Accuracy of remote continuous respiratory rate monitoring technologies intended for low care clinical settings: a prospective observational study

被引:0
|
作者
van Loon, Kim [1 ]
Peelen, Linda M. [1 ,2 ]
van de Vlasakker, Emmy C. [1 ]
Kalkman, Cor J. [1 ]
van Wolfswinkel, Leo [1 ]
van Zaane, Bas [1 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Dept Anesthesiol Intens Care & Emergency Med, POB 85500, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht, Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
关键词
ANTECEDENTS; AGREEMENT; ARREST;
D O I
10.1007/s12630-018-1214-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
PurposeAltered respiratory rate (RR) has been identified as an important predictor of serious adverse events during hospitalization. Introduction of a well-tolerated continuous RR monitor could potentially reduce serious adverse events such as opioid-induced respiratory depression. The purpose of this study was to investigate the ability of different monitor devices to detect RR in low care clinical settings.MethodsThis was a prospective method-comparison study with a cross-sectional design. Thoracic impedance pneumography (IPG), frequency modulated continuous wave radar, and an acoustic breath sounds monitor were compared with the gold standard of capnography for their ability to detect RR in breaths per minute (breaths min( -1)) in awake postoperative patients in the postanesthesia care unit. The Bland and Altman method for repeated measurements and mixed effect modelling was used to obtain bias and limits of agreement (LoA). Furthermore, the ability of the three devices to assist with correct treatment decisions was evaluated in Clarke Error Grids.ResultsTwenty patients were monitored for 1,203 min, with a median [interquartile range] of 61 [60-63] min per patient. The bias (98.9% LoA) were 0.1 (-7.9 to 7.9) breaths min( -1) for the acoustic monitor, -1.6 (-10.8 to 7.6) for the radar, and -1.9 (-13.1 to 9.2) for the IPG. The extent to which the monitors guided adequate or led to inadequate treatment decisions (determined by Clarke Error Grid analysis) differed significantly between the monitors (P = 0.011). Decisions were correct 96% of the time for acoustic, 95% of the time for radar, and 94% of the time for IPG monitoring devices.ConclusionsNone of the studied devices (acoustic, IPG, and radar monitor) had LoA that were within our predefined (based on clinical judgement) limits of 2 breaths min( -1). The acoustic breath sound monitor predicted the correct treatment more often than the IPG and the radar device.
引用
收藏
页码:1324 / 1332
页数:9
相关论文
共 33 条
  • [21] Continuous Monitoring of Changes in Heart Rate during the Periprocedural Course of Carotid Artery Stenting Using a Wearable Device: A Prospective Observational Study
    Hirai, Kentaro
    Fujimoto, Yasunori
    Bamba, Yohei
    Kageyama, Yu
    Ima, Hiroyuki
    Ichise, Ayaka
    Sasaki, Hanako
    Nakagawa, Ryota
    NEUROLOGIA MEDICO-CHIRURGICA, 2023, 63 (11) : 526 - 534
  • [22] Clinical Feasibility of Monitoring Resting Heart Rate Using a Wearable Activity Tracker in Patients With Thyrotoxicosis: Prospective Longitudinal Observational Study
    Lee, Jie-Eun
    Lee, Dong Hwa
    Oh, Tae Jung
    Kim, Kyoung Min
    Choi, Sung Hee
    Lim, Soo
    Park, Young Joo
    Park, Do Joon
    Jang, Hak Chul
    Moon, Jae Hoon
    JMIR MHEALTH AND UHEALTH, 2018, 6 (07):
  • [23] A multicenter, prospective, observational study to assess the satisfaction of an integrated digital platform of online medical care and remote patient monitoring in Parkinson's disease
    Shiraishi, Makoto
    Kamo, Tsutomu
    Kumazawa, Ryuya
    Sasaki, Naoshi
    Isahaya, Kenji
    Akiyama, Hisanao
    Furusawa, Yoshihiko
    Onodera, Reiko
    Fernandez, Jovelle
    Otsuka, Masaru
    Yamano, Yoshihisa
    NEUROLOGY AND CLINICAL NEUROSCIENCE, 2023, 11 (03): : 152 - 163
  • [24] Clinical course and long-term outcome in children with alteration of consciousness underwent continuous EEG monitoring: A prospective observational study in Thailand
    Fangsaad, Thitiporn
    Assawabumrungkul, Siriluk
    Visudtibhan, Anannit
    JOURNAL OF CLINICAL NEUROSCIENCE, 2018, 47 : 93 - 96
  • [25] CLINICAL FINDINGS AND OUTCOMES FROM 1306 PATIENTS WITH COVID-19 PNEUMONIA IN AN INTERMEDIATE RESPIRATORY CARE UNIT: A PROSPECTIVE, OBSERVATIONAL STUDY
    Escudero, D. Laorden
    Teran-Tinedo, J. R.
    Gholamian-Ovejero, S.
    Lorente-Gonzalez, M.
    Zevallos-Villegas, A.
    Martinez-Alejos, R.
    Neria, F.
    Ortega-Fraile, M. A.
    Hernandez-Nunez, J.
    Mariscal-Aguilar, P.
    Navarro-Casado, R.
    De La Calle-Gil, I
    Plaza-Moreno, M. C.
    Funes-Moreno, C.
    Cano-Sanz, E.
    Suarez-Ortiz, M.
    Valle-Falcones, M.
    Carballo-Lopez, D.
    Gallego-Rodriguez, B.
    Calderon-Alcala, M.
    Latif-Essa, A.
    Churruca-Arrospide, M.
    Saiz-Lou, E. M.
    Rodriguez-Calle, C.
    Falcone, A.
    Salvador-Maya, M. A.
    Martin-Torres, J.
    Borderia, M. D. Espuelas
    Cotter-Munoz, L.
    Sanchez-Azofra, A.
    Vates-Gomez, R.
    Garcia-Prieto, F.
    Hernandez-Piriz, A.
    Villen-Villegas, T.
    Landete, P.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [26] The Clinical Utility of Continuous QT Interval Monitoring in Patients Admitted With COVID-19 Compared With Standard of Care: A Prospective Cohort Study
    Alqarawi, Wael
    Birnie, David H.
    Golian, Mehrdad
    Nair, Girish M.
    Nery, Pablo B.
    Klein, Andres
    Davis, Darryl R.
    Sadek, Mouhannad M.
    Neilipovitz, David
    Johnson, Christopher B.
    Green, Martin S.
    Redpath, Calum
    CJC OPEN, 2020, 2 (06) : 592 - 598
  • [27] Investigating the application of motion accelerometers as a sleep monitoring technique and the clinical burden of the intensive care environment on sleep quality: study protocol for a prospective observational study in Australia
    Delaney, Lori J.
    Currie, Marian J.
    Huang, Hsin-Chia Carol
    Litton, Edward
    Wibrow, Bradley
    Lopez, Violeta
    Van Haren, Frank
    BMJ OPEN, 2018, 8 (01):
  • [28] CLINICAL PHARMACIST ASSESSMENT OF MONITORING AND RESOLVING THE DRUG-RELATED PROBLEMS IN BIPOLAR DISORDER PATIENTS: A PROSPECTIVE, OBSERVATIONAL STUDY AT TERTIARY CARE TEACHING HOSPITAL
    Parihar, Ashish Singh
    Ganachari, Madiwalayya S.
    Tekkalaki, Bheemsain, V
    Patil, Sandeep C.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2019, 10 (06): : 2790 - 2796
  • [29] The optimal duration of continuous respiratory rate monitoring to predict in-hospital mortality within seven days of admission - A pilot study in a low resource setting
    Sikakulya, Franck Katembo
    Nakitende, Immaculate
    Nabiryo, Joan
    Pakdel, Rezvan
    Namuleme, Sylivia
    Lumala, Alfred
    Kellett, John
    RESUSCITATION PLUS, 2024, 20
  • [30] A prospective observational real world feasibility study assessing the role of app-based remote patient monitoring in reducing primary care clinician workload during the COVID pandemic
    Shah, Sachin Shailendra
    Safa, Afsana
    Johal, Kuldhir
    Obika, Dillon
    Valentine, Sophie
    BMC FAMILY PRACTICE, 2021, 22 (01) : 248