A New Current Transducer for On-Line Monitoring of Leakage Current on HV Insulator Strings

被引:12
|
作者
Villalobos, Rodrigo J. [1 ]
Moran, Luis A. [2 ]
Huenupan, Fernando [1 ]
Vallejos, Francisco [1 ]
Moncada, Roberto [1 ]
Pesce, Cristian G. [1 ]
机构
[1] Univ La Frontera, Dept Elect Engn, Temuco 4811230, Chile
[2] Univ Concepcion, Dept Elect Engn, Concepcion 4030000, Chile
关键词
Insulators; Transducers; Leakage currents; Current measurement; Pollution measurement; Transmission line measurements; Pollution; Current transducer; HV insulator strings; leakage current; on-line monitoring; pollution level estimation; CONTAMINATION LEVEL; FLASHOVER PROCESS; CURRENT INDEX; VOLTAGE; POLLUTION; PORCELAIN;
D O I
10.1109/ACCESS.2022.3191349
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Leakage current measurement and its harmonics have been widely used for the pollution level estimation of HV insulator strings. However, the solutions available to applications into transmission lines and substations are few and it reduces the creepage distance (mm/kV), must be installed by de-energizing the electrical power system or do not allow the characteristic harmonics of the leakage current to be obtained. This paper presents the design, implementation, testing, and experimental validation of a transducer for measuring and online monitoring of leakage currents on high-voltage insulator strings. The transducer is composed of a clamp-type current transformer with a supermalloy material core. The leakage current is reconstructed from the transducer output voltage by applying the Fast Fourier Transform (FFT) and its own inverse transfer function, which allows it to obtain the leakage current with its characteristic harmonics and reduces the electromagnetic noise present in power systems. The output voltage of the transducer was acquired, processed, and transmitted using a dedicated device installed in the HV tower. The proposed transducer was first tested on an insulator inside an artificial fog chamber according to the IEC 60507 standard. The transducer was experimentally validated on an insulator string in a 220 kV substation. The results showed that the designed transducer measured the leakage current and its harmonics with an average error less than 1.76%. With these results the transducer can be used for the on-line monitoring of pollution levels of insulator strings without reduces the creepage distance.
引用
收藏
页码:78818 / 78826
页数:9
相关论文
共 50 条
  • [1] On-line leakage current monitoring of 400 kV insulator strings in polluted areas
    Instituto de Investigaciones, Electricas, Mexico
    IEE Proc Gener Transm Distrib, 6 (560-564):
  • [2] On-line leakage current monitoring of 400 kV insulator strings in polluted areas
    FierroChavez, JL
    RamirezVazquez, I
    MontoyaTena, G
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (06) : 560 - 564
  • [3] On-line Monitoring System of Insulator Leakage Current Based on ARM
    Zuo Tingtao
    Liu Tianyu
    Chen Ke
    Hu Xiaoguang
    2012 10TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL INFORMATICS (INDIN), 2012, : 75 - 79
  • [4] On-line Monitoring System of Insulator Leakage Current Based on ARM
    Zuo Tingtao
    Liu Tianyu
    Chen Ke
    Hu Xiaoguang
    2011 6TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2011, : 365 - 369
  • [5] A new broadband microcurrent transducer for insulator leakage current monitoring system
    Chen, Weigen
    Yao, Chenguo
    Chen, Pan
    Sun, Caixin
    Du, Lin
    Liao, Ruijin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) : 355 - 360
  • [6] On-line monitoring of HV bushings and current transformers
    Berler, Z
    Sokolov, V
    Prikhodko, V
    Bates, D
    Proceedings: Electrical Insulation Conference and Electrical Manufacturing Conference, 2005, : 61 - 66
  • [7] On-line monitoring system on measuring leakage current near HV side for electrical transmission line insulators
    Zhao, Hanbiao
    Lin, Hui
    Xie, Lili
    Deng, Zhenglong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2004, 28 (22): : 78 - 82
  • [8] A new on-line leakage current monitoring system of ZnO surge arresters
    Lee, BH
    Kang, SM
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 2005, 119 (01): : 13 - 18
  • [9] Influence of interphase interference to on-line leakage current monitoring of MOA
    Wang, YQ
    Lu, FC
    Li, HM
    2004 4th INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, 2004, : 916 - 919
  • [10] Real time monitoring of the leakage current of 230 kV insulator strings under washing
    Oliveira, S. Campello
    Fontana, Eduardo
    Cavalcanti, F. J. M. M.
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 798 - +