Fully automated determination of selective retinoic acid receptor ligands in mouse plasma and tissue by reversed-phase liquid chromatography coupled on-line with solid-phase extraction

被引:16
|
作者
Arafa, HMM
Hamada, FMA
Elmazar, MMA
Nau, H
机构
[1] AL-AZHAR UNIV,COLL PHARM,CAIRO,EGYPT
[2] KING SAUD UNIV,COLL PHARM,RIYADH,SAUDI ARABIA
关键词
sample preparation; retinoids; retinol;
D O I
10.1016/0021-9673(95)00980-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully automated reversed-phase HPLC method was developed for the quantitative assay of three retinoids (Am-580, CD-2019 and CD-437) which selectively activate the retinoic acid receptors RAR alpha, RAR beta and RAR gamma, respectively. Mouse plasma, embryo and maternal tissues were prepared for injection by on-line solid-phase extraction (SPE) and valve-switching techniques. Following automatic injection, the sample was loaded on preconditioned disposable cartridges, cleaned-up and then transferred onto the analytical column to be eluted in the backflush mode, separated by gradient elution and detected by UV, while a new cartridge was concomitantly conditioned. The overall recovery was quantitative allowing for external standardization. The calibration curves were linear in all biological samples tested so far, with a correlation coefficient (r) >0.99. The intra-day precision was less than or equal to 7.8% (n=5-6) and the inter-day variability was less than or equal to 9.4% (n=3). The lower limit of detection was 2.5 ng/ml or ng/g for CD-2019 and CD-437, and 5 ng/ml for Am-580 with a SIN ratio of 5 using a sample weight of 25 mu l or mg. The method is now in routine use in our laboratory for the assessment of the pharmacokinetic profiles of these retinoids. The small sample size required, the simple sample prepration and the rapid analysis with high degree of automation make this method convenient for microanalysis of biological samples both in animal and human studies.
引用
收藏
页码:125 / 136
页数:12
相关论文
共 50 条
  • [11] Screening of drugs in equine plasma using automated on-line solid-phase extraction coupled with liquid chromatography tandem mass spectrometry
    Kwok, W. H.
    Leung, David K. K.
    Leung, Gary N. W.
    Wan, Terence S. M.
    Wong, Colton H. F.
    Wong, Jenny K. Y.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (19) : 3289 - 3296
  • [12] Determination of sulfonamides in serum by on-line solid-phase extraction coupled to liquid chromatography with photoinduced fluorescence detection
    Arroyo-Manzanares, Natalia
    Lara, Francisco J.
    Airado-Rodriguez, Diego
    Gamiz-Gracia, Laura
    Garcia-Campana, Ana M.
    TALANTA, 2015, 138 : 258 - 262
  • [13] ANALYSIS OF ZAPRINAST IN RAT AND HUMAN PLASMA BY AUTOMATED SOLID-PHASE EXTRACTION AND REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PICOT, VS
    DOYLE, E
    PEARCE, JC
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (02): : 454 - 460
  • [14] Reversed-phase liquid chromatography coupled on-line to receptor affinity detection based on the human estrogen receptor
    Oosterkamp, AJ
    Herraiz, MTV
    Irth, H
    Tjaden, UR
    vanderGreef, J
    ANALYTICAL CHEMISTRY, 1996, 68 (07) : 1201 - 1206
  • [15] Fully automated determination of eserine N-oxide in human plasma using on-line solid-phase extraction with liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Pruvost, A
    Ragueneau, I
    Ferry, A
    Jaillon, P
    Grognet, JM
    Benech, H
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (05): : 625 - 633
  • [16] Determination of four fluoroquinolones in milk by on-line immunoaffinity capture coupled with reversed-phase liquid chromatography
    Holtzapple, CK
    Buckley, SA
    Stanker, LH
    JOURNAL OF AOAC INTERNATIONAL, 1999, 82 (03) : 607 - 613
  • [17] Determination of four fluoroquinolones in milk by on-line immunoaffinity capture coupled with reversed-phase liquid chromatography
    Holtzapple, Carol K.
    Buckley, Sandra A.
    Stanker, Larry H.
    Journal of AOAC International, 82 (03): : 607 - 613
  • [18] Solid-phase extraction or liquid chromatography coupled on-line with gas chromatography in the analysis of biological samples
    Hyötyläinen, T
    Riekkola, ML
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (01): : 13 - 21
  • [19] Determination of alkylphenols and alkylphenol polyethoxylates by reversed-phase high-performance liquid chromatography and solid-phase extraction
    Takuma Takasu
    Alexander Iles
    Kiyoshi Hasebe
    Analytical and Bioanalytical Chemistry, 2002, 372 : 554 - 561
  • [20] Quantification of myrislignan in rat plasma by solid-phase extraction and reversed-phase high-performance liquid chromatography
    Li, Fei
    Yang, Xiuwei
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (06) : 601 - 605