Vibration Measurement and Wave Reflection Analysis in an Electrified Railway Catenary Based on Analytical Methods

被引:2
|
作者
Duan, Fuchuan [1 ]
Liu, Zhigang [1 ]
Song, Yang [2 ]
Derosa, Stefano [2 ]
Ronnquist, Anders [2 ]
Zhai, Donghai [3 ]
机构
[1] Southwest Jiaotong Univ, Sch Elect Engn, Chengdu 610031, Peoples R China
[2] Norwegian Univ Sci & Technol, Dept Struct Engn, N-7491 Trondheim, Norway
[3] Southwest Jiaotong Univ, Dept Software Engn, Chengdu 610031, Peoples R China
关键词
Catenary; electrified railway; reflection coefficient; vibration measurement; wave decomposition; wave reflection; FINITE-ELEMENT; SYSTEM; PANTOGRAPH; SPEED; BEAM; SIMULATION; DYNAMICS; MODEL;
D O I
10.1109/TIM.2021.3063178
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The wave propagation property of the catenary directly affects the pantograph-catenary interaction performance. Specifically, wave reflection and transmission occurring at waveguide discontinuities, particularly at dropper junctions, directly impact the pantograph-catenary interaction performance. In this study, wave reflection occurring at the dropper junctions is investigated using both analytical and experimental approaches. First, a partial catenary model is established to analyze the catenary wave propagation by considering the wave reflections at the dropper junctions. The result indicates that the wave reflection in the contact wire (CW) affects the contact performance more significantly than that in the messenger wire. Two types of experimental tests are performed to analyze the wave reflection in the catenary-single CW and full-scale catenary tests. An analytical method considering back-and-forth reflections between the adjacent droppers is proposed to identify the actual reflection coefficients and extract the wave components from the measured data. The single CW test result shows that the dropper mass has a negligible influence on the wave reflection. The full-scale catenary test result indicates that the catenary reflection coefficient obtained from the measured data can match the design value with an acceptable error using the proposed method. Moreover, the measured data can be decomposed into wave components with different reflection orders, in which less energy is centered in the higher-reflection-order component. The proposed methods have been justified effective in reflection coefficient identification for the actual catenary structure.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Field measurement, analysis and protection for the vibration of an ancient ruin induced by railway
    Guangzhou University-Tamkang University Joint Research Center for Engineering Structure Disaster Prevention and Control, Guangzhou University, Guangzhou, China
    不详
    J. Vibroeng., 4 (2049-2065):
  • [22] In Situ Measurement and Analysis for Environmental Vibration Induced by Railway in Hanguguan, Luoyang
    Ye, Mao
    Ren, Min
    Yuan, Chen
    ADVANCES IN ENVIRONMENTAL VIBRATION, 2011, : 179 - 184
  • [23] Stereo Vision-Based Measurement System for Geometric Parameters of High-Speed Railway Catenary
    Zhou Wei
    Du Xinyu
    Xue Xiantang
    Li Ding
    Fu Qiang
    Zhang Yi
    Wang Qiang
    Wang Fadeng
    Ren Shengwei
    ACTA OPTICA SINICA, 2023, 43 (05)
  • [24] Power Quality Analysis System of Electrified Railway Based on PSASP and Virtual Node and Applications
    Li, Wenchen
    Xu, Shuwen
    Chen, Xinglei
    Peng, Hongying
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [25] Analysis of Vibration Reduction and Vibration Measurement for Long-Span Railway Station Floor Slab
    Yu Z.
    Hu G.
    Li T.
    Feng D.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2019, 54 (02): : 296 - 303and342
  • [26] Analysis of Vibration Characteristics of the Pantograph Catenary System Based on the Theory of Timoshenko Beam
    Qu, Zhiyong
    Yang, Yu
    Zhao, Yong
    PROCEEDINGS OF 2015 INTERNATIONAL CONFERENCE ON FLUID POWER AND MECHATRONICS - FPM 2015, 2015, : 465 - 468
  • [27] Analysis of sinusoidal and trapezoidal wave vibration adsorption methods
    Wang K.
    Li D.
    Wang W.
    Zong G.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2010, 46 (17): : 48 - 54+61
  • [28] Probabilistic Risk Analysis for Catenary System of Heavy-Haul Railway Based on Casual Inference
    Li, Xue
    Yan, Xiang
    Ma, Lan
    Li, Hong
    Wang, Huawei
    Cai, Lili
    Lu, Shuai
    Tang, Chao
    Wei, Xilian
    CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE, 2025, 37 (03):
  • [29] Analysis on dynamic characteristics of high-speed railway catenary based on wind field simulation
    Liu, Zhi-Gang
    Hou, Yun-Chang
    Han, Zhi-Wei
    Wang, Hong-Rui
    Tiedao Xuebao/Journal of the China Railway Society, 2013, 35 (11): : 21 - 28
  • [30] An analytical approach for the analysis of stress wave transmission and reflection in waveguide systems based on Timoshenko beam theory
    Farahani, Ali
    Samadzad, Mahdi
    Rafiee-Dehkharghani, Reza
    WAVE MOTION, 2024, 126