ELECTRODE-SKIN IMPEDANCE COMPONENT ESTIMATION IN THE TIME-DOMAIN

被引:0
|
作者
Fortune, Benjamin C. [1 ]
McKenzie, Lachlan R. [1 ]
Chatfield, Logan T. [1 ]
Pretty, Christopher G. [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Ctr Bioengn, Christchurch, New Zealand
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a method to estimate the individual component values of a bipolar electrode-skin interface, with future intent of applying compensatory electrode-skin impedance balancing prior recording bio-signals with electromyography. The electrode-skin interface was stimulated by a step input and the output behaviour was characterised using a single exponential model per electrode. The method was applied to simulated circuitry, passive component circuitry and a human subject. The accuracy of the method was determined using the known values that comprised the simulated and passive component circuitry. Nine of ten simulated data sets resulted in accurate estimations, with a maximum error of 0.763% and a mean error of 0.076% per component. The method also produced successful estimates for nine of the ten physical circuitry data sets, with a maximum error of 10.2% and a mean error of 3.49% per component. The method was unsuccessful in estimating the individual electrode skin impedance components for the human subject: this was due to the system failing to reach steady state during the stimulation period. The authors suspect a DC offset caused by the half-cell potentials associated with the electrode-skin interface were the cause of the unexpected behaviour.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Broadband time-domain impedance models
    Fung, K.-Y. (mmkyfung@polyu.edu.hk), 1600, American Inst. Aeronautics and Astronautics Inc. (39):
  • [22] Broadband time-domain impedance models
    Fung, KY
    Ju, HB
    AIAA JOURNAL, 2001, 39 (08) : 1449 - 1454
  • [23] Impedance and its time-domain extensions
    Fung, KY
    Ju, HB
    Tallapragada, B
    AIAA JOURNAL, 2000, 38 (01) : 30 - 38
  • [24] A 2.4μA Continuous-time Electrode-Skin Impedance Measurement Circuit For Motion Artifact Monitoring in ECG Acquisition Systems
    Kim, Sunyoung
    Yazicioglu, Refet Firat
    Torfs, Tom
    Dilpreet, Buxi
    Julien, Penders
    Van Hoof, Chris
    2010 SYMPOSIUM ON VLSI CIRCUITS, DIGEST OF TECHNICAL PAPERS, 2010, : 219 - +
  • [25] Study into the repeatability of the electrode-skin interface utilizing electrodes commonly used in Electirical Impedance Tomography
    Wang, W.
    Wang, L.
    Qiao, G.
    Prickett, P.
    Bramer, B.
    Tunstall, B.
    Ai-Akaidi, M.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 336 - +
  • [26] Time-domain simulation of acoustic impedance tubes
    Pasqual, Alexander Mattioli
    Lara, Luana Torquete
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2017, 39 (01) : 67 - 79
  • [27] Time-domain simulation of acoustic impedance tubes
    Alexander Mattioli Pasqual
    Luana Torquete Lara
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2017, 39 : 67 - 79
  • [28] On the Limitations of the Time-Domain Impedance Boundary Condition
    Stumpf, Martin
    Vandenbosch, Guy A. E.
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2013, 61 (12) : 6094 - 6099
  • [29] A review of time-domain impedance modelling and applications
    Richter, Christoph
    Hay, Junis Abdel
    Panek, Lukasz
    Schoenwald, Norbert
    Busse, Stefan
    Thiele, Frank
    JOURNAL OF SOUND AND VIBRATION, 2011, 330 (16) : 3859 - 3873
  • [30] The use of hydrogel as an electrode-skin interface for electrode array FES applications
    Cooper, Glen
    Barker, Anthony T.
    Heller, Ben W.
    Good, Tim
    Kenney, Laurence P. J.
    Howard, David
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (08): : 967 - 972