
Magnetic resonance imaging; Pacemaker; Implantable cardioverter defibrillator; Electromagnetic interference; Safety; CARDIAC-PACEMAKERS; IN-VITRO; PERMANENT PACEMAKERS; SAFE PERFORMANCE; 1.5; TESLA; DEPENDENT PATIENTS; MRI; ICDS; 1.5-TESLA; FIELDS;
D O I
10.1016/j.ancard.2009.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The presence of a pacemaker or an implantable cardioverter-defibrillator was historically considered a contraindication to magnetic resonance imaging (MRI), due to the risks for both patient and device: reed-switch closure responsible for asynchronous pacing, inhibition of pacing, rapid ventricular pacing, heating on the lead tip or even device displacement ... However, manies recent studies demonstrate that if MRI is crucial for the management of the patient, it can be performed under specific monitoring and scanning conditions and after device reprogramming. The growing implication of device constructors in constructing a MRI safety device will perhaps extend in the future the indications of this imaging modality in implanted patients. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 50 条
  • [31] Leadless Cardiac Devices—Pacemakers and Implantable Cardioverter-Defibrillators
    Rutzen-Lopez H.
    Silva J.
    Helm R.H.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (8)
  • [32] Recommendations for cardiacmagnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators
    von Knobelsdorff-Brenkenhoff, F.
    Bauer, W. R.
    Deneke, T.
    Fleck, E.
    Rolf, A.
    Schulz-Menger, J.
    Sommer, P.
    Tillmanns, C.
    Eitel, I.
    KARDIOLOGE, 2019, 13 (02): : 75 - 86
  • [33] Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators
    Chamis, AL
    Peterson, GE
    Cabell, CH
    Corey, GR
    Sorrentino, RA
    Greenfield, RA
    Ryan, T
    Reller, LB
    Fowler, VG
    CIRCULATION, 2001, 104 (09) : 1029 - 1033
  • [34] Treatment of patients with cardiac pacemakers and implantable cardioverter-defibrillators during radiotherapy
    Solan, AN
    Solan, MJ
    Bednarz, G
    Goodkin, MB
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 897 - 904
  • [35] A comparison of psychosocial adaptation and acceptance in patients with pacemakers and implantable cardioverter-defibrillators
    Büchi, S
    Klaghofer, R
    Duru, F
    Candinas, R
    Buddeberg, C
    JOURNAL OF PSYCHOSOMATIC RESEARCH, 2000, 48 (03) : 282 - 282
  • [36] TREATMENT OF VENTRICULAR TACHYARRHYTHMIAS IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS AND ANTITACHYCARDIA PACEMAKERS
    WINTERS, SL
    CAMUNAS, J
    ERGIN, A
    ESTIOKO, M
    GOMES, JA
    CURRENT OPINION IN CARDIOLOGY, 1989, 4 (04) : 555 - 558
  • [37] Aspergillus infection of implantable cardioverter-defibrillators and pacemakers:: case report and literature review
    Cobo, M.
    Ramos, A.
    Toquero, J.
    Munez, E.
    Alvarez-Espejo, T.
    Munoz, M.
    Fernandez, I.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2007, 26 (05) : 357 - 361
  • [38] Aspergillus infection of implantable cardioverter-defibrillators and pacemakers: case report and literature review
    M. Cobo
    A. Ramos
    J. Toquero
    E. Muñez
    T. Alvárez-Espejo
    M. Muñoz
    I. Fernández
    European Journal of Clinical Microbiology & Infectious Diseases, 2007, 26 : 357 - 361
  • [39] Implantable cardioverter-defibrillators in arrhythmias: a rapid and systematic review of effectiveness
    Parkes, J
    Bryant, J
    Milne, R
    HEART, 2002, 87 (05) : 438 - 442
  • [40] A systematic review of the use of magnetic resonance imaging in non-conditional pacemakers and implantable defibrillators
    Murphy, R.
    Kerley, R. K.
    Kearney, P. K.
    EUROPEAN HEART JOURNAL, 2021, 42 : 229 - 229