Design and Computational Evaluation of a Pediatric MagLev Rotary Blood Pump

被引:10
|
作者
Tompkins, Landon H. [1 ]
Gellman, Barry N. [2 ]
Morello, Gino F. [3 ]
Prina, Steven R. [4 ]
Roussel, Thomas J. [1 ]
Kopechek, Jonathan A. [1 ]
Petit, Priscilla C. [2 ]
Slaughter, Mark S. [5 ]
Koenig, Steven C. [1 ,5 ]
Dasse, Kurt A. [1 ,2 ,5 ]
机构
[1] Univ Louisville, Dept Bioengn, Louisville, KY 40202 USA
[2] Inspired Therapeut LLC, 125 E Merritt Isl Cswy,107-341, Merritt Isl, FL 32925 USA
[3] Veritium Res LLC, Ft Lee, NJ USA
[4] BLDC Designs LLC, Rocklin, CA USA
[5] Univ Louisville, Dept Cardiovasc & Thorac Surg, Louisville, KY 40202 USA
基金
美国国家卫生研究院;
关键词
mechanical circulatory support; ventricular assist device; computational fluid dynamics; pediatric; centrifugal pump; VENTRICULAR ASSIST DEVICES; CIRCULATORY SUPPORT; CONTINUOUS-FLOW; FLUID-DYNAMICS; UNITED-STATES;
D O I
10.1097/MAT.0000000000001323
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pediatric heart failure (HF) patients have been a historically underserved population for mechanical circulatory support (MCS) therapy. To address this clinical need, we are developing a low cost, universal magnetically levitated extracorporeal system with interchangeable pump heads for pediatric support. Two impeller and pump designs (pump V1 and V2) for the pediatric pump were developed using dimensional analysis techniques and classic pump theory based on defined performance criteria (generated flow, pressure, and impeller diameter). The designs were virtually constructed using computer-aided design (CAD) software and 3D flow and pressure features were analyzed using computational fluid dynamics (CFD) analysis. Simulated pump designs (V1, V2) were operated at higher rotational speeds (similar to 5,000 revolutions per minute [RPM]) than initially estimated (4,255 RPM) to achieve the desired operational point (3.5 L/min flow at 150 mm Hg). Pump V2 outperformed V1 by generating approximately 30% higher pressures at all simulated rotational speeds and at 5% lower priming volume. Simulated hydrodynamic performance (achieved flow and pressure, hydraulic efficiency) of our pediatric pump design, featuring reduced impeller size and priming volume, compares favorably to current commercially available MCS devices.
引用
收藏
页码:1026 / 1035
页数:10
相关论文
共 50 条
  • [21] Computational fluid dynamics analysis of hydrodynamic bearings of the VentrAssist rotary blood pump
    Qian, Y
    Bertram, CD
    ARTIFICIAL ORGANS, 2000, 24 (06) : 488 - 491
  • [22] Computational Parametric Study of the Axial and Radial Clearances in a Centrifugal Rotary Blood Pump
    Rezaienia, Mohammad Amin
    Paul, Gordon
    Avital, Eldad
    Rothman, Martin
    Korakianitis, Theodosios
    ASAIO JOURNAL, 2018, 64 (05) : 643 - 650
  • [23] A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump
    Arvand, A
    Hormes, M
    Reul, H
    ARTIFICIAL ORGANS, 2005, 29 (07) : 531 - 540
  • [24] Blood transfusion with rotary pump
    Darmady, EM
    BRITISH MEDICAL JOURNAL, 1939, 1939 : 1304 - 1305
  • [25] Blood transfusion with the rotary pump
    Riddell, V
    BRITISH MEDICAL JOURNAL, 1939, 1939 : 1125 - 1129
  • [26] Modeling of a Rotary Blood Pump
    Nestler, Frank
    Bradley, Andrew P.
    Wilson, Stephen J.
    Timms, Daniel L.
    ARTIFICIAL ORGANS, 2014, 38 (03) : 182 - 190
  • [27] DESIGN OF TOTALLY HYDRODYNAMICALLY SUSPENDED IMPELLERS FOR MINIATURIZED ROTARY BLOOD PUMP
    Amaral, F. K.
    Timms, D.
    Bohning, F.
    Graefe, R.
    Schmitz-Rode, T.
    Steinseifer, U.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 425 - 425
  • [28] Analysis of a new PM motor design for a rotary dynamic blood pump
    Xu, LY
    Wang, FX
    Fu, MH
    Medvedev, A
    Smith, WA
    Golding, LAR
    ASAIO JOURNAL, 1997, 43 (05) : M559 - M564
  • [29] OPTIMIZATION OF THE DESIGN OF A ROTARY PUMP
    Alibekov, S. Ya.
    Krasheninnikov, M. V.
    CHEMICAL AND PETROLEUM ENGINEERING, 2013, 49 (7-8) : 539 - 541
  • [30] Evaluation of an index for cardiac function during assistance with a rotary blood pump
    Ogawa, D.
    Tanaka, A.
    Abe, K.
    Olegario, P.
    Kasahara, K.
    Shiraishi, Y.
    Sekine, K.
    Yambe, T.
    Nitta, S.
    Yoshizawa, M.
    FUTURE MEDICAL ENGINEERING BASED ON BIONANOTECHNOLOGY, PROCEEDINGS, 2006, : 1025 - +