Detection of sensorineural hearing loss using automated auditory brainstem-evoked response and transient-evoked otoacoustic emission in term neonates with severe hyperbilirubinaemia

被引:1
|
作者
Boo, N. Y. [1 ]
Rohani, A. J. [2 ]
Asma, A. [3 ]
机构
[1] Int Med Univ, Dept Paediat, Sch Clin, Jalan Rasah 70300, Seremban, Malaysia
[2] Univ Kebangsaan Malaysia, Dept Paediat, Fac Med, Kuala Lumpur 56000, Malaysia
[3] Univ Kebangsaan Malaysia, Dept Otorhinolaryngol, Fac Med, Kuala Lumpur 56000, Malaysia
关键词
automated auditory brainstem response; hearing loss; otoacoustic emissions; severe hyperbilirubinaemia; transient-evoked otoacoustic emissions;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: This study was designed to compare the sensitivity and specificity of detecting sensorineural hearing loss (SNHL) using the transient-evoked otoacoustic emissions (OAE) machine (the Madsen TE Echoscreen) and automated auditory brainstem response (AABR) machine (the Sabre Compac portable AABR) in term neonates exposed to severe hyperbilirubinaemia. Methods: This was a prospective study carried out over a 30-month period in a neonatal intensive care unit. Term infants (gestation equal to or greater than 37 weeks) with severe hyperbilirubinaemia (peak total serum bilirubin level equal to or greater than 300 umol/L) were recruited. Hearing tests were carried out before discharge. Results: The median age of the 250 study infants when OAE and AABR were tested, was eight days (IQR four days) and their median age when auditory brainstem-evoked response (ABR) was done was 58 days (IQR 56 days). Based on the findings of ABR, 32 (12.8 percent) infants had unilateral or bilateral SNHL. There was no significant difference in the peak total serum bilirubin levels between infants with SNHL(median 333 umol/L, IQRS7)and those without (median 340 umol/L, IQR: 58) (p-value is 0.3). The sensitivity of OAE for detecting SNHL was 15.9 percent, and its specificity 95.2 percent. The sensitivity of the Sabre Compac portable AABR machine for detecting SNHL was 40.9 percent and its specificity was 63.2 percent. Conclusion: Both the OAE machine and the Sabre AABR machine were not sensitive enough for mass screening of SNHL in infants exposed to severe hyperbilirubinaemia.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 32 条
  • [21] Comparison of hearing screening programs between one step with transient evoked otoacoustic emissions (TEOAE) and two steps with TEOAE and automated auditory brainstem response
    Lin, HC
    Shu, MT
    Lee, KS
    Ho, GM
    Fu, TY
    Bruna, S
    Lin, G
    LARYNGOSCOPE, 2005, 115 (11): : 1957 - 1962
  • [22] Identification of neonatal hearing impairment: Evaluation of transient evoked otoacoustic emission, distortion product otoacoustic emission, and auditory brain stem response test performance
    Norton, SJ
    Gorga, MP
    Widen, JE
    Folsom, RC
    Sininger, Y
    Cone-Wesson, B
    Vohr, BR
    Mascher, K
    Fletcher, K
    EAR AND HEARING, 2000, 21 (05): : 508 - 528
  • [23] Reliability of hearing screening in high-risk neonates: Comparative study of otoacoustic emission, automated and conventional auditory brainstem response
    Suppiej, A.
    Rizzardi, E.
    Zanardo, V.
    Franzoi, M.
    Ermani, M.
    Orzan, E.
    CLINICAL NEUROPHYSIOLOGY, 2007, 118 (04) : 869 - 876
  • [24] Detection of Perinatal Cytomegalovirus Infection and Sensorineural Hearing Loss in Belgian Infants by Measurement of Automated Auditory Brainstem Response
    Verbeeck, Jannick
    Van Kerschaver, Erwin
    Wollants, Elke
    Beuselinck, Kurt
    Stappaerts, Luc
    Van Ranst, Marc
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (11) : 3564 - 3568
  • [25] Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection
    Durante, Alessandra Spada
    Wieselberg, Margarita Bernal
    Roque, Nayara
    Carvalho, Sheila
    Pucci, Beatriz
    Gudayol, Nicolly
    de Almeida, Katia
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2017, 83 (02) : 147 - 154
  • [26] Detection and differentiation of sensorineural hearing loss in mice using auditory steady-state responses and transient auditory brainstem responses
    Pauli-Magnus, D.
    Hoch, G.
    Strenzke, N.
    Anderson, S.
    Jentsch, T. J.
    Moser, T.
    NEUROSCIENCE, 2007, 149 (03) : 673 - 684
  • [27] Comparison of Two-Step Transient Evoked Otoacoustic Emissions and One-Step Automated Auditory Brainstem Response for Universal Newborn Hearing Screening Programs in Remote Areas of China
    Sheng, Haibin
    Zhou, Qian
    Wang, Qixuan
    Yu, Yun
    Liu, Lihua
    Liang, Meie
    Zhou, Xueyan
    Wu, Hao
    Tang, Xiangrong
    Huang, Zhiwu
    FRONTIERS IN PEDIATRICS, 2021, 9
  • [28] Comparison of threshold estimation in infants with hearing loss or normal hearing using auditory steady-state response evoked by narrow band CE-chirps and auditory brainstem response evoked by tone pips
    Michel, Franck
    Jorgensen, Kristoffer Foldager
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2017, 56 (02) : 99 - 105
  • [29] HEARING LOSS IN TERM NEONATES WITH HYPERBILIRUBINAEMIA. FOLLOW-UP BASED ON BRAIN STEM EVOKED RESPONSE (BERA) AND OTOEMISSIONS ACUSTICS. 882
    Clery B. Gallacci
    Marina S. Figueiredo
    Abrahão Berezin
    Christiane Soncin
    Adriana Ganz
    Ana Cecilia Padula
    Pediatric Research, 1997, 41 (Suppl 4) : 149 - 149
  • [30] COST EFFECTIVENESS OF UNIVERSAL NEONATAL HEARING SCREENING WITH OTOACOUSTIC EMISSIONS AND/OR AUTOMATED AUDITORY BRAINSTEM RESPONSE, FOR THE DETECTION OF BILATERAL CONGENITAL HEARING LOSS AND EARLY TREATMENT, IN NEWBORNS WITHOUT RISK FACTORS, IN COLOMBIA
    Medina Torres, Y. A.
    Diaz Rojas, J. A.
    Gamboa Garay, O. A.
    VALUE IN HEALTH, 2017, 20 (09) : A586 - A587