Electron temperature measurements and electron thermal transport inferences will be critical to the nonactive and deuterium phases of ITER operation and will take on added importance during the alpha heating phase. The diagnostic must meet stringent criteria on spatial coverage and spatial resolution during full field operation. During the early phases of operation, it must operate equally well at half field. The key to the diagnostic is the front end design. It consists of a quasioptical antenna and a pair of calibration sources. The radial resolution of the diagnostic is less than 0.06 m. The spatial coverage extends at least from the core to the separatrix with first harmonic O-mode being used for the core and second harmonic X-mode being used for the pedestal. The instrumentation used for the core measurement at full field can be used for detection at half field by changing the detected polarization. Intermediate fields are accessible. The electron cyclotron emission systems require in situ calibration, which is provided by a novel hot calibration source. The critical component for the hot calibration source, the emissive surface, has been successfully tested. A prototype hot calibration source has been designed, making use of extensive thermal and mechanical modeling. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3496978]
引用
收藏
页数:4
相关论文
共 50 条
  • [21] An Expanded View Electron Cyclotron Emission Imaging (ECEI) Diagnostic
    Kong, Xiangyu
    Domier, Calvin W.
    Yu, Liubing
    Tobias, Benjamin
    Yu, Chang-Xuan
    Luhmann, Neville C., Jr.
    2011 36TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2011,
  • [22] New electron cyclotron emission diagnostic based upon the electron Bernstein wave
    Efthimion, PC
    Hosea, JC
    Kaita, R
    Majeski, R
    Taylor, G
    RADIO FREQUENCY POWER IN PLASMAS, 1999, 485 : 486 - 489
  • [23] EFFECTS OF HARMONIC OVERLAP AND POLARIZATION SCRAMBLING ON ELECTRON CYCLOTRON EMISSION FROM ITER PLASMA
    Danani, S.
    Pandya, Hitesh Kumar B.
    Vasu, P.
    Austin, M. E.
    FUSION SCIENCE AND TECHNOLOGY, 2011, 59 (04) : 651 - 656
  • [24] Electron cyclotron emission diagnostic of high temperature electron cyclotron resonance heated plasmas on Frascati tokamak upgrade
    Zerbini, M
    Buratti, P
    Tudisco, O
    Giruzzi, G
    Bruschi, A
    Cirant, S
    Granucci, G
    Simonetto, A
    Sozzi, C
    Gandini, F
    Pacella, D
    Fournier, KB
    Finkenthal, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 1007 - 1010
  • [25] Electron cyclotron heating and current drive in ITER
    Harvey, RW
    Nevins, WM
    Smith, GR
    Lloyd, B
    OBrien, MR
    Warrick, CD
    NUCLEAR FUSION, 1997, 37 (01) : 69 - 81
  • [26] ELECTRON CYCLOTRON POWER SOURCE SYSTEM FOR ITER
    Rao, S. L.
    Sharma, Anjali
    Sharma, Tarun Kumar
    Kalaria, Parth
    Sharma, Kumar
    Rathod, Vipal
    Shah, Ronak
    Mandge, Deepak
    Joshi, Gaurav
    FUSION SCIENCE AND TECHNOLOGY, 2014, 65 (01) : 129 - 144
  • [27] Proof of principle of Electron Cyclotron Emission as a complementary diagnostic for the plasma position
    Rapson, C. J.
    Denk, S.
    Fischer, R.
    Giannone, L.
    Gude, A.
    Treutterer, W.
    Willensdorfer, M.
    2016 41ST INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2016,
  • [28] Electron cyclotron emission imaging diagnostic system for Rijnhuizen Tokamak Project
    Deng, BH
    Hsia, RP
    Domier, CW
    Burns, SR
    Hillyer, TR
    Luhmann, NC
    Oyevaar, T
    Donné, AJH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 998 - 1001
  • [29] Two-dimensional electron cyclotron emission imaging diagnostic for TEXTOR
    Wang, J
    Domier, CW
    Xia, ZG
    Liang, Y
    Luhmann, NC
    Park, H
    Munsat, T
    Mazzucato, E
    van de Pol, MJ
    Classen, IGJ
    Donné, AJH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3875 - 3877
  • [30] Design and installation of a new electron cyclotron emission diagnostic antenna in LHD
    Tsuchiya, Hayato
    Nagayama, Yoshio
    Kawahata, Kazuo
    Inagaki, Shigeru
    Kubo, Shin
    Plasma and Fusion Research, 2011, 6 (1 SPECIAL ISSUE):