Diffusion-weighted MRI of breast lesions: a prospective clinical investigation of the quantitative imaging biomarker characteristics of reproducibility, repeatability, and diagnostic accuracy

被引:49
|
作者
Spick, Claudio [1 ]
Bickel, Hubert [1 ]
Pinker, Katja [1 ]
Bernathova, Maria [1 ]
Kapetas, Panagiotis [1 ]
Woitek, Ramona [1 ]
Clauser, Paola [1 ]
Polanec, Stephan H. [1 ]
Rudas, Margaretha [2 ]
Bartsch, Rupert [3 ]
Helbich, Thomas H. [1 ]
Baltzer, Pascal A. [1 ]
机构
[1] Med Univ Vienna, Div Mol & Gender Imaging, Dept Biomed Imaging & Image Guided Therapy, Waehringer Guertel 18-20A, A-1090 Vienna, Austria
[2] Med Univ Vienna, Clin Inst Pathol, Waehringer Guertel 18-20A, A-1090 Vienna, Austria
[3] Med Univ Vienna, Div Oncol, Dept Internal Med, Waehringer Guertel 18-20A, A-1090 Vienna, Austria
关键词
breast cancer; diagnostic accuracy; diffusion-weighted imaging; DWI; quantitative imaging biomarker; repeatability; reproducibility; COEFFICIENT ADC MEASUREMENTS; ONCOLOGY DRUG DEVELOPMENT; 7; T; CONTRAST; CANCER; TUMORS; METAANALYSIS; DWI;
D O I
10.1002/nbm.3596
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Diffusion-weighted MRI (DWI) provides insights into tissue microstructure by visualization and quantification of water diffusivity. Quantitative evaluation of the apparent diffusion coefficient (ADC) obtained from DWI has been proven helpful for differentiating between malignant and benign breast lesions, for cancer subtyping in breast cancer patients, and for prediction of response to neoadjuvant chemotherapy. However, to further establish DWI of breast lesions it is important to evaluate the quantitative imaging biomarker (QIB) characteristics of reproducibility, repeatability, and diagnostic accuracy. In this intra-individual prospective clinical study 40 consecutive patients with suspicious findings, scheduled for biopsy, underwent an identical 3T breast MRI protocol of the breast on two consecutive days (> 24 h). Mean ADC of target lesions was assessed (two independent readers) in four separate sessions. Reproducibility, repeatability, and diagnostic accuracy between examinations (E1, E2), readers (R1, R2), and measurements (M1, M2) were assessed with intraclass correlation coefficients (ICCs), coefficients of variation (CVs), Bland-Altman plots, and receiver operating characteristic (ROC) analysis with calculation of the area under the ROC curve (AUC). The standard of reference was either histopathology (n = 38) or imaging follow-up of up to 24 months (n = 2). Eighty breast MRI examinations (median E1-E2, 2 +/- 1.7 days, 95% confidence interval (CI) 1-2 days, range 1-11 days) in 40 patients (mean age 56, standard deviation (SD) +/- 14) were evaluated. In 55 target lesions (mean size 25.2 +/- 20.8 (SD) mm, range 6-106 mm), mean ADC values were significantly (P < 0.0001) higher in benign (1.38, 95% CI 1.27-1.49 x 10(-3) mm(2)/s) compared with malignant (0.86, 95% CI 0.81-0.91 x 10-3 mm2/s) lesions. Reproducibility and repeatability showed high agreement for repeated examinations, readers, and measurements (all ICCs > 0.9, CVs 3.2-8%), indicating little variation. Bland-Altman plots demonstrated no systematic differences, and diagnostic accuracy was not significantly different in the two repeated examinations (all ROC curves > 0.91, P > 0.05). High reproducibility, repeatability, and diagnostic accuracy of DWI provide reliable characteristics for its use as a potential QIB, to further improve breast lesion detection, characterization, and treatment monitoring of breast lesions.
引用
收藏
页码:1445 / 1453
页数:9
相关论文
共 50 条
  • [21] Diffusion tensor imaging on 3-T MRI breast: diagnostic performance in comparison to diffusion-weighted imaging
    Abdelhady, Dalia
    Abdelbary, Amany
    Afifi, Ahmed H.
    Abdelhamid, Alaa-eldin
    Hassan, Hebatallah H. M.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [22] Diffusion tensor imaging on 3-T MRI breast: diagnostic performance in comparison to diffusion-weighted imaging
    Dalia Abdelhady
    Amany Abdelbary
    Ahmed H. Afifi
    Alaa-eldin Abdelhamid
    Hebatallah H. M. Hassan
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [23] Tissue Characteristics of Endometrial Carcinoma Analyzed by Quantitative Synthetic MRI and Diffusion-Weighted Imaging
    Wang, Yiang
    He, Mengge
    Cao, Peng
    Ip, Philip P. C.
    Lin, Chien-Yuan
    Liu, Weiyin
    Lee, Chia-Wei
    Lee, Elaine Y. P.
    DIAGNOSTICS, 2022, 12 (12)
  • [24] Diffusion-weighted Imaging Improves the Diagnostic Accuracy of Conventional 3.0-T Breast MR Imaging
    El Khouli, Riham H.
    Jacobs, Michael A.
    Mezban, Sarah D.
    Huang, Peng
    Kamel, Ihab R.
    Macura, Katarzyna J.
    Bluemke, David A.
    RADIOLOGY, 2010, 256 (01) : 64 - 73
  • [25] Insights Into Quantitative Diffusion-Weighted MRI for Musculoskeletal Tumor Imaging
    Subhawong, Ty K.
    Jacobs, Michael A.
    Fayad, Laura M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (03) : 560 - 572
  • [26] Comparing diagnostic accuracy of luminal water imaging with diffusion-weighted and dynamic contrast-enhanced MRI in prostate cancer: A quantitative MRI study
    Sabouri, Shirin
    Chang, Silvia D.
    Goldenberg, S. Larry
    Savdie, Richard
    Jones, Edward C.
    Black, Peter C.
    Fazli, Ladan
    Kozlowski, Piotr
    NMR IN BIOMEDICINE, 2019, 32 (02)
  • [27] The Usefulness of Diffusion-Weighted Imaging in MRI Test for Breast Cancer
    Jae-Hwan Cho
    Hae-Kag Lee
    Kyung-Rae Dong
    Woon-Kwan Chung
    Seon-Chil Kim
    Tae-Jeong Ji
    Applied Magnetic Resonance, 2012, 42 : 531 - 544
  • [28] The Usefulness of Diffusion-Weighted Imaging in MRI Test for Breast Cancer
    Cho, Jae-Hwan
    Lee, Hae-Kag
    Dong, Kyung-Rae
    Chung, Woon-Kwan
    Kim, Seon-Chil
    Ji, Tae-Jeong
    APPLIED MAGNETIC RESONANCE, 2012, 42 (04) : 531 - 544
  • [29] Repeatability and reproducibility of quantitative breast MRI in community imaging centers: Preliminary results
    Sorace, Anna G.
    Virostko, Jack
    Wu, Chengyue
    Jarrett, Angela M.
    Barnes, Stephanie L.
    Luci, Jeffrey
    Patt, Debra A.
    Goodgame, Boone
    Avery, Sarah
    Yankeelov, Thomas E.
    CANCER RESEARCH, 2018, 78 (04)
  • [30] Diagnostic value of synthetic diffusion-weighted imaging on breast magnetic resonance imaging assessment: comparison with conventional diffusion-weighted imaging
    Yilmaz, Ebru
    Guldogan, Nilgun
    Ulus, Sila
    Turk, Ebru Banu
    Misir, Mustafa Enes
    Arslan, Aydan
    Aribal, Mustafa Erkin
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (02): : 91 - 98