Design and control of autonomous hybrid wind solar system with DFIG supplying three-phase four-wire loads

被引:5
|
作者
Kumar, Arjun [1 ]
Shivashankar [1 ]
Keshavamurthy [1 ]
机构
[1] Sri Venkateshwara Coll Engn, Dept Elect & Commun Engn, Bengaluru 562157, Karnataka, India
关键词
Autonomous Hybrid Wind Solar System (AHWSS); Doubly Fed Induction Generator (DFIG); Solar Photovoltaic (SPV) Array; Vector control; PERFORMANCE ENHANCEMENT; CAPABILITY; ALGORITHM; RIDE;
D O I
10.1016/j.asej.2020.11.027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the design, control and evaluation of an Autonomous Hybrid Wind Solar System (AHWSS) energy system feeding into three-phase, four-line loads and an array of batteries. Wind Energy Conversion System Connected to the Grid (WECS) contains Doubly Fed Induction Generator (DFIG) and two PWM voltage source converters i.e. Grid Side Converter (GSC) and Rotor Side Converter (RSC) connected back to back at DC-link and are provided with an algorithm for Maximum Power Point Tracking (MPPT). The grid voltage-oriented control algorithm is used to maintain a steady DC bus voltage for the GSC and to balance the reactive power at the power grid even the divergence in frequency and voltage can be regulated with this novel approach. The stator voltage-orientated vector control is implemented in the RSC control strategy, delivering effective controlling of active and reactive power at the stator, and also a MPPT is achieved through controlling the Tip Speed Ratio. The photovoltaic (PV) system along with the boost converter is fed to the DC link. A Perturb & Observe method is used for tracking maximum power in a solar PV system. The model is implemented in MATLAB's Sim-power system toolkit with ode3 solver and is presented in different scenarios, e.g., solar irradiation, differing wind velocity, dynamic, and unbalanced nonlinear loads. In these all constraints, DFIG's stator winding currents are balanced with low Total Harmonics Distortion (THD), value less than 4% in all scenarios. (C) 2021 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Ain Shams University.
引用
收藏
页码:2875 / 2890
页数:16
相关论文
共 50 条
  • [41] Active Power Filtering for a Three-Phase Four-Wire Network with Unidentifiable Harmonic Loads
    Waite, M. J.
    Zhang, L.
    Chong, B.
    2011 2ND IEEE PES INTERNATIONAL CONFERENCE AND EXHIBITION ON INNOVATIVE SMART GRID TECHNOLOGIES (ISGT EUROPE), 2011,
  • [42] Control strategy of three-phase voltage source PWM rectifier in three-phase four-wire systems
    Beijing Jiaotong University, Beijing 100044, China
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (07): : 64 - 68
  • [43] Three-Phase Four-Wire Inverters Based on Cascaded Three-Phase Converters with Four and Three Legs
    Mello, Joao P. R. A.
    Jacobina, Cursino B.
    Correa, Mauricio B. R.
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [44] Three-Phase Four-Wire Inverters Based on Cascaded Three-Phase Converters With Four and Three Legs
    Ramos Agra Mello, Joao Paulo
    Jacobina, Cursino Brandao
    de Rossiter Correa, Mauricio Beltrao
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (06) : 5539 - 5552
  • [45] Active power filter for harmonic and reactive power compensation in three-phase, four-wire systems supplying non-linear loads
    Singh, B
    Al-Haddad, K
    Chandra, A
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1998, 8 (02): : 139 - 145
  • [46] Dynamic model and controller design for active power filter in three-phase four-wire system
    1600, Science and Engineering Research Support Society (07):
  • [47] Performance of Voltage and Frequency Controller in Isolated Wind Power Generation for a Three-Phase Four-Wire System
    Sharma, Shailendra
    Singh, Bhim
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (12) : 3443 - 3452
  • [48] Enhancing power quality with optimized PI controller in three-phase four-wire wind energy system
    Dawar, Bindra
    Arya, Sabha Raj
    Chilipi, Rajasekharareddy
    ELECTRICAL ENGINEERING, 2024,
  • [49] An efficient control system of shunt active power filter in three-phase four-wire power system
    School of Electricity and Information Engineering, Beijing University of Civil Engineering and Architecture, Beijing, China
    不详
    Int. J. Control Autom., 9 (275-290):
  • [50] Characteristics and location of the Quality Control Center using three-phase four-wire ac system
    Ise, T
    Hayashi, Y
    Tsuji, K
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 661 - 666