Influence of solvent properties on separation and detection performance in non-aqueous capillary electrophoresis-mass spectrometry of basic analytes

被引:22
|
作者
Steiner, F [1 ]
Hassel, M [1 ]
机构
[1] Univ Saarland, D-66041 Saarbrucken, Germany
关键词
solvents properties; nonaqueous capillary electrophoresis; selectivity control; separation speed; peak efficiency;
D O I
10.1016/j.chroma.2004.11.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The versatility of non-aqueous capillary electrophoresis (NACE) results mainly from the variety of physico-chemical properties of the different solvents. They provide solubility for a wide range of analytes, enable to control electrophoretic selectivity, but affect in some cases UV absorbance detection. The coupling of NACE to electrospray mass spectrometry (ESI-MS) allows to cope with the high UV cut-off of some CE relevant solvents (e.g., formamides). In this paper the pure organic solvents methanol, acetonitrile, dimethylsulfoxide, formamide, N-methylformamide and N,N-dimethylformamide are evaluated against water for the preparation of ammonium acetate electrolytes to separate the basic model substances 2-aminobenzimidazole, procaine, propranolol and quinine with NACE-MS. MS coupling is assisted with the sheath liquid water-isopropanol (1:4, v/v) with 0.1% formic acid. The goal of the paper is to assess the influence of the solvent on selectivity, separation speed, and peak efficiency for a given set of model compounds on a simple empirical basis. It should give the user an idea how the separation quality is changed when nothing but the running solvent is altered. The obtained efficiency results were discussed with respect to physico-chemical models described in literature (assuming longitudinal diffusion as the only source of band broadening), but no satisfying correlations with solvent properties could be traced. The feasibility of all six organic solvents for MS coupling was demonstrated and the influence of the separation solvent on the MS detection performance was compared. In the seven different solvents, the shortest run time was obtained with acetonitrile, the best peak resolution with the amphiprotic solvents (especially methanol) best peak efficiency with methanol and formamide, and the most sensitive ESI-MS detection with acetonitrile and methanol, but with only slight advantage to water. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:131 / 142
页数:12
相关论文
共 50 条
  • [31] Nonaqueous capillary electrophoresis-mass spectrometry for separation of venlafaxine and its phase I metabolites
    Cherkaoui, S
    Rudaz, S
    Veuthey, JL
    ELECTROPHORESIS, 2001, 22 (03) : 491 - 496
  • [32] Potentialities of electrochemical detection in conjunction with non-aqueous capillary electrophoresis
    Matysik, FM
    ELECTROCHIMICA ACTA, 1998, 43 (23) : 3475 - 3482
  • [33] Indirect detection of organic acids in non-aqueous capillary electrophoresis
    Chen, MJ
    Chen, HS
    Lin, CY
    Chang, HT
    JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) : 171 - 180
  • [34] Electrostatic interaction mechanism on the separation of phenols by non-aqueous capillary electrophoresis
    Wei WeiLi
    Yin YongGuang
    Xia ZhiNing
    Chen ZhiTao
    Liu Weiqi
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 2007, 50 (01): : 47 - 53
  • [35] Separation Analysis of Reactive Chemical Species by Non-Aqueous Capillary Electrophoresis
    Esaka, Yukihiro
    Okumura, Noriko
    Uno, Bunji
    BUNSEKI KAGAKU, 2008, 57 (12) : 961 - 968
  • [36] Electrostatic interaction mechanism on the separation of phenols by non-aqueous capillary electrophoresis
    WeiLi Wei
    YongGuang Yin
    ZhiNing Xia
    ZhiTao Chen
    WeiQi Liu
    Science in China Series B: Chemistry, 2007, 50 : 47 - 53
  • [37] Use of metal complexation in non-aqueous capillary electrophoresis systems for the separation and improved detection of tetracyclines
    Tjornelund, J
    Hansen, SH
    JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) : 235 - 243
  • [38] Electrostatic interaction mechanism on the separation of phenols by non-aqueous capillary electrophoresis
    WEI WeiLi 1
    2Research Center for Eco-Environmental Science
    3Key Laboratory for Biomechanics&Tissue Engineering of Ministry of Education
    Science in China(Series B:Chemistry), 2007, (01) : 47 - 53
  • [39] Non-aqueous capillary electrophoresis for the analysis of acidic compounds using negative electrospray ionization mass spectrometry
    Bonvin, Gregoire
    Schappler, Julie
    Rudaz, Serge
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1323 : 163 - 173
  • [40] Analysis of neutral surfactants by non-aqueous medium capillary electrophoresis hyphenated to mass spectrometry (ion trap)
    Morin, C. J.
    Geulin, L.
    Mofaddel, N.
    Desbene, A. M.
    Desbene, P. L.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1198 (1-2) : 226 - 231