Monitoring of dissolved reactive phosphorus in wastewaters by flow injection analysis .1. Method development and validation

被引:17
|
作者
Benson, RL
Truong, YB
McKelvie, ID
Hart, BT
机构
[1] MONASH UNIV,WATER STUDIES CTR,CAULFIELD,VIC 3145,AUSTRALIA
[2] MONASH UNIV,DEPT CHEM,CAULFIELD,VIC 3145,AUSTRALIA
关键词
flow injection; phosphorus; wastewaters; spectrophotometry;
D O I
10.1016/0043-1354(96)00008-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The optimisation and validation of a flow-injection (FI) procedure for dissolved reactive phosphorus (DRP) in wastewaters is described. The procedure is based on the formation of molybdophosphoric acid and subsequent reduction to molybdenum blue with tin(II) chloride. The limit of detection was 0.05 mg P 1(-1) and the linear range was 0-25 mg P 1(-1). Particular emphasis is placed on the suitability of the procedure for application in an automated on-line FI analyser. This includes a comprehensive examination of potential interferences in the analytical procedure and comparison of the performance of the method with two other established procedures. Temperature effects and long-term reagent stability were also examined. The results from the proposed FI procedure for DRP in 11 wastewater samples showed very good correlation with those from the standard batch procedure. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:1959 / 1964
页数:6
相关论文
共 50 条
  • [31] A reverse-flow injection analysis method for the determination of dissolved oxygen in fresh and marine waters
    Muangkaew, S
    McKelvie, ID
    Grace, MR
    Rayanakorn, M
    Grudpan, K
    Jakmunee, J
    Nacapricha, D
    TALANTA, 2002, 58 (06) : 1285 - 1291
  • [32] ANALYSIS OF WASTE-WATERS FOR POLYNUCLEAR AROMATIC-HYDROCARBONS .1. METHOD DEVELOPMENT AND VALIDATION
    BEDDING, ND
    MCINTYRE, AE
    LESTER, JN
    PERRY, R
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (12) : 597 - 605
  • [33] Development of the continuously variable volume reactor for flow injection analysis Part 1. Design, capabilities and testing
    Lipe, LL
    Purinton, SM
    Mederios, E
    Harrell, CC
    Efta, C
    Murray, M
    Wood, M
    Portier, RB
    Chalk, SJ
    ANALYTICA CHIMICA ACTA, 2002, 455 (02) : 287 - 304
  • [34] Development and validation of a precise flow injection method for the assessment of brexpiprazole, with application to pharmaceutical dosage forms and human plasma analysis
    Derayea, Sayed M.
    Zaafan, Al Amir S.
    Nagy, Dalia M.
    Oraby, Mohamed
    BMC CHEMISTRY, 2024, 18 (01)
  • [35] Development and validation of a stability indicating HPLC method for the analysis of lornoxicam in powder for injection
    Zhang, Jianjun
    Li, Li
    Gao, Yuan
    Fan, Weiming
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2012, 25 (02) : 371 - 375
  • [36] Development of a flow injection analysis method for the determination of acrylamide copolymers in brines
    Petroleum Recovery Institute, #100, 3512-33rd St. NW, Calgary, Alta. T2L 2A6, Canada
    不详
    J. Pet. Sci. Eng., 1-2 (129-139):
  • [37] Development of a flow injection analysis method for the determination of acrylamide copolymers in brines
    Taylor, KC
    Burke, RA
    Nasr-El-Din, HA
    Schramm, LL
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 1998, 21 (1-2) : 129 - 139
  • [38] Method development based on all injection analysis for the determination of phosphorus in soil and sediment extracts
    Amornthammarong, N
    Anujaravat, P
    Sereenonchai, K
    Chaisuwan, P
    Sastranurak, P
    Wilairat, P
    Nacapricha, D
    TALANTA, 2005, 68 (02) : 480 - 487
  • [39] FLOW INJECTION ANALYSES .1. NEW CONCEPT OF FAST CONTINUOUS-FLOW ANALYSIS
    RUZICKA, J
    HANSEN, EH
    ANALYTICA CHIMICA ACTA, 1975, 78 (01) : 145 - 157
  • [40] Development of flow analysis solver by finite volume method and its validation
    Kim, Myung-Hoon
    Jung, Rho-Taek
    Sung, Hong Gun
    Lew, Jae-Moon
    PROCEEDINGS OF THE SIXTEENTH (2006) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 3, 2006, : 828 - 834