A New Current Transducer for On-Line Monitoring of Leakage Current on HV Insulator Strings

被引:12
|
作者
Villalobos, Rodrigo J. [1 ]
Moran, Luis A. [2 ]
Huenupan, Fernando [1 ]
Vallejos, Francisco [1 ]
Moncada, Roberto [1 ]
Pesce, Cristian G. [1 ]
机构
[1] Univ La Frontera, Dept Elect Engn, Temuco 4811230, Chile
[2] Univ Concepcion, Dept Elect Engn, Concepcion 4030000, Chile
关键词
Insulators; Transducers; Leakage currents; Current measurement; Pollution measurement; Transmission line measurements; Pollution; Current transducer; HV insulator strings; leakage current; on-line monitoring; pollution level estimation; CONTAMINATION LEVEL; FLASHOVER PROCESS; CURRENT INDEX; VOLTAGE; POLLUTION; PORCELAIN;
D O I
10.1109/ACCESS.2022.3191349
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Leakage current measurement and its harmonics have been widely used for the pollution level estimation of HV insulator strings. However, the solutions available to applications into transmission lines and substations are few and it reduces the creepage distance (mm/kV), must be installed by de-energizing the electrical power system or do not allow the characteristic harmonics of the leakage current to be obtained. This paper presents the design, implementation, testing, and experimental validation of a transducer for measuring and online monitoring of leakage currents on high-voltage insulator strings. The transducer is composed of a clamp-type current transformer with a supermalloy material core. The leakage current is reconstructed from the transducer output voltage by applying the Fast Fourier Transform (FFT) and its own inverse transfer function, which allows it to obtain the leakage current with its characteristic harmonics and reduces the electromagnetic noise present in power systems. The output voltage of the transducer was acquired, processed, and transmitted using a dedicated device installed in the HV tower. The proposed transducer was first tested on an insulator inside an artificial fog chamber according to the IEC 60507 standard. The transducer was experimentally validated on an insulator string in a 220 kV substation. The results showed that the designed transducer measured the leakage current and its harmonics with an average error less than 1.76%. With these results the transducer can be used for the on-line monitoring of pollution levels of insulator strings without reduces the creepage distance.
引用
收藏
页码:78818 / 78826
页数:9
相关论文
共 50 条
  • [41] Development of a humidity controllable insulator leakage current intelligent monitoring and controllable system
    Wang, Li-Ming
    Jiang, Xin-Bin
    Guan, Zhi-Cheng
    Dai, Han-Qi
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (08): : 1950 - 1956
  • [42] Frequency Analysis and Recurrent Plot of the Leakage Current to Monitoring the Insulator Surface State
    Maadjoudj, D.
    Mekhaldi, A.
    Teguar, M.
    2018 IEEE 2ND INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), 2018,
  • [43] Nonintrusive insulator leakage current monitoring system based on fiber optic transmission
    Lv Jianxun
    Guo Xin
    Yuan Haiwen
    Liu Yuanqing
    2015 FIFTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2015, : 885 - 889
  • [44] Influence of power system's harmonic voltage and interphase interference to on-line resistive leakage current monitoring of MOA
    Wang Yongqiang
    Lu Fangcheng
    Shang Jing
    Li Heming
    CEEM' 2006: ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, VOLS 1 AND 2, PROCEEDINGS, 2006, : 620 - +
  • [45] Fiber-optic sensor system for leakage current detection on insulator strings of overhead transmission lines
    Oliveira, SC
    Fontana, E
    Cavalcanti, FJMM
    Lima, RB
    Martins, JF
    Meneses-Pacheco, E
    2005 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE (IMOC), 2005, : 466 - 471
  • [46] Research on Icing Flashover Test Methods and Leakage Current Analysis of Full-scaled Insulator Strings
    Liu, Bo
    Yu, Xinzhe
    Su, Zhiyi
    Zhou, Jun
    Xu, Yueneng
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 378 - 381
  • [47] Space charge distribution and leakage current pulses for contaminated glass insulator strings in power transmission lines
    Othman, Nordiana Azlin
    Piah, Mohamed Afendi Mohamed
    Adzis, Zuraimy
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (04) : 876 - 882
  • [48] Identifying faulty insulator strings by detecting insulator corona pulse current
    Li, CR
    Shi, Q
    Cheng, YC
    Lin, G
    Huang, XQ
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 529 - 532
  • [49] On-line temperature monitoring in insulation material for HV devices
    Gao, LG
    Jin, LJ
    Wang, ZK
    Lv, CS
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 118 - 121
  • [50] Insulator cuts leakage current in MSM detector
    不详