Sensitivity enhancement of a conventional gold grating assisted surface plasmon resonance sensor by using a bimetallic configuration

被引:33
|
作者
Bijalwan, Ashish [1 ]
Rastogi, Vipul [1 ]
机构
[1] Indian Inst Technol, Dept Phys, Roorkee 247667, Uttar Pradesh, India
关键词
COUPLED-WAVE ANALYSIS; PERFORMANCE;
D O I
10.1364/AO.56.009606
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A surface plasmon resonance (SPR)-based refractive index sensor using a silver grating fabricated over the gold film is proposed. The performance of the sensor has been evaluated on the basis of sensitivity, full width half maximum (FWHM), and dip strength of the reflection spectrum. Rigorous coupled wave analysis has been utilized to study the effect of grating parameters on sensing performance. Our systematic analysis exhibits that inappropriate grating parameters may lead to poor performance of the sensor. Sensitivity of the conventional gold grating (grating engraved in gold) assisted SPR sensor is obtained to be 321 degrees/RIU. Further, we have shown that sensitivity and FWHM could be improved by using a bimetallic structure that consists of a silver grating on a thin gold film and thereby increases the quality factor. Sensitivity of the proposed structure is 346 degrees/RIU with a quality factor more than 97.46 RIU-1. (C) 2017 Optical Society of America
引用
收藏
页码:9606 / 9612
页数:7
相关论文
共 50 条
  • [21] Theoretical investigation of voltage sensitivity enhancement for surface plasmon resonance based optical fiber sensor with a bimetallic layer
    Huang, Yu
    Xia, Liangping
    Wei, Wei
    Chuang, Chin-Jung
    Du, Chunlei
    OPTICS COMMUNICATIONS, 2014, 333 : 146 - 150
  • [22] Theoretical investigation of voltage sensitivity enhancement for surface plasmon resonance based optical fiber sensor with a bimetallic layer
    Huang, Yu
    Xia, Liangping
    Wei, Wei
    Chuang, Chin-Jung
    Du, Chunlei
    Optics Communications, 2014, 333 : 146 - 150
  • [23] Sensitivity Enhancement Using Surface Plasmon Resonance Sensor for Colorectal Detection by Employing Heterostructure
    Kalpana, N.
    Alodhayb, Abdullah N.
    Pandiaraj, Saravanan
    Singh, Shivam
    PLASMONICS, 2025,
  • [24] Sensitivity enhancement of surface plasmon resonance sensor using continuous film metallic gratings
    Hu, Changkui
    Mao, Yumin
    Yi, Yingyan
    OPTIK, 2013, 124 (20): : 4505 - 4508
  • [25] Enhancement in sensitivity of guided-wave surface plasmon resonance sensor using graphene
    Yue, Chong
    Lang, Yaopu
    Zhou, Xinlin
    Liu, Qinggang
    2019 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: MICRO/NANO PHOTONICS: MATERIALS AND DEVICES, 2020, 11440
  • [27] Gold and Aluminum based surface Plasmon resonance biosensors: sensitivity enhancement
    Biednov, Mykola
    Lebyedyeva, Tetyana
    Shpylovyy, Pavlo
    OPTICAL SENSORS 2015, 2015, 9506
  • [28] Electric field enhancement in surface plasmon resonance bimetallic configuration based on chalcogenide prism
    Maharana, Pradeep Kumar
    Bharadwaj, Sriram
    Jha, Rajan
    JOURNAL OF APPLIED PHYSICS, 2013, 114 (01)
  • [29] Resonance Effect of Bimetallic Diffraction Grating on the Sensing Characteristics of Surface Plasmon Resonance Sensor with COMSOL Multiphysics
    Singh, Sarbjit
    Kaler, R. S.
    Sharma, Siddharth
    JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2019, 14 (05) : 669 - 674
  • [30] Surface plasmon resonance hydrogen sensor based on metallic grating with high sensitivity
    Lin, Kaiqun
    Lu, Yonghua
    Chen, Junxue
    Zheng, Rongsheng
    Wang, Pei
    Ming, Hai
    OPTICS EXPRESS, 2008, 16 (23): : 18599 - 18604