How Useful is Contrast Enhanced Ultrasonography for the Characterization of Focal Liver Lesions?

被引:0
|
作者
Sporea, Ioan [1 ]
Sirli, Roxana [1 ]
Martie, Alina [1 ]
Popescu, Alina [1 ]
Danila, Mirela [1 ]
机构
[1] Univ Med & Pharm, Dept Gastroenterol & Hepatol, Timisoara, Romania
关键词
Contrast enhanced ultrasound; focal liver lesions; contrast agent; liver cirrhosis; ULTRASOUND CEUS; GUIDELINES; SONOVUE; AGENT; CT;
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Aim: Focal liver lesions (FLLs) are quite frequently discovered in daily practice at routine ultrasound. The aim of our study is to present a single centre experience concerning the use of contrast enhanced ultrasound (CEUS) in the characterization of FLL and to find when one can avoid using other expensive imaging modalities such as contrast enhanced CT or MRI. Method: We performed a prospective, single centre study during September 2009 - April 2010, and we evaluated 379 FLLs. A CEUS examination was considered conclusive if the FLL had a typical enhancement pattern according to the EFSUMB guidelines. Results: From the 379 cases with FLL, 198 (52.2%) were patients without known liver disease and 181 (47.8%) with known chronic liver disease (156 had cirrhosis, 25 chronic hepatitis); in 296/379 cases (78.1%) CEUS was conclusive. CEUS allowed the positive diagnosis of benign vs. malignant lesion in 261/294 (88.8%) de novo FLLs (CEUS performed for the first time), while in 33 (11.2%) cases it was inconclusive and could not differentiate between benign or malignant lesions. The CEUS results included 129 (49.4%) benign lesions and 132 (50.6%) malignant. Conclusion: CEUS was conclusive in approximately 80% of the FLLs and the benign or malignant character of a lesion was demonstrated in about 90% of cases. Thus, when faced with an uncharacteristic FLL on standard ultrasound examination, our local strategy is to perform CEUS as a first-line investigation, thus avoiding other expensive examinations.
引用
收藏
页码:393 / 398
页数:6
相关论文
共 50 条
  • [21] ACCURACY OF CONTRAST ENHANCED ULTRASOUND IN CHARACTERIZATION OF FOCAL LIVER LESIONS
    Monteiro, Sara
    Magalhaes, Joana
    Leite, Slvia
    de Castro, Francisca Dias
    Carvalho, Pedro Boal
    Marinho, Carla M.
    Cotter, Jose
    GASTROENTEROLOGY, 2017, 152 (05) : S1184 - S1184
  • [22] CHARACTERIZATION OF FOCAL LIVER LESIONS WITH CONTRAST-ENHANCED ULTRASOUND
    Piscaglia, Fabio
    Lencioni, Riccardo
    Sagrini, Elisabetta
    Pina, Clotilde Dalla
    Cioni, Dania
    Vidili, Giampaolo
    Bolondi, Luigi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (04): : 531 - 550
  • [23] Role of contrast enhanced ultrasound in characterization of focal liver lesions
    Thakur, Shruti
    Jhobta, Anupam
    Dhiman, D. S.
    Sood, R. G.
    Chauhan, Arun
    Thakur, Charu S.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (01): : 7 - 17
  • [24] Contrast-enhanced ultrasonography in the characterization of benign focal liver lesions: activity-based cost analysis
    Faccioli, N.
    D'Onofrio, M.
    Comai, A.
    Cugini, C.
    RADIOLOGIA MEDICA, 2007, 112 (06): : 810 - 820
  • [25] Contrast-enhanced ultrasonography as a method of monitoring focal liver lesions - initial report
    Dobek, Adam
    Kobierecki, Mateusz
    Wieczorek, Patryk
    Grzasiak, Oliwia
    Ciesielski, Wojciech
    Fabisiak, Adam
    Stefanczyk, Ludomir
    CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2024, 10 (02) : 120 - 128
  • [26] Detection and characterization of focal liver lesions with contrast-enhanced ultrasonography in patients with hepatitis C-induced liver cirrhosis
    Rahbin, N.
    Siosteen, A. -K.
    Elvin, A.
    Blomqvist, L.
    Hagen, K.
    Hultcrantz, R.
    Aleman, S.
    ACTA RADIOLOGICA, 2008, 49 (03) : 251 - 257
  • [27] Malignant focal liver lesions at contrast-enhanced ultrasonography and magnetic resonance with hepatospecific contrast agent
    D'Onofrio, M.
    Crosara, S.
    De Robertis, R.
    Canestrini, S.
    Cantisani, V.
    Morana, G.
    Mucelli, R. Pozzi
    ULTRASOUND, 2014, 22 (02) : 91 - 98
  • [28] Contrast-enhanced ultrasonography in the characterization of benign focal hepatic lesions: Spectrum of findings
    Bartolotta, TV
    Midiri, M
    Galia, M
    Mamone, G
    Carcione, A
    De Maria, M
    Lagalla, R
    PROCEEDINGS OF THE 23RD INTERNATIONAL CONGRESS OF RADIOLOGY OF THE INTERNATIONAL SOCIETY OF RADIOLOGY, 2004, : 499 - 501
  • [29] OPTIMIZED CONTRAST-ENHANCED ULTRASONOGRAPHY FOR CHARACTERIZATION OF FOCAL LIVER LESIONS IN CIRRHOSIS: A SINGLE-CENTER RETROSPECTIVE STUDY
    De Sio, I.
    Iadevaia, M.
    Del Prete, A.
    Vitale, L. M.
    Niosi, M.
    Meucci, R.
    De Sio, C.
    Romano, L.
    Federico, A.
    Loguercio, C.
    Romano, M.
    DIGESTIVE AND LIVER DISEASE, 2014, 46 : S120 - S120
  • [30] Characterization of focal liver lesions using sulphur hexafluoride (SF6) microbubble contrast-enhanced ultrasonography
    Mohamed Gamal El-Din Mansour
    Mona Hussein Abdel Kader
    Hanan Mahmoud Arafa
    Susan Adil Ali
    Egyptian Journal of Radiology and Nuclear Medicine, 52