Modeling, Design, Identification of D-H Parameters and Calibration of Surgical Coordinate Measuring Mechanism

被引:0
|
作者
Bhutani, Gaurav [1 ]
Dwarakanath, T. A. [1 ]
Badodkar, D. N. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Remote Handling & Robot, Mumbai 400085, Maharashtra, India
关键词
Neuro-registration; Neuronavigation; D-H parameters; Design Calibration; Point and line coordinate measuring mechanism;
D O I
10.1007/978-981-10-8597-0_20
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A portable Surgical Coordinate Measuring Mechanism (SCMM) is designed and developed to measure the 3D coordinates of a point and a line vector passing through a point in its workspace. The synthesis of the mechanism is done to localize a neuro-anatomical reference frame with respect to the robot reference coordinate system. The SCMM is an articulated serial chain and is an important constituent of the neurosurgical suite being developed by DRHR, BARC, Mumbai. Dimensional synthesis of the SCMM is carried out by optimizing the mechanism footprint and manipulability of the neuro-registration. Design, development, calibration, and demonstration of SCMM are discussed in the paper. The paper emphasizes that the measured values of the D-H parameters are most often not practically feasible for implementation. It is shown that calibration-based methods are useful for improving the accuracy of system.
引用
收藏
页码:233 / 245
页数:13
相关论文
共 50 条
  • [31] Calibration of A 6-PRRS Parallel Manipulator Using D-H Method Combined with Vector Chain
    Yang, Yonggang
    Liu, Yubin
    Pi, Jun
    Shi, Yongsheng
    Li, Wei
    2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, : 3944 - +
  • [32] Calibration method for structural parameters of the articulated arm coordinate measuring machine utilizing a modified hybrid algorithm
    Liu, Kejin
    Liang, Yaru
    Tang, Miaomiao
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (05)
  • [33] Design of a 3-DOF Robotic Arm and Implementation of D-H Forward Kinematics
    Manolescu, Denis
    Secco, Emanuele Lindo
    THIRD CONGRESS ON INTELLIGENT SYSTEMS, CIS 2022, VOL 1, 2023, 608 : 569 - 583
  • [34] GA-Based Modified D-H Method Calibration Modelling for 6-DOFs Serial Robot
    Dong., Wenbo
    Lin, Weiyang
    Qian, Cheng
    Ye, Chao
    Gao, Huijun
    2016 31ST YOUTH ACADEMIC ANNUAL CONFERENCE OF CHINESE ASSOCIATION OF AUTOMATION (YAC), 2016, : 225 - 230
  • [35] Modeling of position and pose error of Stewart machine tool based on D-H transforming matrix
    Shan P.
    Xie L.
    Tian W.
    Wen J.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2010, 46 (17): : 186 - 191
  • [36] FUNCTIONAL WORK SPACE ESTIMATION OF A ROBOT USING FORWARD, KINEMATICS, D-H PARAMETERS, AND SHAPE ANALYSES
    Urbanic, R. J.
    Gudla, A.
    PROCEEDINGS OF THE ASME 11TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2012, VOL 3, 2012, : 381 - +
  • [37] Design of a high-precision 3D-coordinate measuring machine
    Vermeulen, M.M.P.A.
    Rosielle, P.C.J.N.
    Schellekens, P.H.J.
    CIRP Annals - Manufacturing Technology, 1998, 47 (01): : 447 - 450
  • [38] Design of a high-precision 3D-Coordinate Measuring Machine
    Vermeulen, MMPA
    Rosielle, PCJN
    Schellekens, PHJ
    CIRP ANNALS 1998 - MANUFACTURING TECHNOLOGY, VOL 47, NO 1, 1998, 47 : 447 - 450
  • [39] Characterization of dihydrogen-bonded D-H•••H-A complexes on the basis of infrared and magnetic resonance spectroscopic parameters
    Cybulski, H
    Pecul, M
    Sadlej, J
    Helgaker, T
    JOURNAL OF CHEMICAL PHYSICS, 2003, 119 (10): : 5094 - 5104
  • [40] The Parameters Calibration and Error Compensation of Circular Gratings for Parallel Double-joint Coordinate Measuring Machine(CMM)