Design and application of an assessment protocol for electromagnetic tracking systems

被引:106
|
作者
Hummel, JB [1 ]
Bax, MR
Figl, ML
Kang, Y
Maurer, C
Birkfellner, WW
Bergmann, H
Shahidi, R
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, Vienna, Austria
[2] Stanford Univ, Sch Med, Image Guidance Labs, Stanford, CA 94305 USA
[3] Ludwig Boltzmann Inst Nucl Med & Endocrinol, Vienna, Austria
基金
奥地利科学基金会;
关键词
D O I
10.1118/1.1944327
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper defines a simple protocol for competitive and quantified evaluation of electromagnetic tracking systems such as the NDI Aurora (A) and Ascension microBIRD with dipole transmitter (B). It establishes new methods and a new phantom design which assesses the reproducibility and allows comparability with different tracking systems in a consistent environment. A machined base plate was designed and manufactured in which a 50 mm grid of holes was precisely drilled for position measurements. In the center a circle of 32 equispaced holes enables the accurate measurement of rotation. The sensors can be clamped in a small mount which fits into pairs of grid holes on the base plate. Relative positional/orientational errors are found by subtracting the known distances/ rotations between the machined locations from the differences of the mean observed positions/ rotation. To measure the influence of metallic objects we inserted rods made of steel (SST 303, SST 416), aluminum, and bronze into the sensitive volume between sensor and emitter. We calculated the fiducial registration error and fiducial location error with a standard stylus calibration for both tracking systems and assessed two different methods of stylus calibration. The positional jitter amounted to 0.14 mm(A) and 0.08 mm(B). A relative positional error of 0.96 mm +/- 0.68 mm, range -0.06 mm; 2.23 mm(A) and 1.14 mm 0.78 mm, range -3.72 min; 1.57 mm(B) for a given distance of 50 mm was found. The relative rotation error was found to be 0.51 degrees (A)/0.04 degrees (B). The most relevant distortion caused by metallic objects results from SST 416. The maximum error 4.2 mm(A) / >= 100 min(B) occurs when the rod is close to the sensor(20 mm). While (B) is more sensitive with respect to metallic objects, (A) is less accurate concerning orientation measurements. (B) showed a systematic error when distances are calculated. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:2371 / 2379
页数:9
相关论文
共 50 条
  • [21] Application of Early Sustainability Assessment to Support the Design of Industrial Systems
    Peruzzini, Margherita
    Pellicciari, Marcello
    INDUSTRIAL ENGINEERING AND MANAGEMENT SYSTEMS, 2018, 17 (02): : 209 - 225
  • [22] Design of a variable structure PI controller and its application in photoelectronic tracking systems
    Xiong A.
    Fan Y.-K.
    Wu Q.-Z.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (08): : 1855 - 1861
  • [23] WAVEFORM DESIGN FOR TRACKING SYSTEMS
    Le, Xinxi
    2015 INTERNATIONAL CONFERENCE ON CYBER-ENABLED DISTRIBUTED COMPUTING AND KNOWLEDGE DISCOVERY, 2015, : 458 - 462
  • [24] Planar On-Silicon Inductor Design for Electromagnetic Tracking
    Sidun, Aleksandr
    Srivastava, Manish
    O'Donoghue, Kilian
    Jaeger, Herman Alexander
    Cavaliere, Marco
    O'Hare, Daniel
    van den Bosch, Christian
    Cantillon-Murphy, Padraig
    IEEE SENSORS JOURNAL, 2023, 23 (18) : 21129 - 21136
  • [25] Design Principles of an Electromagnetic System for Surgical Instrument Tracking
    Grunin L.Y.
    Rozhentsov A.A.
    Khalimov M.
    Bulletin of the Russian Academy of Sciences: Physics, 2018, 82 (12) : 1522 - 1524
  • [26] Electromagnetic Tracking System Design for Location and Orientation Estimation
    Wu, Yi-Chin
    Ma, His-Yen
    Kuo, Zhong-Hsiang
    Teng, Megan
    Lin, Chun-Yeon
    2022 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2022, : 1256 - 1262
  • [27] Design and Development of an Electromagnetic Micropower Generator for Activity Tracking
    Kirolos, Andrew
    Moustafa, Ahmed
    El-Badawy, Ayman
    Habib, Mohamed
    Mohamed, Ramy
    Soliman, Mostafa
    Abdel-Rahman, Eihab
    2018 TWENTIETH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2018, : 522 - 527
  • [28] Bronchoscopy Navigation beyond Electromagnetic Tracking Systems: A Novel Bronchoscope Tracking Prototype
    Luo, Xiongbiao
    Kitasaka, Takayuki
    Mori, Kensaku
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 194 - +
  • [29] Planar Magnetic Shielding for Use With Electromagnetic Tracking Systems
    O'Donoghue, Kilian
    Cantillon-Murphy, Padraig
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (02) : 8500112
  • [30] An economic assessment of the Kyoto Protocol application
    Dagoumas, AS
    Papagiannis, GK
    Dokopoulos, PS
    ENERGY POLICY, 2006, 34 (01) : 26 - 39