Resolution improvement using tapered fiber for a high resolution PET block detector

被引:0
|
作者
Yamamoto, S [1 ]
机构
[1] Kobe City Coll Technol, Nishi Ku, Kobe, Hyogo, Japan
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Tapered fiber optic plate(tapered fiber) is a fiber optic plate which input size and output size is different, One can magnify the light photon image by using the tapered fiber with low light loss. The tapered fiber may be a useful component for a high resolution positron emission tomograph (PET) block detector. Thus, investigations on resolution improvement were performed by using the tapered fiber on a PET block detector. The block detector consists of a scintillator block, a tapered fiber and a position sensitive photomultiplier tube (PSPMT). The light photon image of the scintillator block is magnified by tapered fiber which is optically coupled to the PSPMT. Light loss by using the tapered fiber was 27%. With the taper fiber, scintillator blocks consist of 11x11 matrix of 1.67mm x 1.67 mm x 10mm BGOs as well as 8x8 matrix of 2.0mm x 2.0mm x 10mm were resolved in two dimensional distribution. It is concluded that tapered fiber is one solution for high resolution PET block detectors.
引用
收藏
页码:1442 / 1445
页数:4
相关论文
共 50 条
  • [31] A flexible optical fiber based LGSO DOI block detector for a high resolution integrated PET/MRI system: iPET/MRI-II
    Yamamoto, Seiichi
    Aoki, Masaaki
    Sugiyama, Eiji
    Shimosegawa, Eku
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [32] High-resolution image reconstruction for PET using estimated detector response functions
    Tohme, Michel S.
    Qi, Jinyi
    COMPUTATIONAL IMAGING V, 2007, 6498
  • [33] High resolution β- detector
    Charon, Y.
    Cuzon, J.C.
    Tricoire, H.
    Valentin, L.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 748 - 753
  • [34] Optical fiber readout of scintillator arrays using a multi-channel PMT: a high resolution PET detector for animal imaging
    UCLA Sch of Medicine, Los Angeles, United States
    IEEE Trans Nucl Sci, 3 pt 2 (1932-1937):
  • [35] Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging
    Cherry, SR
    Shao, YP
    Siegel, S
    Silverman, RW
    Mumcuoglu, E
    Meadors, K
    Phelps, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1932 - 1937
  • [36] Increasing PET scanner resolution using a Silicon detector probe
    Brzezinski, K.
    Oliver, J. F.
    Gillam, J.
    Rafecas, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S16 - S17
  • [37] High-resolution PET detector with 100 ps coincidence time resolution using side-by-side phoswich design
    Lee, Min Sun
    Cates, Joshua W.
    Levin, Craig S.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [38] Performance results of a new DOI detector block for a High Resolution PET-LSO Research Tomograph HRRT
    Schmand, M
    Eriksson, L
    Casey, ME
    Andreaco, MS
    Melcher, C
    Wienhard, K
    Flügge, G
    Nutt, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3000 - 3006
  • [39] Performance results of a new DOI detector block for a high resolution PET-LSO research tomograph HRRT
    Schmand, M
    Eriksson, L
    Casey, ME
    Andreaco, MS
    Melcher, C
    Wienhard, K
    Flugge, G
    Nutt, R
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 934 - 938
  • [40] Time resolution of a scintillating fiber detector
    Horikawa, S
    Toeda, T
    Daito, I
    Doushita, N
    Hasegawa, T
    Horikawa, N
    Iwata, T
    Kibe, Y
    Matsuda, T
    Miyachi, Y
    Noboriguchi, K
    Takabayashi, N
    Tohyama, T
    Wakai, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (1-2): : 177 - 184