Application of an automatic, uncertainty model-guided, target-generating algorithm to lung stereotactic body radiotherapy

被引:0
|
作者
Yock, Adam D. [1 ]
Knutson, Ashley [1 ]
Osmundson, Evan [1 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Radiat Oncol, Nashville, TN USA
关键词
margins; motion management; probabilistic target; INTENSITY-MODULATED RADIOTHERAPY; GEOMETRICAL UNCERTAINTIES; SETUP ERRORS; NECK-CANCER; MARGINS; PROSTATE; HEAD; STRATEGIES; MOTION; VOLUME;
D O I
10.1002/mp.15323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This work evaluated a new radiotherapy target-generating framework (the alpha Target algorithm) for creating internal target volumes for lung SBRT. Methods Nineteen patients previously treated with definitive intent SBRT to the lung were identified from a clinical database. For each patient's 4DCT simulation scan, deformable image registration was used between phases of the scan in order to generate voxelized models of motion for 35 individual gross tumor volumes. These motion models were then used with a new implementation of a previously described target-generating algorithm to create new internal target volumes (alpha ITVs). The resulting alpha ITVs were analyzed with respect to their volume and the coverage they provided each tumor voxel per that voxel's motion model. The clinically used ITVs were similarly analyzed, and were then compared to the alpha ITVs using paired Student's t-tests. In addition, isotropic margins were added to the alpha ITVs in order to determine the largest margin magnitude that could be added without exceeding the volume of the clinical ITVs. Results The alpha ITVs increased the target coverage provided to each tumor's 5th-percentile-most-covered-voxel an average of 50.3% compared to the clinical ITVs (p < 0.0001). At the same time, the alpha ITVs had volumes that were, on average, 31.4% smaller (p < 0.0001). The differences in volume were large enough that, on average, an extra 2 mm isotropic margin could be added to the alpha ITV before it had a volume greater than the clinical ITV. Conclusions The alpha Target algorithm can generate more effective lung SBRT internal target volumes that provide greater coverage with smaller volumes. In combination with numerous other advantages of the framework, this effectiveness makes the alpha Target algorithm a powerful new method for advanced IGRT or adaptive radiotherapy techniques.
引用
收藏
页码:7623 / 7631
页数:9
相关论文
共 50 条
  • [41] A STUDY ON TARGET POSITIONING ERROR AND ITS IMPACT ON DOSE VARIATION IN IMAGE-GUIDED STEREOTACTIC BODY RADIOTHERAPY FOR THE SPINE
    Kim, Siyong
    Jin, Hosang
    Yang, Huey
    Amdur, Robert J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05): : 1574 - 1579
  • [42] Intrafraction target shift comparison using two breath-hold systems in lung stereotactic body radiotherapy
    Prado, Alejandro
    Zucca, Daniel
    De la Casa, Miguel Angel
    Marti, Jaime
    Alonso, Leyre
    de Acilu, Paz Garcia
    Garcia, Juan
    Hernando, Ovidio
    Fernandez-Leton, Pedro
    Rubio, Carmen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 57 - 62
  • [43] Radiation dosimetric influence by different target volume definition in Cyberknife lung cancer and abdomen stereotactic body radiotherapy
    Zhou, Han
    Li, Yikun
    Li, Jing
    Wu, Tiancong
    Chen, Ying
    Shen, Zetian
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2021, 14 (01) : 336 - 343
  • [44] Lung cancer stereotactic body radiotherapy: The dosimetric effect of heterogeneity correction on normal tissue tolerances and target coverage
    Franks, K.
    Bissonnette, J-P.
    Purdie, T.
    Jaffray, D.
    Cho, J.
    Payne, D.
    Sun, A.
    Kane, G.
    Pearson, S.
    Bezjak, A.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S487 - S488
  • [45] Clinical Application of Dibh Amplitude Gated Technique for Stereotactic Body Radiotherapy (SBRT) Lung and Liver Oligometastases
    Bhatt, C. P.
    Ahmad, I.
    Chufal, K. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E746 - E746
  • [46] The impact of 4DCT-ventilation imaging-guided proton therapy on stereotactic body radiotherapy for lung cancer
    Ieko, Yoshiro
    Kadoya, Noriyuki
    Kanai, Takayuki
    Nakajima, Yujiro
    Arai, Kazuhiro
    Kato, Takahiro
    Ito, Kengo
    Miyasaka, Yuya
    Takeda, Ken
    Iwai, Takeo
    Nemoto, Kenji
    Jingu, Keiichi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (03) : 230 - 237
  • [47] Image guided stereotactic body radiotherapy for early stage non-small cell lung cancer - the importance of dose
    Taremi, Mojgan M.
    Pearson, Shannon
    Fung, Sharon
    Bissonnette, Jean-Pierre
    Purdie, Tomas
    Franks, Kevin
    Brade, Anthony
    Cho, John
    Hope, Andrew
    Sun, Alex
    Bezjak, Andrea
    JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S337 - S338
  • [48] INTRAFRACTION VARIATION OF MEAN TUMOR POSITION DURING IMAGE-GUIDED HYPOFRACTIONATED STEREOTACTIC BODY RADIOTHERAPY FOR LUNG CANCER
    Shah, Chirag
    Grills, Inga S.
    Kestin, Larry L.
    McGrath, Samuel
    Ye, Hong
    Martin, Shannon K.
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1636 - 1641
  • [49] The impact of 4DCT-ventilation imaging-guided proton therapy on stereotactic body radiotherapy for lung cancer
    Yoshiro Ieko
    Noriyuki Kadoya
    Takayuki Kanai
    Yujiro Nakajima
    Kazuhiro Arai
    Takahiro Kato
    Kengo Ito
    Yuya Miyasaka
    Ken Takeda
    Takeo Iwai
    Kenji Nemoto
    Keiichi Jingu
    Radiological Physics and Technology, 2020, 13 : 230 - 237
  • [50] STEREOTACTIC BODY RADIOTHERAPY FOR PRIMARY LUNG CANCER AT A DOSE OF 50 GY TOTAL IN FIVE FRACTIONS TO THE PERIPHERY OF THE PLANNING TARGET VOLUME CALCULATED USING A SUPERPOSITION ALGORITHM
    Takeda, Atsuya
    Sanuki, Naoko
    Kunieda, Etsuo
    Ohashi, Toshio
    Oku, Yohei
    Takeda, Toshiaki
    Shigematsu, Naoyuki
    Kubo, Atsushi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02): : 442 - 448