A novel 4-limb earth fault compensation reactor for distribution network

被引:1
|
作者
Penttonen, Jyrki [1 ,2 ]
Lehtonen, Matti [1 ]
Muhammad, Shafiq [2 ]
机构
[1] Aalto Univ, Dept Elect Engn, Espoo, Finland
[2] Vensum Ltd, Helsinki, Finland
关键词
distribution network; earth fault compensation; reactor; resonant earthing network; transformers;
D O I
10.1002/etep.2433
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel earth fault compensation solution, which presents high positive sequence impedance and magnetically controllable zero sequence impedance. A 4-limb reactor is introduced to compensate earth fault currents in three-phase power distribution networks without the need of neutral point in substation transformer or separate earthing transformer. This results in considerably lower costs in implementing earth fault current compensation with much faster operation, making it possible to tune for 100% compensation during fault thus improving the probability of arc suppression. The presented reactor is analyzed analytically, and its performance is validated by simulations. The presented solution can significantly improve the reliability of the supply network.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Fast AC reactor-based fault current limiters application in distribution network
    Radmanesh, Hamid
    Fathi, Seyed Hamid
    HIGH VOLTAGE, 2018, 3 (03): : 232 - 243
  • [22] Central or local compensation of earth-fault currents in non-effectively earthed distribution systems
    Guldbrand, A.
    Samuelsson, O.
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1129 - 1134
  • [23] Methods for earth fault identification and distance estimation in a compensated medium voltage distribution network
    Nikander, Ari
    Jarventausta, Pertti
    Proceedings of the International Conference on Energy Management and Power Delivery, EMPD, 1998, 2 : 595 - 600
  • [24] Description of 6-35 kV lines in recognition of earth fault in a distribution network
    Lyamets Y.Y.
    Belyanin A.A.
    Russian Electrical Engineering, 2014, 85 (3) : 121 - 126
  • [25] Methods for earth fault identification and distance estimation in a compensated medium voltage distribution network
    Nikander, A
    Jarventausta, P
    PROCEEDINGS OF EMPD '98 - 1998 INTERNATIONAL CONFERENCE ON ENERGY MANAGEMENT AND POWER DELIVERY, VOLS 1 AND 2 AND SUPPLEMENT, 1998, : 595 - 600
  • [26] Study of Earth-Fault Location Method for Distribution Network Based on Transient Signal
    Huang, Zhi Chao
    Zhong, Yi
    Li, Cai Lin
    Liu, Mu
    Yang, Sheng Zhen
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT I, PTS 1-3, 2012, 105-107 : 742 - 746
  • [27] A Novel Protection Scheme for an LVDC Distribution Network With Reduced Fault Levels
    Wang, Dong
    Emhemed, Abdullah
    Burt, Graeme
    2017 IEEE SECOND INTERNATIONAL CONFERENCE ON DC MICROGRIDS (ICDCM), 2017, : 69 - 75
  • [28] A Novel DWT-ERT-based Fault Location for Distribution Network
    Rahangdale R.
    Gupta A.
    Recent Advances in Computer Science and Communications, 2024, 17 (03) : 11 - 19
  • [29] A Novel Integrated Method for Harmonic Suppression and Reactive Power Compensation in Distribution Network
    Wang, Yifei
    Yin, Kaiyang
    Liu, Huikang
    Yuan, Youxin
    SYMMETRY-BASEL, 2022, 14 (07):
  • [30] RETRACTED: Locating of the earth fault of the single-phase at the tree distribution network (Retracted Article)
    Guo, Li-Ping
    2011 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL SCIENCE-ICEES 2011, 2011, 11 : 1451 - 1455